• Title/Summary/Keyword: 정수시설설계

Search Result 63, Processing Time 0.027 seconds

Nonlinear Analysis of Compressive Flange Based on Folded Plate Theory (Folded Plate Theory에 의한 압축플랜지의 비선형 해석)

  • Jung, Soo-Hyung;Shim, Jae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.169-178
    • /
    • 2008
  • Compressive flanges of steel box girder is designed based on the ultimate strength behavior of sub-panel which is enclosed with longitudinal stiffeners and transverse stiffeners on appropriate safety factor. However, it is rational that the ultimate strength is calculated considering the various factors such as number and stiffness of longitudinal stiffener, spacing of transverse stiffener, initial deformation and residual stress distribution. In this study, an analysis program based on Folded Plate theory is developed considering the geometric effects and the material nonlinearity. The analysis program is applicated to the steel box girder bridges which is really constructed in domestic.

Intercepted flow equation at grate inlet on road (도로 빗물받이 유입구의 차집유량 산정식)

  • Kim, Jung Soo;Kwak, Sang Ho;Ryu, Taek Hee;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.537-549
    • /
    • 2016
  • The grate inlets generally were installed to intercept surface runoff on the roads and intercepted flow was drained to the underground sewer system. The equation of interception flow was used to determine the size and spacing of grate inlet on the roads. Therefore, it is necessary to analyze the interception capacity of grate inlet. Hydraulic experimental apparatus which can be changed with the longitudinal slopes(2, 4, 6, 8, 10%) of street, the transverse slopes(2, 4, 7, 10%), and the lengths(50, 100, 150cm) of grate inlet was installed for this study. The range of the experimental discharges were calculated with change of road lanes(2, 3, 4) and design frequencies(5, 10, 20, 30year). As the transverse slope increased, it led to the increase of interception capacity at grate inlets. The long lengths of grate inlet with direction of flow increased the interception capacity by the increase of side inflow. On the basis of the hydraulic model experiment results, the empirical equations for calculation of the interception capacity were derived with regression analysis. As a result of comparison with equations, the suggested equation of this study was estimated reasonable one for increased design frequency. Therefore, this study can suggest the basic data for design of drainage facility at road.

A Analytical Study on Seismic Performance of Stainless Water Tank using Lead Rubber Bearing (납고무받침을 이용한 스테인리스 물탱크 내진성능에 관한 해석적 연구)

  • Kim, Hu-Seung;Oh, Ju;Jung, Hie-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.230-236
    • /
    • 2018
  • Earthquakes over 5.0 on the Richter scale have recently occurred in Korea, which has led to interest in the seismic safety of structures. If a water storage facility is damaged by an earthquake, the water could leak, and the insufficient water would make fire suppression difficult. Therefore, a water storage facility should satisfy safety requirements for earthquakes. In this study, the seismic performance of a water tank was improved by installing a lead rubber bearing between the foundation and the tank. It designed the lead rubber bearing available to the existed concrete foundation. ANSYS was used for modeling to consider the interaction between the fluid and structure of the tank and the hydrostatic and hydrodynamic pressure using four seismic waves. In the case of hydrostatic pressure at 2.5 water level, full level, the same stress appeared irrespective of whether the seismic isolation was installed. When hydrostatic pressure and hydrodynamic pressures are applied at the same time, the seismic-isolated water tank showed less seismic force, and the damping ratio was lower than that of general seismic isolation. This occurred because the weight of the water tank is much smaller than the stiffness of the seismic isolation. The result is expected to be used for further research on seismic capacity evaluation for water tanks.

Analysis of the road surface runoff at the continuous section (연속구간 도로의 표면흐름 분석)

  • Kim, Jung Soo;Jo, Jun Beom;Kim, Soo Youl;Lee, Sung Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.242-242
    • /
    • 2020
  • 도시화와 산업화에 따른 유출환경의 변화로 인해 도심지에서 발생하는 대부분의 유출은 도로표면을 따라 이동하고 도로변에 설치된 빗물받이에 의해 배수된다. 이 때 빗물이 원활하게 배수되지 않아 노면수가 정체되고, 이 노면수가 인근 주택지로 유입되어 침수 피해가 발생한다. 이러한 현상은 유출량이 집중되는 도심지 저지대에서 주로 발생하며 설계 한도를 초과하지 않는 정상적인 강우 조건에서도 빈번히 나타나고 있다. 이는 최근의 기후 변화로 인한 집중 호우 등을 고려하여 설계 기준이 지속적으로 조정되어야 함과 동시에 도로 노면수의 배수 능력 평가를 위한 실제적인 연구가 이루어져야 한다는 필요성을 나타내고 있다. 특히 도로 빗물받이의 효율은 주로 종경사 및 횡경사 등의 도로 조건, 표면 유출 우수량, 빗물받이의 형상 등에 의존한다. 그러므로 상향된 설계빈도 및 도로 조건을 고려한 도로 표면 유출에 대한 흐름 분석과 빗물받이 특성을 고려한 실증연구의 분석 및 설계 해석 알고리즘의 개발이 시급한 실정이다. 본 연구에서는 도로 노면수의 배수 능력 증대를 위해 연속 설치된 빗물받이 조건 및 도로 경사조건을 고려하여 도로 배수시설의 표면 유출 모델 설계 알고리즘을 개발하였다. 표면 유출 유량은 도로의 차선(2~4차선), 경사(종경사 2~10% 및 횡경사 2~10%) 및 설계빈도(최대 30년)를 고려하였으며 유량이 노면 진행방향을 따라 연속적으로 증가하는 부등류 흐름 해석 방법을 채택하였다. 또한, 빗물받이 설치간격(L)과 도로의 폭(W)의 곱으로 계산되는 단순 직사각형 형태의 노면 형상이 아닌 도로 종경사 및 횡경사에 따른 유달거리를 산정하여 평행사변형 형태의 노면 형상을 계산하고 이에 따른 면적(A), 도달시간(tc) 및 강우강도(I)를 산정하였다. 이와 같은 1차원 흐름분석을 통해 도로 표면흐름 및 빗물받이 설치 간격을 제시하고 기존의 제시된 빗물받이 설치 간격과 비교하여 본 연구에서 제시한 설계 알고리즘을 검증하였다. 또한, 수리 실험을 통해 측정된 빗물받이 차집효율을 이용하여 연속 구간에서의 도로 표면 유출 모델의 적용성을 제시하였다. 이는 빗물받이 유입구를 통해 모든 유량이 유출된다고 가정하고 단독 구간에서의 수리분석 결과만을 고려하여 이를 확장시켜 개발된 기존의 도로 표면 유출 모델을 보완할 수 있을 것으로 기대된다. 본 연구에서 제시하고 있는 설계 알고리즘을 적용한다면 도로 전체 구간에서의 흐름 변화 분석과 배수효율의 정량적인 분석이 가능하므로 향후 도로 표면 침수 피해 저감 및 배수능력 증대를 위한 실증적이고 정량적인 분석 방법이 될 것으로 판단된다.

  • PDF

Design of West Seoul Lake Park in Reusing the Sin-Wol Filtration Plant (신월정수장을 재활용한 서서울호수공원 설계)

  • Choi, Shin-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.24-30
    • /
    • 2009
  • The Sin-Wol filtration plant was an urban infrastructure and off-limits to the public. It is recreated as a representative experiential theme park in the southwest area. It has not only provided places to relax, but has made a new model of urban park by reusing advantages. The current lack of easy access into the park area almost isolates it like a green island. The neighborhood surrounding the park does not have many physical connections to the park to be able to use it. By connecting the surrounding communities with numerous access points into the park and linking the hiking trails and bike paths, the city's need for open space and recreation would be far better satisfied than before. This would allow for the use of the valuable assets of the existing forest and open space.

Reliable Evaluation of Dynamic Ground Properties from Cross-hole Seismic Test using Spying-loaded Lateral Impact Source (스프링식 횡방항 발진 크로스홀 탄성파 시험을 통한 지반 동적 특성의 합리적 산정)

  • Sun, Chang-Guk;Mok, Young-Jin;Chung, Choong-Ki;Kim, Myoung-Mo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.4 s.50
    • /
    • pp.1-13
    • /
    • 2006
  • Soil and rock dynamic properties such as shear wave velocity $(V_s)$, compressional wave velocity $(V_p)$ and corresponding Poisson's ratio (v) are very important geotechnical parameters in predicting deformational behavior of structures as well as practicing seismic design and performance evaluation. In an effort to measure the parameter efficiently and accurately, various bore-hole seismic testing techniques have been, thus, developed and used during past several decades. In this study, cross-hole seismic testing technique which is known as the most reliable seismic method was adopted for obtaining geotechnical dynamic properties. To perform successfully the cross-hole test for rock as well as soil layers regardless of the ground water level, spring-loaded source which impact laterally a subsurface ground in vertical bore-hole was developed and applied at three study areas, which contain four sites composed of two existing port sites and two new LNG storage facility sites. The geotechnical dynamic properties such as $V_s,\;V_p$ and v with depth from the soil surface to the engineering and seismic bedrock were efficiently determined from the laterally impacted cross-hole seismic tests at study sites, and were provided as the fundamental parameters for the seismic performance evaluation of the existing ports and the seismic design of the LNG storage facilities.

Evaluation of dynamic ground properties using laterally impacted cross-hole seismic test (횡방향 발진 크로스홀 탄성파 시험을 이용한 지반의 동적 특성 평가)

  • Mok Young-Jin;Sun Chang Guk;Kim Jung-Han;Jung Jin-Hun;Park Chul-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.155-175
    • /
    • 2005
  • Soil and rock dynamic properties such as shear wave velocity (VS), compressional wave velocity (VP) and corresponding Poisson's ratio ( v ) are very important geotechnical parameters in predicting deformational behavior of structures as well as practicing seismic design and performance evaluation. In an effort to measure the parameter efficiently and accurately, various bore-hole seismic testing techniques have been, thus, developed and used during past several decades. In this study, cross-hole seismic testing technique which is known as the most reliable seismic method was adopted for obtaining geotechnical dynamic properties. To perform successfully the cross-hole test for rock as well as soil layers regardless of the ground water level, spring-loaded source which impact laterally a subsurface ground in vertical bore-hole was developed and applied at three study areas, which contain four sites composed of two existing port sites and two new LNG storage facility sites. The geotechnical dynamic properties such as VS, VP and v with depth were efficiently determined from the laterally impacted cross-hole seismic tests at study sites, and were provided as the fundamental parameters for the seismic performance evaluation of the existing ports and the seismic design of the LNG storage facilities.

  • PDF

Evaluation of Uplift Force Acting on Foundation of Underground Structure (지하구조물 하부에 작용하는 양압력 평가)

  • Kim, Jin-Man;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.662-671
    • /
    • 2020
  • The uplift force acts directly on the foundation and causes a building to float to the upper ground. To examine the stability of a structure according to the uplift force, four sites (Paju, Anyang, Osan, and Gangneung) were selected, and sensors were installed on the foundations for the field tests. The rainfall characteristics were analyzed around June~September, and the changes in the water level of the adjacent river were considered. The maximum uplift force except for Gangneung did not exceed 72% of the water pressure when the groundwater level was up to the surface. On the other hand, the maximum uplift force in Osan was approximately 67%, but the reliability was slightly inferior because the difference from the average (46%) was large. The minimum uplift force was within 10% except for Anyang (~ 41%). At the Gangneung site on soft rock where the permanent drainage facility was installed before the measurement, the maximum and minimum uplift force was approximately 14% and 3.5%, respectively. Based on the measurement results, the possibility of overdesigning or underdesigning comes from the design by the hydrostatic pressure when the groundwater level is up to the surface.

Impact Resistance Characteristics of Cementitious Composites Subjected to High-velocity Projectiles with Reinforcement Types (고속 발사체와 충돌한 시멘트복합체의 보강재 종류에 따른 내충격 특성 연구)

  • Seok, Won-Kyun;Kim, Young-Sun;Lee, Yae-Chan;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.261-272
    • /
    • 2023
  • This research concentrates on the potential explosion hazards that could arise from unforeseen accidents in the rapidly proliferating hydrogen refueling stations and Energy Storage System(ESS) facilities. It underscores the pivotal role of structural protection technology in alleviating such risks. The research contributes primary data for the formulation of structure protection design by assessing the impact resistance across various reinforcement techniques used in cement composites. The experimental results elucidate that reinforced concrete, serving as the quintessential structural material, exhibits a 20% advancement in impact resistance in comparison to its non-reinforced counterpart. In situations typified by rapid loads, such as those seen with high-velocity impacts, the reinforcement of the matrix with fibers is demonstrably more beneficial than local reinforcement. These insights accentuate the importance of judiciously choosing the reinforcement method to augment impact resistance in structural design.

Planning and Establishment of Sejong City Smart City (세종시 스마트시티 구상 및 수립 방안)

  • Park, Jungsu;Jung, Hanmin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.161-163
    • /
    • 2021
  • This urban centralization is expected to develop rapidly, with 75% of the population living in the city by 2035. Large cities are becoming unsustainable due to side effects such as environmental pollution, severe traffic jams, excessive energy depletion, and destruction of the natural ecosystem. In addition, the happiness index of citizens of large cities is also falling because of high crime rates and safety accidents, the work-life imbalance caused by inequality and polarization, and overly competitive education. To solve this problem, Smart City, an IT-based future city model, was born. The Korean government is also actively attempting to improve urban competitiveness and promote sustainable development through efficient construction and operation of smart cities as a national focus project. To support the effort, we review the basic directions and strategies of Sejong City's Smart City service infrastructure based on the comprehensive national land plan, Smart City plan, and Smart City strategy plan.

  • PDF