• Title/Summary/Keyword: 중량측정법

Search Result 209, Processing Time 0.022 seconds

A Deep Learning Method for Cost-Effective Feed Weight Prediction of Automatic Feeder for Companion Animals (반려동물용 자동 사료급식기의 비용효율적 사료 중량 예측을 위한 딥러닝 방법)

  • Kim, Hoejung;Jeon, Yejin;Yi, Seunghyun;Kwon, Ohbyung
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.2
    • /
    • pp.263-278
    • /
    • 2022
  • With the recent advent of IoT technology, automatic pet feeders are being distributed so that owners can feed their companion animals while they are out. However, due to behaviors of pets, the method of measuring weight, which is important in automatic feeding, can be easily damaged and broken when using the scale. The 3D camera method has disadvantages due to its cost, and the 2D camera method has relatively poor accuracy when compared to 3D camera method. Hence, the purpose of this study is to propose a deep learning approach that can accurately estimate weight while simply using a 2D camera. For this, various convolutional neural networks were used, and among them, the ResNet101-based model showed the best performance: an average absolute error of 3.06 grams and an average absolute ratio error of 3.40%, which could be used commercially in terms of technical and financial viability. The result of this study can be useful for the practitioners to predict the weight of a standardized object such as feed only through an easy 2D image.

A Study on the Development and the Uncertainty Analysis of Oil Flow Standard System (기름 유량표준장치의 개발 및 측정 불확도에 관한 연구)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1071-1080
    • /
    • 2003
  • A national standard system was developed in order to calibrate and test the oil flowmeters for the petroleum field. A stop valve and a gyroscopic weighing scale were employed for the primary standard of the flow quantity. It is operated by the standing start and finish mode and the static weighing method. The model equation for uncertainty evaluation was based on the calibration principle of standard system. The sources of the uncertainties were quantified and combined according to the GUM(Guide to the Expression of Uncertainty in Measurement). It was found that the standard system had the relative expanded uncertainty of 0.04 % in the range of 18 - 350 ㎥/h. According to the uncertainty budget, the uncertainties of the fluid density and the volume of pipeline, which were temperature dependent, contributed 92% of final uncertainty in the oil flow standard system.

Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique (Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

CMC Evaluation of Flowmeter Calibration System for Liquid (액체용 유량계교정시스템의 교정측정능력 평가)

  • Lee, Dong-Keun;Kim, Jong-Seob;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.4
    • /
    • pp.5-10
    • /
    • 2014
  • It is possible for the nation's largest flowmeter calibration system in K-water to calibrate flow rate up to $2,700m^3/h$ and diameter 800mm. However, the calibration and measurement capability of K-water's system is not satisfied in comparison with other developed countries. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the combined standard uncertainty has been improved $1.099{\times}10^{-3}$ to $2.332{\times}10^{-4}$. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).

A Study on Life Time Prediction of ACM Rubber Composite Using Accelerated Test and Thermogravimetric Analysis (노화촉진시험법 및 TGA를 이용한 ACM 고무복합재료의 수명 예측 연구)

  • Ahn, WonSool;Lee, Joon-Man;Lee, Hyung Seok
    • Elastomers and Composites
    • /
    • v.49 no.2
    • /
    • pp.144-148
    • /
    • 2014
  • Compression set (CS) and weight loss by thermal degradation of the ACM rubber composite sample prepared for an automotive part were measured simultaneously at several given temperatures of $150^{\circ}C$, $160^{\circ}C$, $170^{\circ}C$, and $180^{\circ}C$. Using the relationship between them, thermal life of the sample could be predicted at a given operating temperature by applying Toops method which is based on the analysis of non-isothermal TGA thermograms. Conversion by weight loss showed a linear relationship with CS changes, exhibiting 4.2% at CS 40%. Activation energy of thermal degradation was calculated as 120.2 kJ/mol at 4.2% of weight loss from Flynn-Wall-Ozawa analysis. When the expected life was set as time to reach CS 40% at $120^{\circ}C$, the life time of the sample was calculated as 9,700 hrs when Toops method was applied.

A study on the vibration characteristics of carbon/epoxy propeller shaft (카본/에폭시 복합재로 제작된 수송기계용 추진축의 진동특성에 관한 연구)

  • 여운기;김희송;공창덕;정종철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.31-39
    • /
    • 2001
  • Composite propeller shafts for a vehicle have major advantages such as reduction of vibration, noise, and weight. A propeller shaft was designed with a carbon/epoxy composite material using the finite element method(FEM), and prototype shafts for tests were manufactured by the filament winding manufacturing process. In order to verify the design procedure by FEM, Two kinds of experimental tests were carried out using a FFT analyzer with impact hammers and a critical speed measuring apparatus for measurement of natural frequencies and critical speeds. The difference between the FEM analysis result and the test result was less than 3.4%, showing FEM analysis results to be acceptable. The parametric study was focused on determining the factor affecting the vibration and strength characteristics of the propeller shaft based on FEM. In investigation of the change in natural frequency without an increase in propeller shaft weight, it was found that the winding angle is the most significant factor affecting the vibration and strength characteristics.

  • PDF

Analysis of Sand Water Ratio and Drying Unit Weight Using Flat TDR System (Flat TDR 시스템을 이용한 모래의 함수비와 건조단위중량 분석)

  • Lee, Junesung;Kim, Daehyeon
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.333-342
    • /
    • 2021
  • In this study was conducted to measure the water content and dry unit weight of the ground using TDR (Time Domain Reflectometry) in order to supplement the problems of the conventional compaction management method. The Flat TDR system is a device that does not cause ground disturbance, and in order to verify the measured values, the dry density and water content were measured for samples of the ground subject at 7 sites other than Jumunjin Standard Temple. The water content section was divided into 6 sections of 3, 6, 9, 12, 15, and 18%, and the experimental results were confirmed according to the unified classification method. As a result of the indoor experiment, the water content showed an error of about 0.7% for the SP sample and about 1.3% for the SM sample. In addition, the dry unit weight confirmed an error of about 7% for the SP sample and about 5% for the SM sample. It was confirmed that stable values were derived in sandy or silty sandy ground except for clay or gravel. Through the experimental results, it was confirmed that the measured values of the flat TDR system derive similar values to the existing traditional compaction management method, and it was determined that the flat TDR equipment was suitable for construction sites that require quick constructability and economic feasibility.

Preparation and Swelling Properties of Poly(potassium acrylate-co-acrylamide) Superabsorbent Particles (폴리(아크릴산 포타슘-co-아크릴아마이드) 고흡수성 입자의 제조 및 팽윤 특성)

  • 손오건;심상준;이동현;이영관;김지홍;김덕준
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • Superabsorbent poly(potassium acrylate-co-acrylamide)s were synthesized in particle form using inverse suspension polymerization technique. Mean diameter of the prepared polymer particles decreased from 300 to 50 $\mu\textrm{m}$ with increasing surfactant concentration. The dynamic and equilibrium swelling behaviors during water absorption and drying process were investigated by weight measurement. The swelling ratio of polymer particles in water changed according to not only polymer crosslinking density, but particle size, saline concentration of aqueous medium, and copolymer compositions. Water sorption amount was increased with decreasing particle size, crosslinking agent concentration, and ion concentration in bulk solution. Being different from the water sorption process, the drying process was not significantly affected by particle size, polymer composition, or crosslinking amount.

그라핀이 코팅된 저탄소강의 고분자전해질 연료전지 양극판으로서의 적용

  • Nam, Dae-Geun;Kim, Jeong-Su;Park, Yeong-Do;O, Won-Tae;Jo, Hyeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.44.2-44.2
    • /
    • 2011
  • 고분자 전해질 연료전지는 다른 연료전지에 비해 작동온도가 낮고 전류밀도 및 출력밀도가 높으며 시동시간이 짧아서 다양한 분야에 응용이 가능할 것으로 기대된다. 그 중 양극판은 가격비와 중량비가 높아 부품 가격 및 중량을 낮출 경우 파급 효과가 높은 것으로 예상된다. 본 연구에서는 일반적으로 사용하고 있는 스테인리스강보다 가격이 저렴한 저탄소강을 모재로 이용하였다. 저탄소강은 자체로 내식성을 가지지 못하므로, 최근에 차세대 신소재로 각광을 받고 있는 그라핀(graphene)을 전기분무(electro spray coating)법으로 코팅하여 저탄소강의 내식성을 향상시키고자 하였다. 그라핀은 에탄올을 용매로 사용하여 분산하였으며, 분산제로 소량의 다이페닐다이에톡시실란(diphenyldiethoxysilane)을 첨가하여 코팅용액을 제작하였다. 코팅공정은 5~15 kV의 전압을 가하여 1시간동안 코팅을 진행하였으며, 그라핀-저탄소강의 미세구조를 주사전자현미경과 광학현미경을 통하여 관찰하였다. 또한 X-선 회절분석법을 이용하여 그라핀의 결정구조를 분석하였다. 한편 스택의 내부와 유사한 산화성 분위기를 모사하기 위해 $80^{\circ}C$의 0.1N $H_2SO_4$+2ppm $F^-$ 용액에서 내식성 실험을 수행하였고 면간접촉저항을 측정하였다. 그라핀이 코팅된 저탄소강 시편은 고분자 전해질 연료전지 양극판의 요구조건을 만족하였으며, 연료전지 양극판으로서의 사용가능성을 확인하였다.

  • PDF

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.