• Title/Summary/Keyword: 중재적 방사선시술

Search Result 50, Processing Time 0.024 seconds

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

Reference Levels for Radiation Dose in Angiography and Interventional Radiology : In the Cerebrum (혈관 조영 검사 및 중재적 방사선 시술시 방사선량에 대한 참고 기준치 : 대뇌 중심으로)

  • Han, Jae-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The aim of this study is to compare reference levels for radiation dose in angiography and interventional radiology. Proposed reference levels for various procedures and classification of diseases are provided by fluoroscopy time and kerma area product(KAP) rate normalizing the body habitus focusing the cerebrum. Subarachnoid hemorrhage(SAH) represents the highest KAP-rates and aneurysm represents the lowest KAP-rates. According to these types of procedures, internal carotid artery(ICA), common carotid artery(CCA), and vertebral artery(VA) show the highest KAP-rates and guglielmi detachable coil shows the lowest KAP-rates. Therefore, the present study can suggested reference levels for patient radiation dose and is expected to be further useful in the field of radiation dose education and management of angiography and interventional radiology.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Reference levels for patient Radiation Dose in interventional radiological procedures (중재적 방사선 시술 시 환자선량에 대한 참고 준위 비교)

  • Park, Hyeok;Kim, Yong-Wan;Jeon, Ju-Seob
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.11-17
    • /
    • 2012
  • The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.

Study on Exposure Dose and Image Quality of Operator Using Shielding Material in Neuro Interventional Radiology (뇌혈관 중재적 시술에서 차폐체를 이용한 시술자의 피폭선량과 화질에 관한 연구)

  • Kim, Dae-ho;Kim, Sang-hyun;Lee, Young-jin;Lim, Jong-chun;Han, Dong-kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.579-587
    • /
    • 2017
  • Although interventional procedures use very low tube currents, there is a high risk of exposure to radiation as well as the operator due to long-term radiation exposure. The purpose of this study is to investigate the effects of radiation dose on the quality of the operator by measuring the dose received by the operator in the interventional procedure of the cerebral vascular system and finding the shielding material and shielding method which can effectively shield the exposure from the medical radiation. And to find a way to minimize it to the extent that it does not. As a result, when the newly designed shielding system with Nano Tungsten material was used, it was confirmed that the mean dose was reduced by 7.95% on average by the operator. Also, the PSNR results were measured to be 38.44 dB when using the designed shielding material, and it was confirmed that Nano Tungsten does not affect the image quality. In conclusion, the Nano Tungsten shielding material proved to be capable of significantly reducing the operator radiation dose, without affecting the image quality. The use of the above materials is expected to solve the problems related to the harmfulness and economical efficiency of the human body and the environment, which have recently become an issue of shielding materials.

Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention (뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구)

  • Kim, Jongdeok;Ahn, ByeoungJu;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The bi-plane cerebrovascular angiography radiation is done the radiation exposure at the forward and lateral direction as opposed to the one of the source. So, the exposure dose of radiation workers increases further. Therefore, the medical diagnostic radiation workers as well as patients is interested to ways to reduce the dose. The exposure dose of cerebral angiography and interventional radiology must be considered the primary radiation of X-ray tube directly, scattered primary radiation between lateral tube and lateral detector and relatively small secondary scatter radiation in the walls of room. The aim of study is that the exposure dose of primary and scatter radiation reduce as much as possible to install protection device of lateral protection than common shielding of table and ceiling. As a result, the dose of fluoroscopy was reduced approximately 3.64 times the gonads, thyroid approximately 3.13 times, 4.42 times around eyes. And the dose of DSA was reduced approximately 4.98 times the gonads, thyroid approximately 3.00 times, 1.67 times around eyes. Consequently, medical practitioners can be helpful for radiation dose-exposure for the lateral protection of bi-plane cerebrovascular angiography more than the common shield method in cerebrovascular angiography and interventional radiological procedures.