• Title/Summary/Keyword: 정상상태 성능

Search Result 732, Processing Time 0.03 seconds

A Study on Perception about Body Image, Dietary Attitude, Dietary Self-Efficacy and Nutrient Intake of High School Students in Busan (부산지역 일부 고등학생의 체형 인식도, 식생활 태도, 식이 자기 효능감 및 영양섭취상태에 관한 연구)

  • 이정숙;윤정원
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.2
    • /
    • pp.295-301
    • /
    • 2003
  • This study was carried out to investigate perception about body image, dietary attitude, nutrient intake and dietary self-efficacy of high school students in Pusan. A questionaire survey was distributed among 491 high school students. The survey was conducted from April 8 to April 22 in 2002. The results are summarized as follows. Forty percents of the underweight group, 53.9% of the normal weight group, 61.8% of the overweight group and 48.2% of obesity group have correct perception about their body image. Most of the students were concerned with their body image and weight control. Obesity of parents was significantly correlated with obesity of the subjects (p<0.01). The higher obesity rate, the lower dietary self-efficacy. The higher dietary self-efficacy, the higher dietary attitude. There was a significant positive correlation between the education level of their parents and dietary attitude of the subjects (p<0.01) and a significant negative correlation between obesity rate of their mothers and dietary attitude of the subjects (p<0.01). Dietary attitude scores showed no significant difference among the groups. Intakes of most nutrients, except protein, niacin and vitamin C, were lower than those of the recommended dietary allowances for Koreans. Therefore, proper nutrition education is required to improve their nutritional status and dietary self-efficacy.

A study on Military Adapting Method of Non-stop Server using Clustering (클러스터링을 이용한 무정지서버의 군적용방안에 관한 연구)

  • Lee, Kyung-Chan;Lee, Sang-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11c
    • /
    • pp.2383-2386
    • /
    • 2002
  • 많은 ISP업체와 서버 관리자들은 자신의 시스템 향상을 위하여 많을 비용을 쏟아 붇고 있지만 그 결과는 비관적이다. 지금까지는 하드웨어적인 성능만을 고려하였으나, 최근에는 리눅스를 탑재하여 낮은 가격과 높은 가용성을 가지면서, 증가하는 네트워크 요청에 효과적으로 대응하기 위한 해결책으로 여러 대의 호스트로 구성되는 클러스터링 기술이 각광을 받고 있다. 또한 클러스터는 저렴한 호스트들로 구성되므로 구축 비용이 절감되는것 뿐만 아니라, 일부 호스트가 고장 나더라도 다른 호스트는 네트워크 작업 분담을 재설정하여 정상적으로 동작함으로 가용성이 항상 유지될 수 있다는 것을 보여준다. 최근 군에서도 정보화 과학화의 열풍에 힘입어 그 어느때보다도 업무의 전산화, 정보화에 박차를 가하고 있는 실정이다. 이로 인한 군업무에 적용되는 중대형 서버의 증가와 1인 1PC정책에 의한 클라이언트의 증가, 네트웍 인프라 구축에 심혈을 기울이고 있다. 그러나 사용자의 요구만큼 군환 경하에서의 정보화 업무를 감당하는 서버의 역량은 제한이 있다. 군업무의 특수성에 비추어 볼때에도 사회의 금융업무와 마찬가지로 중단없는 서비스의 수행과 서버의 안정화는 군전산의 가장 중요한 요소중의 하나임에 불구하고 아직까지도 현실성은 많이 미비한 상태이다. 본 연구는 이와 같은 문제를 해결하기 위하여 NAS와 SAN개념(네트웍기반)을 도입하여 군 서버 구축 새로운 패러다임을 제공하여 업무의 통폐합과 함께 서버의 통폐합의 전초단계인 무정지 클러스터링 서버의 구축방안을 제시하여 군정보화, 과학화의 초석을 다지는 계기로 삼고자 한다.위상변화에 대한 적응성을 높일 수 있도록 한다. SQL Server 2000 그리고 LSF를 이용하였다. 그리고 구현 환경과 구성요소에 대한 수행 화면을 보였다.ool)을 사용하더라도 단순 다중 쓰레드 모델보다 더 많은 수의 클라이언트를 수용할 수 있는 장점이 있다. 이러한 결과를 바탕으로 본 연구팀에서 수행중인 MoIM-Messge서버의 네트워크 모듈로 다중 쓰레드 소켓폴링 모델을 적용하였다.n rate compared with conventional face recognition algorithms. 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임

  • PDF

Analysis of inner parts in the disc cutters applied to the field tests (현장적용 디스크커터의 내부부품 분석)

  • Bae, Gyu-Jin;Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Song, Bong-Chan;Kim, Kab-Boo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.4
    • /
    • pp.473-485
    • /
    • 2015
  • The problems for non-rotating of a disc cutter proceed from the faults in inner parts of the disc cutter such as the leak of hydraulic fluid, the intrusion of tunnel mucks and water, overloading, overheating, poor assembly and substandard material. The rotating of a disc cutter is an indicator to show that the inner parts of disc cutter is operable, although the rotational torque depends on the extent of the damage. Therefore, the key in the problems for non-rotating of disc cutter is to maintain that the tapered roller bearings are working properly. This study aims to investigate the inner parts disassembled from disc cutters applied to the field tests in order to help decision for reuse of the disc cutters. As results, surface finishing to remove the scratch on the load zone of the hubs is needed, with the intent to reuse a hub. And the investigation of lapping surface by optical microscope of floating seals and the contamination test of oil need to be performed for reuse of a disc cutter. Especially, the analysis results show that the floating seals play a key role in the normal operation of bearings. There is nothing significant to report in the rest parts such as bearing, shaft, seal retainers.

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.

Implementation of an operation module for an integrated network management system of ship-based and offshore plants (해양플랜트 및 선박의 네트워크 통합 관리 시스템 운용 모듈 개발)

  • Kang, Nam-Seon;Lee, Seon-Ho;Lee, Beom-Seok;Kim, Yong-Dae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.613-621
    • /
    • 2016
  • This research connected network equipment, including CCTV, PAGA, IP-PBX, and Legacy, in order to enable the operation and configuration of internal IP-based network equipment in maritime plants and vessels, both in the field and from remote places, and to allow for the support of remotely controlling such equipment. It also realized an operating program for the integrated network equipment management system to enable the monitoring and control of equipment status, operation condition, and notifications from distant places. By applying the operating program to satellite stations and vessels sailing on the sea, a performance test was conducted to evaluate data loss and transmission/reception delay in the communication section between the land and vessels. As a result, this research verified the normal operation of CCTV control and of real-time monitoring and control of the network equipment, including PAGA, IP-PBX, and Legacy under the FBB and MVSAT environments. It was observed that the transmission of CCTV video images with a large volume of data as well as the transmission and reception of voice data were found to be slightly delayed, indicating the need to develop technology to compress and convert data for real-time transmission and reception.

The Optimization of Hybrid BCI Systems based on Blind Source Separation in Single Channel (단일 채널에서 블라인드 음원분리를 통한 하이브리드 BCI시스템 최적화)

  • Yang, Da-Lin;Nguyen, Trung-Hau;Kim, Jong-Jin;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.1
    • /
    • pp.7-13
    • /
    • 2018
  • In the current study, we proposed an optimized brain-computer interface (BCI) which employed blind source separation (BBS) approach to remove noises. Thus motor imagery (MI) signal and steady state visual evoked potential (SSVEP) signal were easily to be detected due to enhancement in signal-to-noise ratio (SNR). Moreover, a combination between MI and SSVEP which is typically can increase the number of commands being generated in the current BCI. To reduce the computational time as well as to bring the BCI closer to real-world applications, the current system utilizes a single-channel EEG signal. In addition, a convolutional neural network (CNN) was used as the multi-class classification model. We evaluated the performance in term of accuracy between a non-BBS+BCI and BBS+BCI. Results show that the accuracy of the BBS+BCI is achieved $16.15{\pm}5.12%$ higher than that in the non-BBS+BCI by using BBS than non-used on. Overall, the proposed BCI system demonstrate a feasibility to be applied for multi-dimensional control applications with a comparable accuracy.

Development of Fog Cooling Control System and Cooling Effect in Greenhouse (온실 포그 냉방 제어시스템 개발 및 냉방효과)

  • Park, Seok Ho;Moon, Jong Pil;Kim, Jin Koo;Kim, Seoung Hee
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.265-276
    • /
    • 2020
  • This study was conducted to provide a basis for raising farm income by increasing the yield and extending the cultivation period by creating an environment where crops can be cultivated normally during high temperatures in summer. The maximum cooling load of the multi-span greenhouse with a floor area of 504 ㎡ was found to be 462,609 W, and keeping the greenhouse under 32℃ without shading the greenhouse at a high temperature, it was necessary to fog spray 471.6 L of water per hour. The automatic fog cooling control device was developed to effectively control the fog device, the flow fan, and the light blocking device constituting the fog cooling system. The fog cooling system showed that the temperature of the greenhouse could be lowered by 6℃ than the outside temperature. The relative humidity of the fog-cooled greenhouse was 40-80% during the day, about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The relative humidity of the fog cooling greenhouse during the day was 40-80%, which was about 20% higher than that of the control greenhouse, and this increase in relative humidity contributed to the growth of cucumbers. The yield of cucumbers in the fog-cooled greenhouse was 1.8 times higher in the single-span greenhouse and two times higher in the multi-span greenhouse compared to the control greenhouse.

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Highly Reliable Fault Detection and Classification Algorithm for Induction Motors (유도전동기를 위한 고 신뢰성 고장 검출 및 분류 알고리즘 연구)

  • Hwang, Chul-Hee;Kang, Myeong-Su;Jung, Yong-Bum;Kim, Jong-Myon
    • The KIPS Transactions:PartB
    • /
    • v.18B no.3
    • /
    • pp.147-156
    • /
    • 2011
  • This paper proposes a 3-stage (preprocessing, feature extraction, and classification) fault detection and classification algorithm for induction motors. In the first stage, a low-pass filter is used to remove noise components in the fault signal. In the second stage, a discrete cosine transform (DCT) and a statistical method are used to extract features of the fault signal. Finally, a back propagation neural network (BPNN) method is applied to classify the fault signal. To evaluate the performance of the proposed algorithm, we used one second long normal/abnormal vibration signals of an induction motor sampled at 8kHz. Experimental results showed that the proposed algorithm achieves about 100% accuracy in fault classification, and it provides 50% improved accuracy when compared to the existing fault detection algorithm using a cross-covariance method. In a real-world data acquisition environment, unnecessary noise components are usually included to the real signal. Thus, we conducted an additional simulation to evaluate how well the proposed algorithm classifies the fault signals in a circumstance where a white Gaussian noise is inserted into the fault signals. The simulation results showed that the proposed algorithm achieves over 98% accuracy in fault classification. Moreover, we developed a testbed system including a TI's DSP (digital signal processor) to implement and verify the functionality of the proposed algorithm.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.