• Title/Summary/Keyword: 정온도

Search Result 293, Processing Time 0.032 seconds

Study on Adequate Positioning of Environmental Noise Automatic Measuring System in Busan (부산시 환경소음 자동측정망 설치위치의 적정성에 관한 연구)

  • Kim, Hwa-Il;Han, Kyoung-Min
    • Journal of Environmental Policy
    • /
    • v.8 no.1
    • /
    • pp.31-48
    • /
    • 2009
  • To install and operate the Automatic Noise Monitoring Networks reasonably, which able to monitoring environmental noise continually, is an important issue for making decision to urban environment. Noise level is determined by regional environmental factors, that affected by complex urban environment. Therefore, accurate measurement of environmental noise level has top priority to establish and promote appropriate environmental policies. Currently, Automatic Noise Monitoring System is installed for grasping the environmental noise level and preparing basic data for constructing noise-reduction policies. However, this measurement data is recognized not to be able to reflect a sensory noise. The main reason is the lack of reliable measurement data and unreasonable installation site. The main point of this research ought to be the analysis of installed site of noise monitoring system in Busan.

  • PDF

An Expremental Study on Connections Friction Test of Improvement for Coastal Environment Block (Coastal Environments 블록의 개발을 위한 연결부 마찰 실험)

  • Kim, Chun-Ho;Kim, Sang-Hoonq
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.49-52
    • /
    • 2008
  • The plain and simple shape water front structure were designed and installed for wave protection and wave resistance. But the installation of these plain and simple structure cause deficiency of environmental affinity. Also the resonance phenomena from the reflective wave and shipwave of the harbor incident wave caused high tide and wave, consequently maintaining the tranquility of inside harbor, give difficulty for mooring the ship and loading-unloading, increase the possibility of ship collision at the quray wall and landing place To solve these problems, we develop the environmentally friendly wave dissipation block. And installation efficiency, stability of the blocks through experiment of C.E Block Joint.

  • PDF

Effect of the Re-oxidation Times on the PTC Properties of $BaTiO_3$ with Sm Contents (Sm 함량을 달리한 $BaTiO_3$계의 재산화 시간에 따른 PTC 특성 변화)

  • Baek, Seung-Kyoung;Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.179-179
    • /
    • 2008
  • $BaTiO_3$를 기본조성으로 하는 PTC 써미스터는 Curie 온도이상에서 저항이 급격히 상승하는 산화물 반도체 세라믹이다. 이러한 성질을 이용하여 degaussing 소자, 정온 발열체, 온도센서, 전류 제한소자 등 상업적으로 여러 분야에서 연구되고 있다. 또한 원가절감 등을 위하여 Ni 내부전극을 사용하여 환원 분위기에서 소결하는 칩 타입에 대한 연구가 진행되고 있다. 본 연구에서는 Sm 함량(0.1at%~1.0at%)을 달리한 $BaTiO_3$(Si, Mn, Ca) 계를 선택하여 3%$H_2/N_2$ 분위기에서 1200~$1260^{\circ}C$, 2h 소결한 후 공기 중에서 재산화 처리하고 재산화 시간에 따른 PTC 특성 변화에 대하여 고찰하였다. 재산화 온도와 시간은 각각 $800^{\circ}C$와 0.5h~10h으로 하였다. Sm 함량을 달리하여 환원 분위기에서 소결한 시편의 미세구조와 PTC 특성과의 상관관계를 관찰한 결과, 소결온도가 낮을수록 PTC 특성은 좋아졌으며, 상온 비저항은 Sm 함량이 높아질수록 낮아졌다. 또한 Sm 함량이 높아질수록 jumping ratio$(R_{max}/R_{25^{\circ}C})$는 낮아졌다. 재산화 시간에 따른 PTC 특성은 다소 떨어졌지만 소결온도에 따라 달리 나타났다. Jumping ratio$(R_{max}/R_{25^{\circ}C})$는 Sm을 0.7 at% 첨가한 계에서 재산화를 1시간 처리한 시편에서 가장 우수하였다.

  • PDF

Management Strategies for Electromagnetic Fields in Electric Power Lines (고압선로에서 발생하는 전자기장의 위해성 관리 방안)

  • 전인수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1017-1023
    • /
    • 2003
  • Recently, the use an electric apparatus has brought into concerns about health risks from exposure to electromagnetic fields. During the last 2 decades, a number of epidemiological studies have explored the association between childhood leukaemia and residential exposure to power-frequency electromagnetic fields. Several studies have suggested that there is a small excess leukaemia risk with magnetic field exposure above 2 mG. A number of governmental and international organizations have developed exposure gudelines. The most rigid regulation with exposure levels for the elementary school and hospital has been enacted by Switzerland. Although there is no convincing supportive laboratory evidence, and the absence of a plausible biological mechanism of disease causation limits, governments are increasingly called on to adopt precautionary approaches to regulating electromagnetic field exposures. The government would need to establish the policy for electromagnetic fields and continually to be concerned about possible health risks from exposure to electromagnetic fields.

Health Effects of Apartment Noise (층간소음의 건강영향)

  • Park, Young Min;Kim, Kyoung Min
    • Journal of Environmental Policy
    • /
    • v.14 no.1
    • /
    • pp.113-134
    • /
    • 2015
  • In new housing demand, proportion of occupied multi-housing is 89.9% (statistics from 2013). In this way, with many generations living together, apartment noise disputes between the neighbors are continuously rising. The apartment noise problem in Korea is at a very serious level worldwide (about 88% of the population is experiencing stress due to apartment noise). On the other hand, the government has strengthened the regulations (such as the thickness of the floor and floor impact sound reduction performance, etc.) and promoted a resolution of its own for each multi-housing estates for mediating disputes on apartment noise. However, such physical regulations and passive management policies still presents a limit to the dispute mitigation of apartment noise. Also, in order to improve the quality of life in living spaces, policy on health effects of apartment noise should be provided. Therefore, we investigated a case study of the noise exposure-human body reaction to analyze the effect of noise on health. On the basis of this, the health effects according to the exposure period of apartment noise were considered.

  • PDF

A Study on Protective Control System for Electrical Fire using Characteristics of SCR and Multilayer-Type PTC Thermistor (SCR과 적층형 PTC 서미스터의 전기적 특성을 이용한 전기화재 보호제어시스템에 관한 연구)

  • Kwak Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.31-35
    • /
    • 2006
  • This paper is studied on a protective control system for electrical fire used electrical characteristics of SCR and multilayer-type PTC thermistor. The PTC thermistor has characteristic or positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with $BaTiO_{3_}$Ceramics of positive temperature coefficient. Also PTC shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point. This paper is proposed on a protective control system used multilayer-type PTC which is protected from electrical fire due to electric short circuit faults or overload faults. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

Development on Electrical Fire Prevention System of Small Size and High Speed by using PTC Thermistor (PTC 서미스터를 이용한 소형 고속응성의 전기화재 방재시스템 개발)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2008
  • This paper is studied on a prevention system for electrical fire and electrical faults by using electrical temperature characteristic of PTC thermistor. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with $BaTiO_3$ ceramics of positive temperature coefficient. Also PTC shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point. This paper is proposed on a protective control system used with temperature sensor of PTC thermistor. The proposed prevention system will prevent electrical fires due to electric short circuit faults or overload faults. And the prevention system will solve the problems that circuit breakers to be commonly used at existing are happened frequently electrical fires and electrical disasters due to incapable operation, weak reliability and low speed response. Some experimental results of the proposed apparatus are confirmed to the validity of the analytical results.

  • PDF

Temperature Characteristics of Solid State Flow Velocity/Mass Sensor (반도체형 유속/유량센서의 온도특성)

  • Choi, Jai-Gun;Kim, Hyung-Pyo;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.29-36
    • /
    • 1995
  • A constant solid state flow velocity/mass sensor has been fabricated and its characteristics were measured according to flow velocity and fluid temperature. Parameters of the sensor circuit were obtained by simulation using finite difference method. Sensitivity was 10mW/(cm/sec) in the range of flow velocity 0-45cm/sec and response time was within two seconds. For the experiment of fluid temperature variation, the sensor output was compensated at the rate of temperature variation $0.1^{\circ}C/min$, however, with the rate of $0.2^{\circ}C/min$ it took two minutes to be compensated. Since it is not quite often to have such a rate of temperature variation of $0.2^{\circ}C/min$ or more, the developed sensor output can be used for most applications to detect small amount of flow-rate.

  • PDF

Effect of Storage Conditions, Rice, Cooker and Oil Types on the Changes of Resistant Starch Contents of Cooked Rice (저장조건, 쌀, 조리기구와 유지 종류가 밥의 저항전분 함량 변화에 미치는 영향)

  • Ren, Chuanshun;Kim, Ji Myoung;Park, Sara;Jeong, On Bit;Shin, Malshick
    • Korean journal of food and cookery science
    • /
    • v.32 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • The changes of resistant starch (RS) contents of cooked rice with soybean and coconut oils under different storage conditions were investigated and RS contents were compared between the rice and cooker types. The japonica (Hopyeong) and the indica (Thailand) type rice were cooked (washed rice: water = 100: 130) using an electric cooker and a saucepan. The coconut oil and soybean oil (3%, based on rice, w/w) were added into cooking water before heating. The RS contents of freeze-dried cooked rice powders (newly-cooked rice, stored for 12 h in the refrigerator, microwave heating after storage for 12 h in the refrigerator) were measured by the AOAC method. The RS contents of cooked rice using a saucepan were higher than those using an electric cooker. The indica type cooked rice had a higher RS content than the japonica type cooked rice, regardless of storage conditions. However, addition of oil before cooking rice resulted in increased RS content on storage in the refrigerator. The highest RS content of the cooked indica type rice with soybean oil ($5.89{\pm}0.22%$) that was stored for 12 h in the refrigerator was analyzed. The results suggested that the cooked rice formed retrograded (RS3) and amylose-lipid complex (RS5) type RS; furthermore, the RS content is affected by storage conditions, rice, cooker and oil types.

Selection of a Fire Detector for Wood Cultural Property (목조문화재 건축물 구조에 따른 화재감지기 종류 선정에 관한 연구)

  • Roh, Sam-Kew;Yoon, Hyoung-Uk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.88-93
    • /
    • 2016
  • A fire detector installed in wood cultural properties has not have selected the detector type appropriate for the features of cultural properties and the structure of wood fire after the fire in Sungnyemun-Gate since 2008. Applying wooden cultural properties different from the general architecture of the structure and fire characteristics is difficult. Therefore, buildings were classified into four shape types and field survey and wooden architecture structure characteristics to identify the problems of the detectors installed on wooden cultural property buildings. The problems appeared to lack the adaptability to external fire detection sensor selection and missing fire detectors installed in accordance with the place. To solve the problem, the closed and open space of the rooms used a smoke detector, outdoor select flame or fixed temperature linear detector to solve the problem.