• Title/Summary/Keyword: 중재시술

Search Result 156, Processing Time 0.036 seconds

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Reference Levels for Radiation Dose in Angiography and Interventional Radiology : In the Cerebrum (혈관 조영 검사 및 중재적 방사선 시술시 방사선량에 대한 참고 기준치 : 대뇌 중심으로)

  • Han, Jae-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.302-308
    • /
    • 2011
  • The aim of this study is to compare reference levels for radiation dose in angiography and interventional radiology. Proposed reference levels for various procedures and classification of diseases are provided by fluoroscopy time and kerma area product(KAP) rate normalizing the body habitus focusing the cerebrum. Subarachnoid hemorrhage(SAH) represents the highest KAP-rates and aneurysm represents the lowest KAP-rates. According to these types of procedures, internal carotid artery(ICA), common carotid artery(CCA), and vertebral artery(VA) show the highest KAP-rates and guglielmi detachable coil shows the lowest KAP-rates. Therefore, the present study can suggested reference levels for patient radiation dose and is expected to be further useful in the field of radiation dose education and management of angiography and interventional radiology.

Recent Interventional Procedures for Spinal Discogenic Pain for Life Care : Technical and Ethical Issues (라이프케어를 위한 추간판성 통증 치료의 최신중재기법 기술적 윤리적 문제들에 관하여)

  • Hong, Young-Ki
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.4
    • /
    • pp.311-320
    • /
    • 2019
  • Discogenic pain which develops during the degenerative process of intervertebral disc is an intractable disease of musculoskeletal system. Unlike other diseases in modern medical science, it is not clinically confirmed through objective imaging and clinicopathologic index. Moreover, current technology has been facing difficulties finding fundamental treatment. This study examined through reviewing literature whether the therapeutic rationales of interventional procedures for the discogenic pain, such as nerve block, intradiscal electrothermal therapy and nucleoplasty, are valid and whether safety reviews such as preclinical tests are carried out faithfully during the technology development process. As a result, it is presumed that there is not yet an interventional treatment for discogenic pain, whose therapeutic rationale has been objectively verified. And there are some cases of interventional treatment that have not been adequately equipped with the preclinical test steps necessary to review the safety of the procedure during the technology development process. In conclusion, since there is still no interventional treatment for discogenic pain which has clear therapeutic rationale, it is necessary to recognize that a more careful approach is needed to judge whether the procedure is performed in clinical settings. And medical ethical issues may arise for some interventional treatment that are deemed to have been carried out without a thorough review of safety.

The Characteristic of Radiation Exposure for Radiologist with Applying Condition in Interventional Radiology in Cardiology (심장내과의 중재적 시술시 시술조건에 따른 방사선사의 방사선 노출 특성)

  • Park, Jeong-Kyu;Cho, Euy-Hyun
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.421-429
    • /
    • 2012
  • Lately, the number of interventional radiology is increased by the extension of procedure in medical radiation, and radiation exposure may be appeared differently by interventional radiologists, it is caused increase of radiation dose for radiation worker, patient, and radiologists. This study has done a comparative analysis characteristic of radiation exposure for five radiologists who executed interventional cardiology for 303 patients in S university hospital of Gyeong-Buk from Nov. 1, 2011 to Jan. 31, 2011. The average exposure time of five radiologists was 697.95sec. The average of cumulative DAP(exp) for patients was $52,730mGycm^2$ and the average of total DAP for patients was $104,875.14mGycm^2$. The average of frames for image was 855.52 frames in acquired images, and the average of frames for images was 802.2 frames in exposure images. They were statistically significant differences (p<0.05). Exposure time, cumulative DAP(fluro), cumulative DAP(exp), total DAP, acquired image, and exposure image were high correlation except cumulative DAP(exp), and acquired runs in x-ray exposure characteristics of machine. Exposure time was a great influence on radiologist. It signified that the more exposure time lead to the more radiation dose for radiologist. Radiation dose is related to ability, experience, difficulty, and precision of procedures in interventional procedure. The number of angiography and exposure time is difficult to control by radiologists. Therefore, it is in need of reasonable system which was evaluated the real dose of medical teams in interventional proceedings. We think that self education and training are required to reduce radiation dose for radiologists and radiation workers.

CT Imaging for Mitral Valve Surgery and Intervention (승모판막수술 및 중재술을 위한 전산화단층영상)

  • Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.290-301
    • /
    • 2020
  • The surgical technique of mitral valvuloplasty or transcatheter mitral valve (MV) replacement has been developed recently. Surgeons and interventionists require detailed anatomical information on the MV for the purpose of treatment planning. In this review, we discussed the anatomic features of the MV on CT and the method of evaluating the MV for treatment planning, as well as its preservation, for interventional procedures.

Ultrasound-Guided Intervention for Breast Lesions (유방 병변에 대한 초음파 유도하 중재 시술)

  • Eun Young Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.332-344
    • /
    • 2023
  • The role of ultrasound-guided interventions in the diagnosis and treatment of breast lesions is gaining importance and prevalence, particularly as the instances of non-palpable breast lesion detection, breast-conserving surgery, and neoadjuvant chemotherapy are increasing. This review attempts to summarize the types and techniques of breast ultrasound-guided interventional procedures, such as biopsy, tissue marker insertion, and preoperative localization, and their indications. Furthermore, we highlight the pro and cons of the most commonly used procedures with the intention of promoting their use in clinical practice.

The Evaluation of Patients' Radiation Dose During TACE of Interventional Radiology (TACE의 중재적 시술시 환자의 피폭선량 평가)

  • Lee, Seung-Youl;Lim, Hyun-Soo;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.209-214
    • /
    • 2011
  • Goal of this study was to measure effective radiation dose of highly exposed patients who were treated by TACE, interventional radiology from June to September 2010. The effective radiation dose was approximately measured by weighted DAP (dose area product) with the ionization chamber which is inserted in angiography equiment (Philips Allura Xper FD 20). Radiation dose was measured by TLD which was attached to patients' thyroid and genital gland. The average of ED (effective dose) was 18.43${\pm}$6.63 mSv per person and the average of radiation dose of thyroid and genital gland was 0.37 mSv, 0.77 mSv, respectively. The mean radiation dose of operators who wear the protector was 0.07 mSv for thyroid, and 0.01 mSv for genital gland, respectively. All staffs involved in TACE treatment, have to keep them aware and use the appropriate protectors to reduce the radiation dose of patient.