• Title/Summary/Keyword: 중첩선

Search Result 214, Processing Time 0.027 seconds

Hard and soft tissue profile changes following anterior subapical osteotomy in bimaxillary dentoalveolar protrusion patients (양악성 치조 전돌 환자의 근첨하 분절 골절단술 후 경조직 및 연조직 측모 변화)

  • Han, Un-Ae;Kim, Jeong-Hwan;Yoon, Tae-Ho;Park, Je-Uk;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.475-483
    • /
    • 2003
  • The purpose of this study is to evaluate hard and soft tissue changes following the subapical osteotomy in bimaxillary dentoalveolar protrusion patients requiring maximal retraction adult female patients was selected. Surgical procedures were performed by the same surgeon, anterior subapical osteotomy techniques were employed on the maxilla and cephalometric radiograms were traced and superimposed using the best-fit method and two reference The results were as follows 1. The bodily movement of the maxillary anterior segment was achieved in a posterior moved posteriorly with a slight correction of the lower incisors. 2. The horizontal soft tissue measurements changed significantly after treatment, but Nt and Sn vertical soft tissue measurements indicated that Ls moved inferiorly and Li superiorly. 3. The correlation between hard and soft tissue changes indicated that ${\Delta}HId/{\Delta}HLi,\;{\Delta}HId/{\Delta}LL-Eline,\;{\Delta}Hpt.B/{\Delta}HILS,\;and\;{\Delta}UI-FH/{\Delta}NL$ were significant. 4. More lower lip relative to upper lip retraction was demonstrated in relation to Rickett's E-line. The ratio between upper lip displacement was $50\%$, and between the lower incisor and lower lip displacement was $60\%$. We conclude from the results that the anterior subapical osteotomy is an efficient treatment severe dentoalveolar protrusion and desire rapid results.

Debris Flow Analysis of Landslide Area in Inje Using GIS (GIS를 이용한 인제 산사태발생지역의 토석류 분석)

  • Kim, Gi-Hong;Yune, Chan-Young;Lee, Hwan-Gil;Hwang, Jae-Seon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • From 12 to 16 July 2006, 4 days' torrential rainfall in Deoksan-ri, Inje-up, Inje-gun, Gangwon-do caused massive landslide and debris flow. Huge losses of both life and property, including two people buried to death in submerged houses, resulted from this disaster. As the affected region is mostly mountainous, it was difficult to approach the region and to estimate the exact extent of damage. But using aerial photographs, we can define the region and assess the damage quickly and accurately. In this study the debris flow region in inje, Gangwon-do was analyzed using aerial photographs. This region was divided into three sections - beginning section, flow section and sedimentation section. Informations for each section were extracted by digitizing the shot images with visual reading. Topographic, forest physiognomic and soil characteristics and debris flow occurrences of this region were analyzed by overlaying topographic map, forest type map and soil map using GIS. Comprehensive analysis shows that landslide begins at slope of about $36^{\circ}$, flows down at $26^{\circ}$ slope, and at $21^{\circ}$ slope it stops flowing and deposits. Among forest physiognomic factors, species of trees showd significant relationship with debris flow. And among soil factors, effective soil depth, soil erosion class, and parent materials showed meaningful relationship with debris flow.

Management of Construction Fields Information Using Low Altitude Close-range Aerial Images (저고도 근접 항공영상을 이용한 현장정보관리)

  • Cho, Young Sun;Lim, No Yeol;Joung, Woo Su;Jung, Sung Heuk;Choi, Seok Keun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.551-560
    • /
    • 2014
  • Compare to other industrial sites, the civil construction work not only takes longer time but also has made of complicated processes, such as the integrated management, process control, and quality control until the completion. However, it is hard to take control the construction sites, since numerous issues are always emerged. The study purposes on providing the dataset to synthetically manage and monitor the civil construction site, main design, drawings, process, construction cost, and others at real-time by using the low altitude close-range aerial images, based on UAV, and the GPS surveying method for treating the three-dimensional spatial information quickly and accurately. As a result, we could provide the latest information for the quick decision-making following from planning to completion of the construction, and objective site evaluation by the high-resolution three-dimensional spatial information and drawings. Also, the present map, longitudinal map, and cross sectional view are developed to provide various datasets rapidly, such as earthwork volume table, specifications, and transition of ground level.

Development of a Verification Tool in Radiation Treatment Setup (방사선치료 시 환자자세 확인을 위한 영상 분석 도구의 개발)

  • 조병철;강세권;한승희;박희철;박석원;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2003
  • In 3-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), many studies on reducing setup error have been conducted in order to focus the irradiation on the tumors while sparing normal tissues as much as possible. As one of these efforts, we developed an image enhancement and registration tool for simulators and portal images that analyze setup errors in a quantitative manner. For setup verification, we used simulator (films and EC-L films (Kodak, USA) as portal images. In addition, digital-captured images during simulation, and digitally-reconstructed radiographs (DRR) can be used as reference images in the software, which is coded using IDL5.4 (Research Systems Inc., USA). To improve the poor contrast of portal images, histogram-equalization, and adaptive histogram equalization, CLAHE (contrast limited adaptive histogram equalization) was implemented in the software. For image registration between simulator and portal images, contours drawn on the simulator image were transferred into the portal image, and then aligned onto the same anatomical structures on the portal image. In conclusion, applying CLAHE considerably improved the contrast of portal images and also enabled the analysis of setup errors in a quantitative manner.

  • PDF

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.

Improvement of Multi-beam Echo Sounder's Depth Accuracy (다중빔 음향측심기 수심 정확도 개선)

  • Choi Chul Eung;Kim Youn Soo;Suh Yong Cheol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Multi-beam echo sounder is more precise and efficient than single beam echo sounder relatively because it is able to survey a wide area with 3 times or 4 times swath width as much as the depth of water using multi-beam echo sounder. It is sure to be needed to control supplementary equipment accurately, however, because the principle of creation and measurement of the beam is elaborate and influenced a great deal by vessel's motion. We analyzed using visual and statistical methods in both sections of the depth of water where were the places of the center of the beam and ± 45° angles from the central beam to improve the precise of Multi-beam echo sounder in this study. In result, it was required to control supplementary equipment because of errors from the vibration of an inertia governor and misalignment of extra units. Therefore, we reduced the vibration from the vessel's engine by sticking rubbers to the inertia governor and measured the offset values of extra units accurately, converted them to the values of horizontal position and lined up. In result, the precise in sounding the depth at the place of ± 45° from the center of the beam was improved from the level of the 1st order to the special order in a hydrographic survey of the IHO S44 standards and a phenomenon of ripple patterns in the overlapped area by misalignment was decreased remarkably.

Study of the determination of 226Ra in soil using liquid scintillation counter (액체섬광계수기를 이용한 토양 중 226Ra 분석 방법 연구)

  • Jung, Yoonhee;Kim, Hyuncheol;Chung, Kun Ho;Kang, Mun Ja
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • This study presented an analytical method for detecting radium in soils using a liquid scintillation counter (LSC). The isotope 226Ra was extracted from soil using the fusion method and then separated from interfering radionuclides using the precipitation method. Radium was coprecipitated as sulfate salts with barium (Ba) and then converted into Ba(Ra)CO3, which is soluble in an acidic solution. The isotope 222Rn, the decay progeny of 226Ra, was trapped in a water immiscible cocktail and analyzed by LSC. The pulse shape analysis (PSA) level was estimated using 90Sr and 226Ra standard solutions. The figure of merit was the highest at PSA 80, while the alpha spillover was the lowest at PSA 80. The counting efficiency was 243 ± 2% in a glass vial. This analytical method was verified with International Atomic Energy Agency (IAEA) reference materials, including IAEA-312, IAEA-314, and IAEA-315. The recovery ranged from 60–82%, while the relative bias between the measured value and the recommended value was less than 10%. The minimum detectable activity was 2.1 Bq kg−1 with dry mass 1 g, the background count rate of 0.02 cpm, the recovery rate of 70% and counting time of 30 min.

A New Algorithm for the Interpretation of Joint Orientation Using Multistage Convergent Photographing Technique (수렴다중촬영기법을 이용한 새로운 절리방향 해석방법)

  • 김재동;김종훈
    • Tunnel and Underground Space
    • /
    • v.13 no.6
    • /
    • pp.486-494
    • /
    • 2003
  • When the orientations of joints are measured on a rock exposure, there are frequent cases that are difficult to approach by the surveyor to the target joints or to set up scanlines on the slope. In this study, to complement such limit and weak points, a new algorithm was developed to interpret joint orientation from analyzing the images of rock slope. As a method of arranging the multiple images of a rock slope, the multistage convergent photographing system was introduced to overcome the limitation of photographing direction which existing method such as parallel stereophotogrammetric system has and to cover the range of image measurement, which is the overlapping area between the image pair, to a maximum extent. To determine camera parameters in the perspective projection equation that are the main elements of the analysis method, a new method was developed introducing three ground control points and single ground guide point. This method could be considered to be very simple compared with other existing methods using a number of ground control points and complicated analysis process. So the global coordinates of a specific point on a rock slope could be analyzed with this new method. The orientation of a joint could be calculated using the normal vector of the joint surface which can be derived from the global coordinates of several points on the joint surface analyzed from the images.

An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine (두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.273-285
    • /
    • 2000
  • The aim of this investigation was to evaluate the differences of two canti-leyer springs by using a new simulation system. This was done using a Calorific machine that compared iron uprighting spring and root uprighting spring. The Calorific machine was designed to allow observation of the whole process of tooth moving, and is composed of three parts(a temperature regulating system, electro-thermodynamic teeth, and an artificial alveolar bone component). The experiment of both mechanics were repeated five times and measured two times. The intra-examiner agreement and inlet-examiner agreement were $96.54\%\;and\;95.73\%$ and these data were statistically tested by paired t-test. The obtained results were as follows. 1. Distal and buccal movement of the anchor teeth were observed greater in the root uprighting spring than the crown uprighting spring. 2. Crown uprighting spring showed distal movement of the crown of lower second molar for 3.29mm but root uprighting spring showed only 1.68mm. 3. Crown uprighting spring exhibited forward movement of mesial and distal root of the lower second molar for 3.91mm, 3.60mm but the root uprighting spring showed 6.76mm, 6.26mm.

  • PDF

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.