• Title/Summary/Keyword: 주요 원소

Search Result 1,151, Processing Time 0.027 seconds

Principle and Applications of EELS Spectroscopy in Material Characterizations (재료 분석에서 전자 에너지 손실 스펙트럼 (EELS)의 원리 및 응용 연구)

  • Yoon, Sang-Won;Kim, Kyou-Hyun;Ahn, Jae-Pyoung;Park, Jong-Ku
    • Journal of Powder Materials
    • /
    • v.14 no.3 s.62
    • /
    • pp.157-164
    • /
    • 2007
  • An electron energy loss spectroscopy (EELS) instrument attached on transmission electron microscopy (TEM) becomes a powerful and analytical tool for extracting the noble information of materials using the enhancement of TEM images, elemental analysis, elemental or chemical mapping images, electron energy loss near edge structure (ELNES), and extended energy-loss fine structure (EXELFS). In this review, the principle and applications of EELS which is widely used in material, life, and electronic sciences were introduced.

G009의 이화학적 특성

  • Park, Man-Ki;Park, Jung-Il;Lee, Mi-Young;Kim, Soo-Woong;Lee, Seung-Ryong;Jung, Hoon;Lee, Jun-Ho;Han, Man-Duk
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.204-204
    • /
    • 1994
  • Ganoderma lucidum의 균사체로 부터 얻어진 G009의 이화학적 특성을 규명하였다. G009는 넓은 범위의 분자량 분포를 가지고 있는 다당체로 분자량 9.4kD의 물질이 주성분이었다 G009의 당의 함량은 약 70%이었고 단백질은 약 2.4%인 것으로 나타났다. G009의 주요 구성당은 glucose, xylose, mannose, galactose 등이었고, glycine, leucine, alanine, valine, isoleucine, proline 등 17종의 아미노산이 확인되었다. 유기원소 분석 결과 G009는 탄소 약 40%, 수소 5.7%, 질소 1.8%의 구성비를 보였으며, 무기원소 분석결과 Ca, Mg, Zn 등이 확인되었다. 이상의 결과로 부터 G009는 9.4 kD의 분자량을 갖는 단백다당체를 주성분으로 하는 당화합물로 추정된다.

  • PDF

광미-산용액 용출실험에서 용해된 중금속의 화학적 존재형태 연구

  • Gang Min-Ju;Lee Pyeong-Gu;Choi Byeong-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.213-215
    • /
    • 2006
  • 반응용액의 pH와 반응시간에 따른 용출실험 결과를 PHREEQC를 이용하여 용출된 중금속이 어떠한 화학적 형태가 우세한지 알아보고자 하였다. 용출용액에 용해된 Zn, Cd, Cu, Mn 및 Fe의 주요 존재형태는 free ion 및 sulfate complexes($metal-SO_4$)인 것으로 계산되었다. pH 5와 pH 3의 조건에서 각 원소의 화학적 존재형태는 서로 유사하고, 반응시간이 증가할수록 free ion 상태로 존재하는 비율은 감소하고 sulfate complexes로 존재하는 비율은 증가하는 경향을 보였다. pH 1에서 용출된 용액에 존재하는 각 원소의 화학적 존재형태는 sulfate의 농도가 크게 증가됨에도 불구하고 free ion 상태로 존재하는 금속이온의 함량의 증가비율보다 sulfate complexes로 존재하는 함량의 증가비율이 더 큰 것으로 예측되었다.

  • PDF

Development of stainless steel for automotive exhaust systems (자동차 배기관용 스테인리스 강재 개발)

  • 이용득;박수호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.39-47
    • /
    • 1991
  • 본 연구논문의 내용은 현재 국내 자동차 업계에서 자동차 배기부품으로 전량 수입되고 있는 STS 409L 스테인레스강을 국산화하기 위한 개발연구에 대한 내용으로서 배기관용 스테인레스강 409L의 제조기술과 관련된 국내외 기술개발 동향과 포항제철 스테인레스 제조설비에 맞는 적정합금성분계와 조업조건을 도출하기 위하여 실험적으로 시험조사하여 품질 제특성을 평가한 연구결과이다. 주요 내용으로서 합금원소가 열연 및 냉연 소둔조업조건에 미치는 영향을 조사하기 위하여, C, N과 Ti 또는 Ti+Nb 원소 첨가를 변화시킨 409L 계열강에 있어서 소둔조업조건에 따른 재결정과 상변태 거동을 조사하엿으며, TIG용접에 의한 용접부의 기계적 특성과 가공성 그리고 고온부식 및 응축수 부식 시험을 통한 내식성 등의 품질 특성 평가를 조사 서술하였다.

  • PDF

Adsorption Properties of Heavy Metal Elements using Zeolite (제올라이트를 이용한 중금속 원소들의 흡착 특성)

  • Shim, Sang-Kwon;Park, Jin-Tai;Kim, Tae-Sam
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.96-100
    • /
    • 2000
  • The adsorption of heavy-elements to zeolite has been investigated at various adsorptional condition for purification of waste water. Four heavy elements, Cd, Cr, Cu and Pb, were examined, because they are concerned to the major heavy-element contamination. The adsorption efficiencies are measured at the different conditions such as adsorption times and pHs. The practical adsorption was achived and reaches to maximum within 30 minute by using of 2-g zeolite for 50 mL of heavy-element solution. The overall adsorption efficiencies for Cr and Cu are high and become better at low pH. Cd and Pb have 95% of adsorption ratio and this is lower than other two elements. Cadmium shows an abnormally low adsorption at low pH.

  • PDF

Evaluation of Airborne Pb Sources in an Industrialized City by Applying Pb Isotope Ratios and Concentrations in PM10 (PM10 내 납의 동위원소와 농도를 활용한 산업도시지역 대기 중 납 오염원 평가)

  • Jo, Wan-Kuen;Lee, Heon-Chul;Kim, Mo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.174-182
    • /
    • 2011
  • The present study evaluated the major lead sources in a steel metallurgy industrialized city by measuring lead isotopes/lead concentrations of ambient air and potential sources in an industrial area and residential areas according to relative distance. The quality control program obtained during the measurement procedure for lead isotopes and concentrations exhibited $0.5ng/m^3$ for method detection limit, more than 90% for recoveries of standard particulate matters, and lower than 0.2% for reproducibility errors of four lead isotopes ($^{204}Pb$, $^{206}Pb$, $^{207}Pb$, $^{208}Pb$). For all three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$), the ratios were obtained in the industrial area were closer to nearby residential area than those of a residential area far away from the industrial area, thereby suggesting that lead sources were more similar each other in the industrial and nearby residential area. Furthermore, for both summer and winter seasons ambient lead concentrations were more than four times higher in the industrial area than in the residential areas and in turn, they were higher in the nearby residential area compared with the far-away residential area. As a result, it was suggested that lead emitted from the industrial area would influence more the ambient lead in the nearby residential area than the far-away residential area. Both slag and traffic emissions are likely to be major lead sources in the industrial and nearby residential areas, since their three lead isotope ratios ($^{206}Pb/^{204}Pb$, $^{207}Pb/^{206}Pb$, $^{208}Pb/^{206}Pb$) were similar to the ratios obtained from ambient air of these two areas. In addition, the lead isotope ratios revealed different pattern between seasons, and the ambient lead concentrations were higher for winter than for summer.

Oxidation of Elemental Mercury using Dielectric Barrier Discharge Process (유전체 장벽 방전을 이용한 원소수은의 산화특성)

  • Byun, Youngchul;Ko, Kyung Bo;Cho, Moo Hyun;NamKung, Won;Shin, Dong Nam;Koh, Dong Jun;Kim, Kyoung Tae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.2
    • /
    • pp.183-189
    • /
    • 2007
  • We have investigated the oxidation of gas phase elemental mercury using dielectric barrier discharge (DBD). In the DBD process, active species such as $O_3$, OH, O and $HO_2$ are generated by collisions between electrons and gas molecules. Search active species convert elemental mercury into mercury oxide which is deposited into the wall of DBD reactor because of its low vapor pressure. The oxidation efficiency of elemental mercury has been decreased from 60 to 30% by increasing the initial concentration of the elemental mercury from 72 to $655{\mu}g/Nm^3$. The gas retention time at the DBD reactor has showed the little effect on the oxidation efficiency. The more oxygen concentration has induced the more oxidation of elemental mercury, whereas there has been no appreciable oxidation within pure $N_2$ discharge. It has indicated that oxygen atom and ozone, generated in air condition determine the oxidation of elemental mercury.

Inferring Animal Husbandry Practice in the Baekje Period using Stable Isotope Analysis of Animal Bones from the Pungnaptoseong Fortress (풍납토성 출토 동물뼈의 탄소와 질소 안정동위원소 분석을 통해 본 백제시대의 가축사육 양상)

  • Choe, Hyeon Goo;Shin, Ji Young;Han, Ji Sun
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.179-188
    • /
    • 2016
  • This paper presents a new information on animal husbandry practice in the Baekje period using stable isotope analysis of 17 animal bones excavated from the Pungnaptoseong Fortress. Stable carbon isotope evidence implies that wild animals such as deer and pigs had mainly $C_3$-based diet whereas domestic cattle and horses might have consumed more $C_4$ plants. In addition, we propose one potential that domestic pigs show higher nitrogen isotope values in comparison with wild boar because they were possibly fed by humans.

Secondary Ion Man Spectrometry: Theory rind Applications in Geosciences (이차이온질량분석기의 원리와 지질학적 응용)

  • 최변각
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.222-232
    • /
    • 2001
  • Secondary ion mass spectrometry (SIMS) uses focused high-speed primary ions to produce secondary ions from sample surface that are analyzed through a mass filter. SIMS is often called as ion microprobe, since it offers a micrometer-scale spatial resolution. Although the precision and accuracy of SIMS are not as good as many conventional mass spectrometers, it has several advantages such as small sample-size requirement, high spatial resolution and capability of in-situ analysis. In the field of geochemistry/cosmochemistry, SIMS is widely used for (1) stable isotope geochemistry of H, C, O, S, etc., (2) geochronology of U/Th-bearing minerals, (3) lateral distribution of trace elements in a mineral, and (4) discovery of presolar grains and investigation of their isotopic compositions.

  • PDF

A short study of uncertainty for post column isotope dilution method in HPLC-ICP/MS (HPLC-ICP/MS에서 후 컬럼 동위원소 희석법의 기초적인 불확도 연구)

  • Joo, Mingyu;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.269-276
    • /
    • 2014
  • A short study for the uncertainty of post column isotope dilution method has been performed for the analysis of Selenomethionine in HPLC-ICP/MS. Major error sources studied were concentration and the flow rate of Se isotope solution, atomic weights of Se in spike and sample, and isotope ratio measured for the spiked sample. Uncertainties were obtained for each factor and the contribution for the total concentration uncertainty was 54.4% and 0.61%, 0.0072% and 0.018%, and 45.0%, respectively. The biggest contribution factor was concentration of the spike solution and the second was the isotopic ratio measured for the spiked sample solution. The mass flow rate of spike and atomic weights did not show much contribution. The calculated total uncertainty was $1.46ng{\cdot}g^{-1}$ for the standard SeMet ($126.30ng{\cdot}g^{-1}$). The experimental result was $127.09{\pm}1.46ng{\cdot}g^{-1}$ and the relative uncertainty was 1.20%.