• Title/Summary/Keyword: 정착구

Search Result 176, Processing Time 0.038 seconds

Development and Analysis of Unbonded Post-tensioned Anchorage for Single Tendon (비부착식 단일 강연선용 포스트텐션 정착구 개발 및 응력해석)

  • Lee, Young Hak;Cho, Yong Woo;Kim, Min Sook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • In this paper, an unbonded post-tensioning anchorage for a single-stranded wire that allows more efficient stress distribution in the post-tensioned anchorage zone was developed by using a finite element analysis using a commercial program. The stress analysis was carried out using a 3D model in the anchorage zone of the concrete member using the developed anchorage. The result of analysis ensured that the developed anchorage reduced the maximum bursting stress in anchorage zone compared to the case of existing anchorage and the location where maximum bursting stress also occurred closer to the anchorage. Bursting force was calculated using AASHTO, modified $M{\ddot{o}}rsch$ and Stone. As a result, it was concluded that an effective reinforcement design of the anchorage zone can be designed by modified $M{\ddot{o}}rsch$.

Study on Bursting Stress in Anchorage Zone of Prestressed Concrete Using Circular Anchorages (원형 정착구를 적용한 프리스트레스트 콘크리트 정착구역의 파열력에 관한 연구)

  • Choi, Kyu-Hyung;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.3-12
    • /
    • 2015
  • Bursting stress in anchorage zone of post tension girder can be estimated based on Guyon's equation. The major parameters in calculating bursting stress are prestressing force and the distance ratio between concrete edge and anchorage plate. Although Guyon's equation can be applied to calculate bursting stress for rectangular typed as well as circular typed plate, there is some limitation of accuracy due to 2 dimensional analysis. Therefore this study is proposed to suggest a bursting stress equation based on 3 dimensional finite element method.

Study on numerical analysis for cable anchorage device of arch type cable stayed bridge for light railroad (경전철용 아치형 사장교의 보강형 정착구에 대한 수치해석 연구)

  • Kong, Byung-Sueng;Jeong, Ji-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.619-622
    • /
    • 2011
  • 케이블 정착구 검토를 위해서 사장교 전 체계를 모델링하는 것은 전체모델링 해석시 많은 노력과 시간이 요구되고 해석결과의 분석 또한 어려움이 많다. 따라서 문제가 예상되는 부분만을 국부 상세해석하여 구조적 거동을 정확히 파악하는 것이 필요하다. 케이블 정착부에는 여러 보강재들로 구성되어 있어 국부해석에 어려움이 있다. 따라서 실제와 가능한 한 근접하도록 모델링을 하고 전체 구조물의 거동을 국부 상세모델에 적적히 반영할 수 있도록 경계조건을 설정하는 것이다. 본 논문에서는 부산 지하철 4호선의 아치형 사장교를 국내 범용 구조해석 프로그램인 MIDAS/CIVIL을 이용하여 아치리브와 거더정착구 모델링을 실시하였다. 해석 후 해석의 타당성을 검토하고 정착부의 안전성을 확보할 수 있는지 검토 분석 하고자 한다.

  • PDF

The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands (2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능)

  • Kim, Sun-Woo;Lho, Byeong-Cheol;Lim, Jung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.63-71
    • /
    • 2018
  • Strands with ultimate strength of 2,400 MPa was developed and applied in the KCI Code and the KS standard. A high-strength prestressed strand to be applied to a structure, a suitable anchorage system should be used together. Recently, a post tension anchorage for 2,400 MPa strands was developed. but there is not much research on performance evaluation. Therefore, in this study, structural analysis of local zone with 9 strands, 15 strands, and 19 strands anchorage were investigated respectively, which are most widely used for post tensioning anchorages with 2,400 MPa strands, according to PTI anchorage zone design method, and Load transfer performance from ETAG013 and/or KCI-PS101 was evaluated. Furthermore, the adequacy of the test was also analyzed by nonlinear numerical analysis. As results, the anchorages with 2,400 MPa strands satisfied the structural performance of the local area and satisfied the load transfer performance condition.

Fatigue Test of Domestic CFRP Tendon and Anchorages (CFRP 긴장재 및 정착구의 피로시험)

  • Jung, Woo-Tai;Park, Young-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.421-422
    • /
    • 2009
  • This study investigated the fatigue test of domestic CFRP Tendon and anchorages. Test results revealed that fatigue capacity of anchorages with swage-type and bond-type satisfied the specifications. In domestic CFRP Tendon, fatigue strength of 1 million and 2 million cycle showed 992, 871MPa, respectively.

  • PDF

Structural Analysis of a Cable Anchor System for a Cable-Stayed Bridge over the Sea (해상 사장교의 Pipe형 케이블 정착구에 관한 구조해석)

  • KONG BYUNG-SEUNC;HONG NAMSEEG
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.34-42
    • /
    • 2005
  • The cable connection zone of the cable-stayed bridge transfers deal-load, live-load, and second-load to the cables on the structural joint zone of the cables and the main girders are the most critical parts in which big cable tensile forces are generated by those loads. Therefore, it is necessary to thoroughly check the main girder, structurally to secure the required stability. Because of the heavy tensile force of cables linked in the connection zone of the cable-stayed bridge, locally concentrated stress, as well as the dispersion of stress, occurs in the structurally contacted point of cable and main girder thus, we need to make a thorough investigation through a detailed structural analysis. Directly delivering the tensile force to the connection zone of the cable, the consequently big effect in the tensile force fluctuation caused by the live-load will make it necessary to review the fatigue strength. As the connection zone of the cable is designed to resist the tensile force of the cable, which is applied to a connecting section as a concentrated force, thick plates are used. These plates are frequently made of welded structure, thus, the investigation of the welding workability is inevitable.

Development and Performance Test for Unbonded Post-Tensioned Anchor (비부착 강연선에 대한 포스트텐션 정착구 개발 및 성능 시험)

  • Cho, Ah Sir;Jo, Yeong Wook;Jeon, Byong Kap;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2015
  • An unbonded post-tensioned anchor using a 15.2 mm diameter 7-wire strand was developed based on finite element analysis and experimental testing. In order to evaluate its performance, static load tests and load transfer tests were conducted following KCI-PS101. The static load tests and additional strand tensile tests confirmed that the developed anchor had a capacity more than nominal tensile strength of a 7-wire strand without any damage or deterioration. According to the result of load transfer tests for many different reinforcing details, specimens with no additional reinforcing bars sustained at least 1.64 times the nominal tensile strength of the strand.

Ultimate Behavior of Steel Beam Strengthened with External Tendonand Cylindrical Anchorage (원통형 정착구를 사용하고 외부 긴장재로 보강된 강재보의 극한거동)

  • Choe, Dong-Ho;Jeong, Sang-Hwan;Jung, Jae-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.102-110
    • /
    • 2006
  • This paper examines experimentally the ultimate behavior of I-type steel beam strengthened with external tendon and cylindrical anchorage and analyzes the strengthening effect on the parameters such as initial tendon force, eccentricity, number of strands, and strand areas. The experiment demonstrated that increasing the number of strands, strand areas and eccentricity is more effective than increasing initial tendon force. The proposed cylindrical anchorage system has advantages in applying these parameters. The results showed that the cylindrical anchorage system is efficient and applicable to strengthen steel beam.

Anchorage Behavior of Bi Prestressed Concrete Girders (프리스트레스트 콘크리트거더의 정착구 거동 분석)

  • Lee, Pil-Goo;Kim, Choong-Eon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.361-364
    • /
    • 2008
  • This study was performed to estimate the anchorage behavior for Bi Prestressed Concrete Girder(Bicon girder) which could introduce effectively prestressed forces into concrete girders. A bicon girder is manufactured by means of introducing pure bending moment that prestress simultaneously the compressive member(steel bar) and the tensile member(steel tendon). Therefore, the steel bar and the steel tendon must be unified in both ends and compressive and tensile force be offset. Anchorage dimension of 6 test specimens was designed under PTI specification which defined maximum stress and deformation to estimate structural behavior. Test results showed that the stress and the deformation of anchorage were within limits if the steel bar behaviored elastically.

  • PDF

Effect of Cattle Slurry Applications on the Infertilie Sloped Land (경사 척박지에서 목초정착에 미치는 액비시용효과)

  • 최선식;김영진;윤세형;육완방
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.14 no.3
    • /
    • pp.230-237
    • /
    • 1994
  • This experiment was carried out to determine the effects of cattle sluny and zeolite application for the improvement of germination and establishment of grasses in infertile slopped land. The best establishment and winter survival of grasses were observed in the plot of cattle slurry application. The dry matter yield of grasses was increased by 12% in the plot of compaction + cattle slurry application when compared with control. Alteration effect of soil pH was v q high and the content of organic matter was increased by addition of the soil conditioner.

  • PDF