• Title/Summary/Keyword: 조영효과 평가

Search Result 169, Processing Time 0.023 seconds

Development of Shielding using Medical Radiological Contrast Media; Comparison Analysis of Barium Sulfate Iodine Shielding ability by Monte Carlo Simulation (의료방사선 조영제를 이용한 차폐체 개발; 몬테카를로 시뮬레이션을 통한 황산바륨과 요오드의 차폐능 비교분석)

  • Kim, Seon-Chil
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.329-334
    • /
    • 2017
  • The purpose of this study is to estimating the possibility of manufacturing radiation shielding sheet by searching for environmentally friendly materials suitable for medical environment of medical radiation shielding. There are many tungsten products which are currently used as shielding materials in place of lead, but there are small problems in the mass production of lightweight shielding sheets due to economical efficiency. To solve these problems, a lightweight, environmentally friendly material with economical efficiency is required. In this study, Barium sulphate and Iodine were proposed. Both materials are already used as contrast medias in radiography, and it is predicted that the shielding effect will be sufficient in a certain region as a shielding material because of the characteristic of absorbing radiation. Therefore, in this study, we used a Monte Carlo simulation to simulate radiation shielding materials. When it is a contrast agent such as Barium sulfate and Iodine, the radiation absorption effect in the high energy region appears greatly, and the effectiveness of the two shielding substance in the energy region of the star with thickness of 120 kVp is also evaluated in the medical radiation imaging region. Simulated estimation results it was possible to estimate the effectiveness of shielding for all two substances. Iodine has higher shielding effect than barium sulfate, 0.05 mm thick appears great effect. Therefore, the Monte Carlo simulation confirms that iodine, which is a radiological contrast agent, is also usable as barium sulfate in the production of radiation shielding sheets.

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

Principles and Technical Aspects of Perfusion Magnetic Resonance Imaging (관류 자기공명영상의 원리 및 기술)

  • Jahng, Geon-Ho;Kim, Ho-Sung;Kim, Sun-Mi;Ryu, Chang-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • Perfusion magnetic resonance imaging (pMRI) is a special technique for evaluation of blood flow. Exogenous pMRI methods which are dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) use an intravenous bolus injection of paramagnetic contrast agent. In contrast, an endogenous pMRM method which is arterial spin labeling (ASL) use diffusible blood in body. In order to scan pMRI in human, technical optimizations are very important according to disease conditions. For examples, DSC is popularly used in patients with acute stroke due to its short scan time, while DSC or DCE provides the various perfusion indices for patients with tumor. ASL is useful for children, women who are expected to be pregnant, and in patients with kidney diseases which are problematic in nephrogenic systemic fibrosis (NSF). Perfusion MRI does not require any injection of radioisotopes. We expect that demand for perfusion MRI will be higher in evaluating drug efficacy and other treatment effects.

Usefulness of contrast agent involving high gadolium content for myocardial viability assessment (심근생존능검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong;Kim, Tae-Hyung;Han, Man-Seok;Lee, Ju-Hee;Min, Jung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1294-1300
    • /
    • 2013
  • The purpose of this study is to increase contrast to noise ratio(CNR) in myocardial viability test by using contrast agent which highly content gadolinium(1mmol/mL) maximizing diagnostic value. This research method that four hundred four patients were underwent the MRI scanning two hundred eighty four of them were injected commercial contrast media which have 0.5mmol/L and the rest of them were injected new contrast media(gadobutrol) which have 1mmol/mL of molarity to study the contrast difference depending on the molarity of the contrast agent signal intensities of normal ventricle and left ventricle were measured to compare and evaluate signal to noise ratio(SNR) and CNR of the images. As result, 1mmol/mL contrast agent showed higher SNR by 25.13% in myocardium and 30.74% in left ventricle. CNR was proved to be better in 1mmol/mL contrast agent by 31.29%. The results above were all statistically meaningful. Therefore, contrast agent contenting more gadolinium which was 1mmol/mL in this study, could more effectively shorten T1 relaxation time, increase the signal intensity and at the same time maximize CNR and diagnostic value. This study firstly report the usefulness of 1mmol/mL contrast agent in patients allegedly suffering cardiac diseases and it is considered to increase diagnostic value.

A Study on the Properties of Polyurethance Concrete Panel and Use for a Flooring Material (폴리우레탄 콘크리트 패널의 특성 및 바닥재로의 이용에 관한 연구)

  • 조영국;강재홍;소양섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.171-178
    • /
    • 1998
  • 본 연구는 폴리우레탄 콘크리트 패널의 바닥재로서의 이용 가능성을 검토하기 위하여 수행되었다. 따라서 각종 요구되는 성능에 부합되는 배합을 달리한 폴리우레탄 콘크리트를 제작하여 각종 물성 실험을 실시하였다. 또한 폴리우레탄 콘크리트 패널을 제작하여 직접 현장에서의 시공한 수 바닥충격음 실험을 실시, 그 효과를 평가하였다. 실험결과, 폴리우레탄 콘크리트의 성능과 코스트의 밸런스가 적절하게 확보된 최적배합비를 도출할 수 있었으며, 특히 기존 바닥구조에 비해 공동주택의 층간소음을 어느 정도 줄일 수 있고 동시에 시공공정의 단축과 단열효과로 보다 더 우수한 바닥난방구조를 제안할 수 있다.

인공현실감 기술을 이용한 자동차 주행환경의 개발

  • 윤정선;김창수;조영건;김철중
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.270-275
    • /
    • 1996
  • 본 연구에서는 인공현실감 기술을 이용하여 일종의 시뮬레이터라고 할 수 있는 자동차 주행환경을 개발하였다. 이 시스템은 Pentium PC에서 구현되었고 운전을 위하여 스티어링 휠, 클러치, 브레이크, 액 셀을 사용하였으며 속도출력을 위하여 스피드메타를 사용하였다. 이러한 입출력 장치를 하나의 통합된 모듈로 만들어서 8255 인터페이스 카드를 통하여 컴퓨터와 접속시켰다. 음향효과를 위하여 MIDI 인터페 이스, 샘플러, 스피커를 사용하였고 효과음은 샘플링하여 사용하였다. 이 밖에도 3차원 그래픽 디스플레 이를 위하여 CrystalEyes가 사용되었다. 가상세게 모델링을 위한 소프트웨어로는 Superscape VRT4.0이 사용되었다. 그래픽으로는 도심 시내 주행환경을 구현하였고, 모든 객체들은 실물 크기 비율로 그렸다. 자동차의 운전 메카니즘은 자동차 동역학을 모델링하여 계산하였다. 이러한 시스템은 주행시 운전자의 자세 및 생리신호를 측정하기 위한 환경으로 사용될 수 있으며 또한 교통안전표지나 신호등과 같은 도로 환경의 인간공학적 평가를 위해서도 사용될 수 있다.

  • PDF

심근조영심초음파에서 심장의 움직임을 보정한 비침습적 심근관류모델의 정량적 평가

  • 이재훈;김희중;정남식;임세중;김기황
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.49-49
    • /
    • 2003
  • 목적 : 심초음파는 비침습적이므로 반복적으로 정확히 심질환의 경과를 관찰하여 치료효과 및 수술시기를 정할 수 있는 검사로서 임상적으로 매우 유용하다. 실시간 심근조영심초음파에 의한 time intensity 평가는 부위별로 수행됨으로 연속적으로 위치하는 관심영역이 intensity에 있어 심장의 움직임 변화에 영향을 받는다. Time intensity 곡선의 최적의 곡선맞춤을 위해 주기적인 심장 운동 매개변수를 조합해 기존의 모델을 보정한 안정적인 측정방법을 제시한다. 방법 : 심장의 운동에 의한 특징적인 정보를 설명하기 위해 기존의 문헌에 제시된 지수 함수에 주어진 심박수로 만들어진 시간에 관한 일반적인 정형파 함수를 추가한다. C(t) = A[1 - exp($\beta$t)] + Dsine(2$\pi$ft + $\theta$) C(t): videointensity A: plateau videointensity (blood volume) $\beta$: capillary blood velocity (rate constant of rise in videointensity) t: pulsing interval (ms) D: displacement from the periodic variance of the curve (estimated motion field from the ejection point for the ratio between systole and diastole) f: heart rate $\theta$: transit time issue A $\times$ $\beta$ : myocardial blood flow 관상동맥의 관류 데이터에 대한 실험이 펄스간격에 대한 비디오 세기로 수행되었다. 그리고 이러한 결과들이 the sum of squares due to error, R square, root mean squared error로 평가되었다. 결과 : 실험결과, 주기적인 심장의 움직임과 심박출 시점으로부터의 변위를 잘 기술하고 곡선에서의 측정 점들이 예측된 심장 움직임에 따라 성공적으로 표시되었다. 뿐만 아니라 보정된 모델이 현저한 적합도의 향상을 보여주었다. 결론 : 제시된 접근방법은 각각의 측정에서 심장 운동 영역의 변화에 독립적이며 측정 시점에 의해 영향받지 않고 심근 관류의 안정적인 측정이 가능하다. 심장의 움직임에 관한 매개변수를 조합한 모델로 곡선접합을 수행함으로써 관류의 정량적 정보를 좀더 정확하게 얻을 수 있으며 임상적 이용을 가능하게 할 것으로 기대된다.

  • PDF

Effectiveness Analysis of Variable Speed Limit Systems(VSL) in Work Zones based on Meta-analysis (메타분석을 이용한 공사구간 가변속도제한시스템(VSL) 효과분석)

  • Jo, Young;Youn, Seok-min;Oh, Cheol
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.91-103
    • /
    • 2016
  • The work zone traffic management is of keen interest because the unstable traffic stream in work zones leads to not only less productive traffic operational efficiency but also negative impacts on traffic safety. A promising method to address such issues is variable speed limit systems(VSLS). VSLS is expected to increase in throughput and to enhance safety by diminishing the crash potential. In addition, the usefulness of VSLS has been demonstrated by significant amount of existing literature. The objective of this study is to identify the effectiveness of VSLS based on a meta analysis technique. Throughput and travel speed were used as measures of effectiveness for VSLS in terms of the operational efficiency and safety respectively. Results showed that approximately 16.4% increase in throughput and 16.5% decrease in travel speed were obtainable by VSLS. The outcomes of this study would be useful in developing technologies and polices for better operation of VSLS.

Analytical Modelling for Recarbonation Process of Concrete Repaired with Patching Repair Material (단면복구재로 보수된 콘크리트의 재탄산화 과정에 대한 분석적 모델링)

  • Do, Jeong-Yun;Kim, Doo-Kie;Song, Hun;Jo, Young-Kug
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.89-96
    • /
    • 2010
  • This study presented the analytical evaluation model effective in the concrete structure repaired with a patching material. The model considered the effect of the repair material on carbon dioxide penetration into the repaired concrete as evaluating the remaining service life of the CO2-deteriorated concrete structure after repair. The diffusion profiles of carbon dioxide as well as the carbonated concrete were effectively able to be modelled with analytical method based on Fick's 1st diffusion law. The evaluation of the model equation showed the good result and rational process quantitatively and numerically to evaluate the remaining service life of the repaired concrete structure after repair.