• Title/Summary/Keyword: 주파수 변환기

Search Result 921, Processing Time 0.027 seconds

Evaluation of Image Quality for Scattered X-rays using in Digital Radiography (디지털방사선영상에서 산란선의 영상특성 평가)

  • Kim, Hansol;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.395-403
    • /
    • 2022
  • Flat-panel detector (FPD) used in digital radiographic imaging systems was used to perform a quantitative power spectrum evaluation as a result of the thickness change of polymethyl methacrylate (PMMA), a tissue equivalent. As the PMMA thickness increases with the resolution-chart phantom image, the effect of the scattering line increases, indicating that the modulation characteristics decrease, and the image is bright. The results show that the noise of the image increases, and noise-power spectral images are obtained by Fourier transform to confirm by spatial frequency. Thus, it can be verified that the PMMA thickness and noise are proportional through the result of evaluating the change of resolution characteristics and representing the 2D noise-power spectrum as one-dimensional values by evaluating the change of scattering line with MTF as the PMMA thickness increases in the image.

A Study on Reconstruction Performance of Phase-only Holograms with Varying Propagation Distance (전파 거리에 따른 위상 홀로그램 복원성능 분석 및 BL-ASM 개선 방안 연구)

  • Jun Yeong Cha;Hyun Min Ban;Seung Mi Choi;Jin Woong Kim;Hui Yong Kim
    • Journal of Broadcast Engineering
    • /
    • v.28 no.1
    • /
    • pp.3-20
    • /
    • 2023
  • A computer-generated hologram (CGH) is a digitally calculated and recorded hologram in which the amplitude and phase information of an image is transmitted in free space. The CGH is in the form of a complex hologram, but it is converted into a phase-only hologram to display through a phase-only spatial light modulator (SLM). In this paper, in the process of including the amplitude information of an object in the phase information, when a technique that includes subsampling such as DPAC is used, we showed experimentally that the bandwidth of the phase-only hologram increases, and as a result, aliasing that was not present in the complex hologram can occur. In addition, it was experimentally shown that it is possible to generate a high-quality phase-only hologram by restricting the spatial frequency range even at a distance where the numerical reconstruction performance is degraded by aliasing.

Unsupervised Vortex-induced Vibration Detection Using Data Synthesis (합성데이터를 이용한 비지도학습 기반 실시간 와류진동 탐지모델)

  • Sunho Lee;Sunjoong Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.5
    • /
    • pp.315-321
    • /
    • 2023
  • Long-span bridges are flexible structures with low natural frequencies and damping ratios, making them susceptible to vibrational serviceability problems. However, the current design guideline of South Korea assumes a uniform threshold of wind speed or vibrational amplitude to assess the occurrence of harmful vibrations, potentially overlooking the complex vibrational patterns observed in long-span bridges. In this study, we propose a pointwise vortex-induced vibration (VIV) detection method using a deep-learning-based signalsegmentation model. Departing from conventional supervised methods of data acquisition and manual labeling, we synthesize training data by generating sinusoidal waves with an envelope to accurately represent VIV. A Fourier synchrosqueezed transform is leveraged to extract time-frequency features, which serve as input data for training a bidirectional long short-term memory model. The effectiveness of the model trained on synthetic VIV data is demonstrated through a comparison with its counterpart trained on manually labeled real datasets from an actual cable-supported bridge.

A Study on THz Generation and Detection Characteristics of InGaAs Semiconductor Epilayers (InGaAs 반도체 박막의 테라헤르쯔(THz) 발생 및 검출 특성 연구)

  • Park, D.W.;Kim, J.S.;Noh, S.K.;Ji, Young-Bin;Jeon, T.I.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.264-272
    • /
    • 2012
  • In this paper, we report THz generation and detection characteristics investigated by InGaAs semiconductor epilayers, as results of a basic study obtained from the InGaAs-based THz transmitter/receiver (Tx/Rx). High-temperature and low-temperature (LT) grown InGaAs epilayers were prepared by the molecular beam epitaxy technique for the characterization of THz generation and detection, respectively, and the surface emission based on the photo-Dember effect was tried for THz generation. THz wave was generated by irradiation of a Ti:Sapphire fs pulse laser (60 ps/83 MHz), and a LT-GaAs Rx was used for the THz detection. The frequency band shown in the spectral amplitudes Fourier-transformed from the measured current signals was ranging in 0.5~2 THz, and the signal currents were exponentially increased with the Tx beam power. The THz detection characteristics of LT-InGaAs were investigated by using an Rx with dipole (5/20 ${\mu}m$) antenna, and the cutoff frequency was ~2 THz.

Dewatering of Soybean Milk Residue by Hydraulic Press with Ohmic Heating (Ohmic Heating을 이용한 두유박의 압착탈수)

  • Cho, Won-Il;Pyun, Yu-Ryang;Lee, Youn-Soo;Kwon, Ik-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.324-329
    • /
    • 1996
  • In order to develop a novel dewatering process for soybean milk residue, hydraulic press with ohmic heating was built and its expression conditions were examined. The electric conductivity of raw soybean milk residue was 0.128 S/m and increased linearly with increasing temperature. Water content of the residue could be reduced to 74% with the conventional hydraulic press, but to less than 70% by applying ohmic heating to the hydraulic press. The most effective dewatering was achieved by applying alternative current with 5 kHz frequency at 60 V during expression. The solid content of the expressed liauid was markedly reduced from 10% to 3.3% by ohmic heating during expression. Temperature of the cake rose to above $95^{\circ}C$ during the dewatering due to ohmic heating.

  • PDF

Advanced LWIR Thermal Imaging System with a Large Zoom Optics (줌 광학계를 이용한 원적외선 열상장비의 설계 및 제작)

  • Hong, Seok-Min;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.354-360
    • /
    • 2005
  • A high performance LWIR(long wavelength infra red) zoom thermal imaging sensor using $480{\times}6$ HgCdTe(MCT) linear detector has been developed by ADD Korea. The optical system consists of zoom telescope having large objective about 190 mm diameter and optically well corrected scanning system. The zoom ratio of the telescope is 3: 1 and its magnification change is performed by moving two lens groups. And also these moving groups are used for athermalization of the system. It is certain that the zoom sensor can be used in wide operating temperature range without any degradation of the system performance. Especially, the sensor image can be displayed with the HDTV(high definition television) format of which aspect ratio is 16:9. In case of HDTV format, the scanning system is able to display 620,000 pixels. This function can make wider horizontal field of view without any loss of performance than the normal TV format image. The MRTD(minimum resolvable temperature difference) of the LWIR thermal imaging sensor shows good results below 0.04 K at spatial frequency 2 cycles/mrad and 0.23 K at spatial frequency 8 cycles/mrad at the narrow field of view.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Implementation of Readout IC for $8\times8$ UV-FPA Detector ($8\times8$ UV-PPA 검출기용 Readout IC의 설계 및 제작)

  • Kim, Tae-Min;Shin, Gun-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.503-510
    • /
    • 2006
  • Readout circuit is to convert signal occurred in a defector into suitable signal for image signal processing. In general, it has to possess functions of impedance matching with perception element, amplification, noise reduction and cell selection. It also should satisfies conditions of low-power, low-noise, linearity, uniformity, dynamic range, excellent frequency-response characteristic, and so on. The technical issues in developing image processing equipment for focal plane way (FPA) can be categorized as follow: First, ultraviolet (UV) my detector material and fine processing technology. Second, ReadOut IC (ROIC) design technology to process electric signal from detector. Last, package technology for hybrid bonding between detector and ROIC. ROIC enables intelligence and multi-function of image equipment. It is a core component for high value added commercialization ultimately. Especially, in development of high-resolution image equipment ROIC, it is necessary that high-integrated and low-power circuit design technology satisfied with design specifications such as detector characteristic, signal dynamic range, readout rate, noise characteristic, ceil pitch, power consumption and so on. In this paper, we implemented a $8\times8$ FPA prototype ROIC for reduction of period and cost. We tested unit block and overall functions of designed $8\times8$ FPA ROIC. Also, we manufactured ROIC control and image boards, and then were able to verify operation of ROIC by confirming detected image from PC's monitor through UART(Universal Asynchronous Receiver Transmitter) communication.

Enhanced Energy Harvester Based on Vibration Analysis of Bicycle Riding (자전거 주행의 진동 분석에 기반한 에너지 수확 증진 기술 개발)

  • Yeo, Jung-Jin;Ryu, Mun-Ho;Kim, Jung-Ja;Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • Bicycle has a large amount of kinetic energy available for energy harvesting technology in its speedy and balanced riding movement. Systematic and realistic analysis of its dynamic property is essential to improve the efficiency of energy harvester. However, there has not been enough researches about precise measurement or analysis of bicycle dynamics on real roads. This study aims to investigate the characteristics of vibrational movement of bicycle using MEMS-based accelerometer and to develop a prototype of electromagnetic energy harvester with nonlinear behavior which is proper to the random vibrations accompanied in bicycle riding. The vibrational components have average magnitude of 1 g and turn out to be independent of riding speed. The developed prototype of energy harvester was installed on a front port of a bicycle to use this ambient vibration and generated an average electrical power of 1.5 mW which is enough to support power for most of portable sensors and short range radio-frequency communication. Further study about isolation of vibration from a rider and conversion efficiency is ongoing. The developed energy harvester is expected to be a platform technology for sustainable portable power supply for various smart IT devices and applications.

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF