Browse > Article
http://dx.doi.org/10.7742/jksr.2012.6.1.011

Reference levels for patient Radiation Dose in interventional radiological procedures  

Park, Hyeok (Department of Diagnostic Radiology, Chonnam National University Hospital)
Kim, Yong-Wan (Department of Diagnostic Radiology, Chonnam National University Hospital)
Jeon, Ju-Seob (Department of Diagnostic Radiology, Chonnam National University Hospital)
Publication Information
Journal of the Korean Society of Radiology / v.6, no.1, 2012 , pp. 11-17 More about this Journal
Abstract
The purpose of this study is to measure and evaluate radiation dose on patients in interventional radiological(IVR) procedures classified by each procedure, and aid as data for safety management. Fluroscopy time(F-time), dose area product(DAP) and number of acquired images from each kind of procedure was checked. Non-vascular procedures showed low value, and vascular procedure showed high value in all procedures except in IVC filter. F-time was longest in EVAR, which showed also the highest DAP value of all procedures. DAP-rate showed high value in TACE. By this result, we attempt to establish standard guideline of radiation dose on patients in IVR procedure.
Keywords
fluoroscopy time; DAP; DAP-rate;
Citations & Related Records
연도 인용수 순위
  • Reference
1 E Vano, R Sanchez, JM Fernandez, JJ Gallego, JF Verdu, M Gonzalez, A Azpiazu, A Segarra, MT Hernandez, M Canis, F Diaz, F Moreno, J Palmero, "Patient Dose Reference Levels for Interventional Radiology:A National Approach, Cardiovasc Intervent Radiol Vol. 32, pp.19-24, 2009.   DOI   ScienceOn
2 A KAWABE, Y TAKEDA, Y NAKAGIRI, " Reduction in Patient skin dose during interventional radiology with the use of an air gap substitute", The British Journal of Radiology, 2008.
3 한양대학교 방사선안전신기술연구센터, "중재적 의료절차에서 방사선 상해의 예방", 국제방사선방호위원회 간행물 85, http://www.icrp.org/docs/P085_Korean.pdf
4 Wagner, L.K., Archer, B.R., "Minimising Risks from Fluoroscopic X Rays. A Credentialing Program. 2nd Edition. R.M. Partnership, 3 EWedgemere Circle, The Woodlands, TX, USA, 1998.
5 Wagner, L.K., Archer, B.R., "Management of patient skin dose in fluoroscopically guided interventional procedures. J. Vasc. Intervent. Radiol. Vol. 11, pp.25-34, 2000.   DOI   ScienceOn
6 BJ McParland, "A study of patient radiation doses in interventional radiological procedures The British Journal of Radiology", Vol. 71, pp. 175-185, 1998.   DOI
7 D Bor, T Sancak, T Olgar, Y Elcim,, A Adanali, U Sanldilek, S Akyar, "Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology", British Journal of Radiology Vol. 77, pp.315-322, 2004.   DOI   ScienceOn
8 Ruiz Cruces R, GarcIa-Granados J, Diaz Romero FJ, Hernandez Armas J. Estimation of effective dose in some digital angiographic and interventional procedures. Br J Radiol, Vol. 71, pp.42-47, 1998.   DOI
9 Vano E, Sanchez R, Fernandez JM, et al. Patient dose reference levels for interventional radiology : a national approach. Cardiovasc Intervent Radiol, Vol. 32, pp.19-4, 2009.   DOI   ScienceOn
10 Verdun FR, Aroua A, Trueb PR, Vock P,Valley JF. Diagnostic and interventional radiology: a strategy to introduce reference dose level taking into account the national practice. Radiat Prot Dosimetry, Vol. 114, pp.188-91, 2005.   DOI   ScienceOn
11 Vano E, Jarvinen H, Kosunen A, et al. Patient dose in interventional radiology: a European survey. Radiat Prot Dosimetry, Vol. 129, pp.39-5, 2008.   DOI   ScienceOn
12 Miller DL, Kwon D, Bonavia GH. Reference levels for patient radiation doses in intercentional radiology; proposed initial values for U.S. practice, Vol. 253, No. 3, pp. 753-764, 2009.   DOI   ScienceOn
13 UNSCEAR, "Effect and Risk of Ionizing Radiation", UNSCEAR Repf, 1998.
14 Bushong, S. C., "Radiologic Science for Technologists: Physics, Biology, and Protection (6th ed.), 1993.
15 도영수, 김현범, 박흥석, 정환훈, 김창원, 강병철, 박광보, 홍광표, 강병삼, 고인범, 한영이, 하명진, "혈관조영X-선장치의 안전관리 기준 개발, 식품의약품안전청 용역연구개발사업, 2003.
16 식품의약품안전청, " 환자선량 측정 가이드라인", 방사선안전관리시리즈 No.14, 2007.
17 김혁주,이정은,이현구,김병우, 정진백, 양현규,임천일, 차선희, 손혜경, 김지혜, "의료 방사선 안전 가이드라인 마련을 위한 연구", 식품의약품안전청 용역연구개발사업, 2010
18 이광용, "진단방사선분야에서의 환자선량 평가 및 환자 방어", 대한인터벤션영상기술학회, pp.16-21, 2003.
19 정진욱, "중재적방사선분야에서의 환자피폭선량 평가", 식품의약품안전청연구보고서 제 11권, 2007.
20 Bryk SG , Censullo ML , Wagner LK , Rossman LL , Cohen AM . Endovascular and interventional procedures in obese patients:a review of procedural technique modifi cations and radiation management . J Vasc Interv Radiol Vol. 17, No. 1, pp.27-33, 2006.   DOI   ScienceOn
21 Gray, Archer Br, and P.F.Butler, "Reference values for diagnostic radiology : application and impact," Radiology, Vol.235, pp.354-358, 2005.   DOI   ScienceOn
22 http://sizekorea.kats.go.kr