THE EFFECTS OF SALIVARY CONTAMINATION OF ACID-ETCHED ENAMEL ON BRACKET BOND STRENGTH (산부식 후 타액오염이 교정용 접착제의 결합강도에 미치는 영향)

  • Kim, Hyun-Deog;Kim, Jong-Sung;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.309-316
    • /
    • 1996
  • The purpose of this study was to determine the effect of salivary contamination of etched enamel on shear bond strength of a bracket adhered to etched enamel. Eighty extracted human permanent premolars were used in this study. These samples were divided into two groups. Buccal surface of samples were etched in vitro with 38% phosphoric acid for 15 seconds and 60 seconds. Each group was divided into four subgroups. Etched enamel surfaces were contaminated with saliva for 0, 1, 20, 60 seconds, washed and dried. Test surfaces were examined using scanning electron microscope(SEM). The shear bond strength of each sample was determined with a universal testing instrument(Instron Co. Model 4201). Results were as follows; 1. Salivary contamination for 1, 20, 60 seconds did not affect shear bond strength when compared with the uncontaminated enamel group. 2 There was no significant difference(P>.05) in shear bond strength between 15 sec. and 60 sec. etching in uncontaminated enamel groups. 3. When samples were examined using SEM, organic materials coated enamel surface masked the etched pattern partially.

  • PDF

Effect of Plant Growth Regulators on Flowering and Micropropagation of Gentiana scabra Bunge In Vitro. (용담의 기내 개화 및 증식에 관한 연구)

  • Son, Beung-Gu;Choi, Young-Whan;Ahn, Chong-Kil;Cho, Dong;Kwon, Oh-Chang;Park, Jung-Ki
    • Journal of Life Science
    • /
    • v.6 no.1
    • /
    • pp.40-47
    • /
    • 1996
  • Experiments were conducted to determine the effects of plant growth regulators on in vitro flowering and micropropagation of Gentiana scabra Bunge which had been used the cut flower, pot flower ornamental and medicinal plants. Flower bud formation was affected by GA$_{3}$ and kinetin. The optimum concentrations for flower bud formation was observed at 0.5 mg/l kinetin and GA$_{3}$ , while kinetin was favorable. More flowerings result from the interaction of GA$_{3}$ and kinetin at in a combination of 0.1 mg/l kinetin + o.1 mg/l GA$_{3}$, but the optimum concentration of GA$_{3}$ and kinetin was decreased. All concentrations of kinetin with 0.1 mg/l GA$_{3}$ or O mg/l GA$_{3}$ + 0.5 mg/l kientin reduced t (weeks needed for 50% plantlets). The plantlet growth was affected by GA$_{3}$ and kinetin during plantlet culture. More lateral shots and better shoot length per plantlet were obtained as GA$_{3}$ and kinetin concentration were increased up to 1.0 mg/l. The number of per plantlet was greater increased in MS medium containing GA$_{3}$ than kinetin. Interaction was exhibited at lower concentration with 0.5mg/l GA$_{3}$ and kinetin, but not in higher concentration with 1.0 mg/l GA$_{3}$ and kinetin. Higher pod diameter increased seed germination, while lower pod diameter was obtained from abnormal plantlet. MA medium containing 0.5 mg/l GA$_{3}$ significantly increased germination without regard to pod diameter.

  • PDF

Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator (의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.109-113
    • /
    • 2002
  • In recent years, the radiotherapy equipment has become much more sophisticated, and with the complication comes an increased set of quality assurance (QA) responsibilities. Today's computer controlled linear accelerator requiring QA of not only the radiation integrity, but also the mechanical accuracy of the linear accelerator. The existing QA sheets are adequate for acceptance testing and commissioning but those sheets are somewhat descriptive form for routine QA. establishing the QA sheets for a facility are more efficient if the sheets could estimate the long-term stability for the result of QA. We are going to develope new prototype of mechanical QA sheet to visualize and to verify long-term stability of mechanical QA for clinical linear accelerator. The items included in mechanical QA sheet were 1) gantry rotation, 2) collimator rotation, 3) couch rotation, 4) optical distance indicator (ODI), and 5) laser alignment. We compared new prototype sheet with conventional sheet for several hospitals in Korea for those items. The QA acceptance criteria in this study mainly followed published recommendations. The contents of test for mechanical QA are the following. Confirm that the digital and/or mechanical gantry angle readouts are correct. Verify that digital and/or mechanical readouts of collimator angle agree with the true angle, as determined with the protractor. Measure the light field using a graph paper and compare with the digital readouts. Confirm digital readout accuracy. Verify that the sagittal laser, the left and right lasers, and the ceiling laser intersect at the isocenter. In the design of new QA sheet, we emphasized the representation of the long-term stability of mechanical QA by using Excel program. By using the new prototype QA sheet, we simplified and visualized the mechanical QA process, and could estimate the long-term stability of mechanical error of linear accelerator.

  • PDF

Sanitizing Agent Effect and Antibiotic Resistance of Salmonella spp. Isolated from Raw Chicken Carcasses in Food Service (집단급식용 생계육에서 분리된 Salmonella의 항생체 내성과 위생 처리제의 영향)

  • Kang, Ji-Hyun;Lee, Young-Duck;Jung, Ki-Chang;Park, Jong-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.582-588
    • /
    • 2001
  • To control the growth of Salmonella on raw chicken supplied in food service, they were isolated and analysed for their physiological characteristics. Total viable microbe counts under the skin of the chicken amounted to 10% of numbers on their skin. Fifty one of Salmonella were isolated and identified from 75 chicken carcass samples. About 70% of the isolates showed resistance to more than four antibiotics, which indicated very high resistance among the strains ever reported in Korea. Lactic acid and trisodium phosphate(TSP) as sanitizing agent were applied to the Salmonella spp. isolates by agar diffusion method. The resistance by isolates to those sanitizing agents was compared with type strains of S. typhimurium ATCC 14028, S. typhimurium ATCC 12023, S. heidelberg and S. enteritidis. The isolates showed similar or less resistance to the type strains as for the lactic acid. However, as for trisodium phosphate known recently as a good sanitizer, 50% of the isolates showed more resistant compared with the type strains. Also, the treatment time and regeneration medium affected significantly the resistance of the isolates, which indicates that more careful test might be needed for TSP's practical application to raw chicken. Therefore, From the results, it is suggested that antibiotic treatment during breeding broiler and contamination after slaughtering should be minimized along with careful use of sanitizing agent in order to ensure more safe raw chicken supply.

  • PDF

Effects of Different Coir Tapes as Plant Mat on the Growth in Dendranthema grandiflorum 'White Miri' (코아 식생매트가 국화 'White Miri'의 생육에 미치는 영향)

  • Nam, Yukyeong;Lee, Jin-Hee;Jeong, Gi-Ryeong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.4
    • /
    • pp.192-196
    • /
    • 2011
  • This study was conducted to develop the suitable plant mat for garden mum. The results about growth 2 months after cutting of garden mum (Dendranthema grandiflorum 'White Miri') under 6 different plant-mat treatments using coir tape were as follows. The majorities of cuttings were withered under treatments of non-soiled 15 mm thick mat (C treatment). On the other hand, the same thick mat having a hole filled with soil 3 mm in diameter (D treatment) and the 30 mm thick mat having a hole filled with soil (F treatment) showed the best growth results. The survival rates of treatments D and F showed the higher rates of 100 and 90%, respectively than those of respective 56.3 and 20% of two layers without medium (A treatments) and C treatment having respective 10 and 15 mm thick non-soiled mats. The plant height showing the similar tendency with the result of the survival rate was shown with the lower value of 7.97 and 7.15 cm, respectively under treatments A and C, compared with the higher value of 9.74 and 9.80 cm respectively under treatments D and F. For flower gardening, it is better to adopt treatment D based on the our investigational results that treatment D required less soil than treatment F and had no trouble with forming adventitious roots for manufacturing mats and effective transferring.

Research on Real-time Flow Rate Measurement and Flood Forecast System Based on Radar Sensors (레이다 센서 기반 실시간 유량 측정 및 홍수 예측 시스템 연구)

  • Lee, Young-Woo;Seok, Hyuk-Jun;Jung, Kee-Heon;Na, Kuk-Jin;Lee, Seung-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.288-290
    • /
    • 2022
  • As part of the SOC digitization for smart water management and flood prevention, the government reported that automatic and remote control system for drainage facilities (180 billion won) to 57% of national rivers and established a real-time monitoring system (30 billion won). In addition, they were also planning to establish a smart dam safety management system (15 billion won) based on big data at 11 regions. Therefore, research is needed for smart water management and flood prevention system that can accurately calculate the flow rate through real-time flow rate measurement of rivers. In particular, the most important thing to improve the system implementation and accuracy is to ensure the accuracy of real-time flow rate measurements. To this end, radar sensors for measuring the flow rate of electromagnetic waves in the United States and Europe have been introduced and applied to the system in Korea, but demand for improvement of the system continues due to high price range and performance. Consequently, we would like to propose an improved flow rate measurement and flood forecast system by developing a radar sensor for measuring the electromagnetic surface current meter for real-time flow rate measurement.

  • PDF

The Efficacy of Added Montelukast in Persistent Asthmatics Who Were Not Completely Controlled on Inhaled Corticosteroids and Inhaled Long-acting β2-agonists (흡입 스테로이드와 지속성 베타2 항진제의 병용요법으로 완전히 조절되지 않는 천식 환자에서 추가 montelukast의 효과)

  • Choi, Jeong-Hee;Park, Hae-Sim;Lee, Kwan-Ho;Shim, Jae-Jeong;Uh, Soo-Taek;Lee, Sang-Pyo;Lee, Yong-Chul;Choi, Won-Il;Lee, Jae-Ho;Kim, Joo-In;Lee, Myung-Goo;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.4
    • /
    • pp.337-345
    • /
    • 2007
  • Backgrounds: Although glucocorticoids are one of the most potent anti-inflammatory agents, they have limited effect on cysteinyl leukotriene biosynthesis. In addition, the response to inhaled corticosteroids (ICS) and inhaled long-acting ${\beta}_2-agonists$ (LABA) combination therapy in moderate to severe persistent asthmatics varies. Additional therapy with leukotriene receptor antagonists (LTRA) in patients with moderate to severe asthma suboptimally controlled with ICS and LABA combination therapy would be complementary to asthma control. Methods: One hundred and ninety eight asthmatics entered a 2 month, open-label descriptive study. Patients suffering from persistent asthma and suboptimally controlled on a combination therapy of fluticasone/salmeterol or budesonide/formoterol were given montelukast 10 mg daily as an add-on therapy. The level of asthma control was assessed using the Asthma Control Questionnaire (ACQ) including $FEV_1%$ predicted at the baseline and after a 2-month treatment with montelukast. A global evaluation of the treatment was also made by the patients and physicians. Results: The mean ACQ score decreased significantly on montelukast ($11.5{\pm}5.4$ at baseline vs. $6.7{\pm}5.0$), with a significant improvement in all individual symptom scores (p<0.01). The $FEV_1%$ predicted values did not show any significant change. 59.9% of patients and 59.4% of physicians reported global improvement in their asthma (${\kappa}=0.85$). Conclusion: These results suggest that the addition of montelukast in patients with persistent asthma that is suboptimally contolled by combination therapy of ICS and LABA might confer complementary effects on asthma control.

Shear bond strength of metal orthodontic brackets bonded with Self-Etching Primer (Self-etching primer를 이용하여 접착된 교정용 브라켓의 전단결합강도)

  • Ahn, Yun-Pyo;Kim, Hyo-Young;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.51-61
    • /
    • 2003
  • The purpose of this study was to evaluate the effects of a self-etching primer on the shear bond strength of orthodontic brackets and on the failure pattern of bracket-adhesive interfaces in dry or wet condition. Brackets were bonded to extracted human teeth according to one of three experimental protocols. In the Group P, teeth were etched with $37\%$ phosphoric acid. After the Transbond XT Primer was applied onto the etched surfaces, the brackets were bonded with Transbond XT(3M, Unitek, Monrovia, Calif) and light cured for 40 seconds. In the Group SD, a self-etching primer(3M, Unitek, Monrovia, Calif) was placed on the enamel for 3 seconds and gently evaporated with air, as suggested by the manufacturer. The brackets were then bonded with Transbond XT as in the Group P In the Group SW, artificial saliva was applied to the enamel surface for 10 seconds to allow complete hydration of the surface before application self-etching primer The brackets were then bonded following the procedures of Group SD. Each group was divided into 2 sub-groups(0.5h, 24h) according to debonding time. Shear bond strengths were measured by Instron universal testing machine. After debonding, the teeth and brackets were examined under scanning electron microscope and assessed with the adhesive remnant index. The result obtained were summarized as follows ; 1. The shear bond strengths were high enough to use clinically in all testing groups, but the shear bond strengths of Group SD and SW were significantly lower than Group P(p<0.05). 2. With respect to comparison of debonding time, 24h debonding samples exhibited heigher shear bond strength than 0.5h debonding samples in Group P, SD and SW(p<0.05). 3. In the self etching primer groups(Group SD and Group SW), there was no significant difference in mean shear bond strength between under dry and wet state(p>0.05). 4. There was a greater frequency of ARI score of 0 and 1 with the Group P. On the other hand, there was a higher frequency of ARI scores of 2 and 3 with Group SD and Group SW(p<0.05).

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.