Browse > Article
http://dx.doi.org/10.5293/kfma.2014.17.4.005

CMC Evaluation of Flowmeter Calibration System for Liquid  

Lee, Dong-Keun (K-water Institite)
Kim, Jong-Seob (K-water Institite)
Park, Tae-Jin (K-water Institite)
Park, Jong-Ho (Chungnam National University)
Publication Information
Abstract
It is possible for the nation's largest flowmeter calibration system in K-water to calibrate flow rate up to $2,700m^3/h$ and diameter 800mm. However, the calibration and measurement capability of K-water's system is not satisfied in comparison with other developed countries. In this study, we find the dominant factors related to the uncertainty of weight and time measurement for gravimetric flowmeter calibration system. As a results of improving the system, the combined standard uncertainty has been improved $1.099{\times}10^{-3}$ to $2.332{\times}10^{-4}$. So calibration and measurement capability got 0.08 percent of the relative expanded uncertainty for maximum flow rate using the coverage factor(k=2).
Keywords
Flowmeter; Calibration and measurement capability; Uncertainty; Gravimetric method; Flow conditioner; Diverter; Load cell;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 정낙삼, 최종오, 1999, "측정에서의 불확도 표현에 대한 지침," Report of KRISS, KRISS-99-070-SP.
2 이동근, 김종섭, 이행수, 심동혁, 추성훈, 2012, "유량계 교정시스템 교정측정능력 향상 연구," KIWE-FE-12-06, 한국수자원공사.
3 이동근, 조용, 2012, "유동교란인자(축소.확대관, Tee관) 상하류에 설치된 다회선초음파유량계의 특성," 대한기계학회 논문집 B권, 제36권, 제8호, pp. 877-883.
4 이동근, 박주영, 이행수, 2008, "국가표준수준의 유량계 교정시스템 개발 연구," KIWE-WFERC-08-03, 한국수자원공사.
5 이동근, 박종호, 2008, "액체용 유량계 교정시스템의 Diverter 불확도 특성연구," 유체기계저널, 제11권, 제3호, pp. 50-55.
6 ISO 5167-1, 2003, "Measurement of Fluid Flow by means of Pressure Differential Devices Inserted in Circular Cross-section Conduits Running Full - Part 1 : General Principles and Requirements."
7 ISO 4185, 1980, "Measurement of Liquid Flow in Closed Conduits - Weighing Methods."
8 이광복, 2002, "물 유량 표준시스템 불확도 평가," 유체기계저널, 제5권, 제4호, pp. 93-102.   과학기술학회마을   DOI