• Title/Summary/Keyword: 즉시부하

Search Result 66, Processing Time 0.029 seconds

Full mouth rehabilitation of a patient with severe periodontitis using immediate loading after computer aided flapless implant surgery (심한 치주질환을 가진 환자에서 computer aided flapless surgery와 즉시 부하를 통한 전악 구강 회복 증례)

  • Kang, Seong hun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.46-55
    • /
    • 2018
  • Oral rehabilitation of a patient having severe periodontitis with alveolar bone resorption and periodontal inflammation presents a challenge to clinicians. However, if appropriate implant placement according to the bone shape is selected, unnecessary bone grafting or soft tissue surgery can be minimized. In recent years, using cone beam CT and software, it has become possible to operate the planned position with the surgical guide made with 3D printing technology. This case was a 70 years old female patient who required total extraction of teeth due to severe periodontitis and performed a full-mouth rehabilitation with an implant - supported fixed prosthesis. During the surgery, the implant was placed in a flapless manner through a surgical guide. Immediate loading of the temporary prosthesis made by CAD/CAM method before surgery was done. Since then, we have produced customized abutments and zirconia prostheses, and have reported satisfactory aesthetic and functional recovery.

Data Management Method of Table Unit for Efficient Load in a Spatial Data Warehouse Builder (공간 데이터 웨어하우스 구축기에서 추출된 데이터의 효율적인 적재를 위한 테이블 단위의 데이터 관리 기법)

  • Kim, Hyung-Sun;You, Byeong-Seob;Park, Soon-Young;Lee, Jae-Dong;Bae, Hae-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.79-81
    • /
    • 2005
  • 공간 데이터 웨어하우스 구축기는 운영 데이터베이스의 데이터를 추출하여, 공간 데이터 웨어하우스 서버에 적재하는 과정을 효율적으로 관리하는 시스템이다. 구축기는 적재로 인한 서버의 부하를 줄이기 위하여 적재할 데이터를 임시 저장하는데, 기존 기법은 적재할 데이터를 하나의 저장 공간에 관리한다. 따라서 서버가 특정 차원 테이블에 대한 실시간 질의처리를 위해 특정 차원 테이블의 즉시 적재를 요청할 경우, 구축기는 이를 위해 임시 저장한 모든 데이터를 검색하므로 처리비용이 증가한다. 또한, 하나의 저장공간에 적재할 데이터를 유지하여 서버에 데이터 적재 시, 저장을 위해 혼합된 데이터를 분석하는 비용이 증가한다. 본 논문에서는 공간 데이터 웨어하우스 구축기에서 추출된 데이터의 효율적인 적재를 위한 테이블 단위의 데이터 관리 기법을 제안한다. 제안 기법은 운영 데이터베이스로부터 추출한 데이터를 서버에 적재할 차원 테이블 단위로 구축기에서 각각 다른 저장 공간에 관리한다. 따라서 테이블 단위의 데이터 관리로 실시간 질의처리를 위한 특정 차원 테이블의 즉시 적재 비용이 감소하며, 테이블 단위의 병렬전송이 가능하여 전송비용이 감소한다. 또한, 서버로 전송된 데이터는 테이블 단위의 벌크 삽입이 가능하여 적재시간이 감소한다.

  • PDF

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Immediate effects of cigarette smoking on exercise in young adult smokers (젊은 성인 흡연자에게 흡연이 운동능에 미치는 즉시효과)

  • Park, In Won;Koh, Hyung Ki;Kang, Yoon Jung;Choi, Jae Sun;Yoo, Jee Hoon;Shin, Jong Wook;Lim, Seong-Yong;Choi, Byoung Whui;Seo, Seung Cheon;Na, Moon Jun;Hue, Sung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Background : Although the long term adverse effects of cigarette smoking on health are well known, the acute possible detrimental effects of smoking on pulmonary or cardiovascular function, especially when these systems are stressed by the metabolic demands of exercise, have not been well studied The purpose of this study is to determine the acute action of cigarette smoking on cardiopulmonary function under stress. Method : Twenty -one healthy smoking subjects were studied. Before exrecise testing, history taking, physical examination and baseline studies, including CBC, chest PA, PFT and EKG, were done. The subjects performed an incremental bicycle exercise test to exhaustion on two occasions, one without smoking and the other after smoking 5 cigarettes/h for 2 hours. All indices of P.F.T. and bicycle ergometry were compared between before and after smoking. Results : 1. $VO_2$max and $O_2$ pulse showed significant decrease in smoking day. 2. Although there were no significant differences, anaerobic threshold showed a tendency of decrease and HRmax showed that of increase in smoking day. 3. P.F.T. and respiratory indices showed no significant change io smoking day. Conclusion : Cigarette smoking has immediate adverse effect, especially on the cardiovascular system rather than the respiratory system. These results would be due to the effect of elevated HbCO and/or impaired blood flow in response to the exercise stimulus.

  • PDF

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

Comparative analysis of immediate functional loading and conventional loading about implant survival rate in the completely edentulous: Retrospective study (완전 무치악에서 즉시 부하시와 표준 부하시 임플란트 생존율에 대한 비교 분석: 후향적 연구)

  • Seo, Hyun-Soo;Park, Jun-Woo;Hong, Soon-Min;Lee, Seok-Ryun
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.771-782
    • /
    • 2014
  • Introduction: This study researched the clinical application of immediate functional loading technique about implant survival rate in the completely edentulous and suggested our protocol about surgical & prosthetic procedure. Materials and methods: 32 consecutive patients participated in this study. A total of 242 implants were inserted. In test group, 144 implants were inserted in 19 patients with immediate functional loading with occlusal contact. In control group, 98 implants were inserted in 13 patients and conventional loading was done after 4~6 months. Result: In the immediately loaded implants group, overall cumulative survival rate was 98.6%.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Development of High Efficiency Self Diagnosis Type Neon Transformer using Groin Direction of Non-Oriented Silicon Steel Strip (압연 방향을 적용한 자체 진단형 고효율 네온관용 변압기)

  • 변재영;김윤호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and grain direction of non-oriented silicon steel strip. A protection circuit is designed for all types of neon transformer loaded with one or more neon tubes. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the electronic type protection circuit will be initiated to avoid more critical hazards. These neon transformers need a electronic type protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut on when the abnormal condition occurs, preventing waste of no-load power.

Interchange Algorithm for VoD System (VOD 시스템에서의 Interchange Agent 운영 알고리즘)

  • Kang, Seok-Hoon;Park, Su-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1847-1854
    • /
    • 2005
  • This paper proposes a approach to configure efficient video-on-demand system by introducing Multicast and Cache Video-on-Demand (MCVoD) system. As a key element or the MCVoD system, interchange agent provides this system with multicasting and switching functions. With the multicasting, the MCVoD system is able to reduce the load on the network as well as VoD servers by transmitting only one video request instead of sending multiple requests on a same video stream. The switching enables clients to receive the lust stream of requested video streams instantly without waiting time and also allows avoiding undesirable duplication of video streams in the system. With various experiment results through simulation about waiting tine and cache hit ratio, we show that the MCVoD system employing the interchange agent provides better performance than current uni-proxy based system.

Power System Restoration Plan for Korea Power System (우리나라 전계통 정전시 복구계획 소개)

  • Song, Tae-Yong;Rju, Hyun-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.5-6
    • /
    • 2007
  • 우리나라는 전계통 정전 발생 및 광역지역 정전에 대비하여 매년 "전계통 정전시 복구계획"을 수립하여 정전발생에 대비하고 있다. 우리나라는 외부와 고립된 계통으로 외부수전이 불가능하므로 전국 7개 지역에 12개 자체기동발전기를 지정하여 운영하고 있다. 정전 발생시 우리나라 계통복구 절차를 살펴보면 먼저 거래소가 EMS와 전국 발 변전소로부터 올라온 정보를 분석하여 광역정전 여부를 파악하여 정전상황을 각 사업소에 통보하게 된다. 그 후 즉시 자체기동발전기를 기동하고, 시송전 선로를 구성하게 된다. 이 시송전선로를 통해 자체기동발전기에서 생산한 전력을 우선공급발전소에 전달하여 최초 계통복구를 위한 시송전계통을 구성하게 된다. 이후 안정후공급발전기에 기동전력을 공급하면서 계통에 병입되는 전력에 맞춰 계통 부하복구를 시행하게 된다. 지역별 계통이 안정화되었을 경우 지역간 계통을 연계하여 복구과정을 마치게 된다. 이러한 복구계획의 시초가 되는 자체기동발전기가 우리나라와 같은 고립계통에서 매우 중요하므로 자체기동발전기 정기시험을 매년 시행하고 있다. 마지막으로 2006년 제주계통 정전시 복구계획 적용사례와 이때 발생되었던 문제점 및 해결방안을 설명하였다.

  • PDF