• Title/Summary/Keyword: 정격 출력

Search Result 226, Processing Time 0.023 seconds

Pitch Angle Controller of Wind Turbine System Using Neural Network (신경망을 이용한 풍력 발전시스템의 피치제어)

  • Hong, Min-Ho;Ko, Seung-Youn;Kim, Ho-Chan;Hur, Jong-Chul;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1059-1065
    • /
    • 2014
  • Wind turbine system can obtain the maximum wind energy using torque control under the rated wind speed, and wind turbine power is controlled as the rated power using pitch control over the rated wind speed. In this paper, we present a method for wind turbine pitch controller using neural networks. The purpose of the pitch control is to control generator speed and power in the above rated wind speed. To improve the neural network pitch controller, the difference between a rated and current speed of generator has been used for another input of neural networks as well as wind speed. Error back-propagation algorithm is used for training the neural network pitch controller and simulation and Matlab/Simulink is used for verifying that this system is controlled well.

A Study on the Performance Estimation and Shape Design of a Counter-Rotating Tidal Current Turbine (상반전 조류발전 터빈의 형상설계 및 성능예측에 관한 연구)

  • Kim, Mun-Oh;Kim, You-Taek;Lee, Young-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.586-592
    • /
    • 2014
  • This study looks at the design of a 100 kW blade geometry for a horizontal marine current turbine using the Blade Element Momentum Theory (BEMT) and by using (CFD), the power output, performance and characteristics of the the fluid flow over the blade is estimated. Three basic airfoils; FFA-W3-301, DU-93-W210 and NACA-63418, are used along the blade span and The distribution of the chord length and twist angles along the blade are obtained from the hydrodynamic optimization procedure. The power coefficient curve shows maximum peak at the rated tip speed ratio of 5.17, and the maximum power reaches about 101.82 kW at the power coefficient of 0.495.

A Study on the Variable Structure Adaptive Control Systems for a Nuclear Reactor (가변구조 적응제어이론에 의한 원자로부하추종 출력제어에 관한 연구)

  • Sung Ha Kwon;Hee Young Chun;Hyun Kook Shin
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.247-255
    • /
    • 1985
  • This paper describes a new method for the design of variable structure model-following control systems(VSMFC). This design concept is developed using the theory of variable structure systems (VSS) and slide mode. The new results are presented on the sliding control methodology to achieve accurate tracking for a class of nonlinear, multi-input multi-output(MIMO), time varying systems in the presence of parameter variations. The design requires little computational effort. The dynamic response is insensitive to parameter variations. The feasibility and the advantages of the method are illustrated by applying it to a 1000 MWe boiling water reactor(BWR). The control is studied in the range of 85%∼90% of rated power for load-following control. A set of 12 nonlinear differential equations is used to simulate the total plant. A 6-th order linear model has been developed from these equations at 85% of rated power. The obtained controller is shown by simulations to be able to compensate for a plant parameter variation over a wide power range.

  • PDF

Comparison of Characteristics with Output Filter Inductor for Grid-Connected PV Inverter (계통연계형 태양광발전용 인버터의 출력필터 인덕터의 특성 비교)

  • Kim, Seungsik;Min, Joon-ki;Kum, Manhee;Lee, Bong-seob
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.101-102
    • /
    • 2014
  • 본 논문에서는 10kW급 태양광발전용 계통연계형 무변압기 방식 인버터의 출력필터로 사용되는 인덕터의 코어별 3종에 대하여 스위칭 주파수 10kHz에 적합한 출력필터용 인덕터를 선정하고 온도특성 따른 영향을 비교하고자 실험을 통하여 정격시 출력전압 및 출력전류의 값, 왜형율, 역률, 인버터의 전력 변환 효율 및 코어의 철손온도와 권선의 동손온도를 측정하여 정량적으로 비교하였다. 또한, 실험 결과를 참고로 하여 인덕터의 코어뿐만 아니라 권선방식과 인덕턴스를 확보하기 위한 방안도 비교하였다.

  • PDF

Study of the Characteristic and Optimization of Induction Lamp according to Gas Pressure and Amalgam Type (고출력 무전극램프의 가스압 및 아말감종류에 따른 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Kim, Yong-Kab;Park, Dae-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • Currently, road lightings are installed with less than 400W of existing metal halide lamps. These road lightings are being replaced by energy-saving lightings. Induction lamps are expected to be more actively replaced with targets for tunnel lighting and high ceiling lighting. Therefore, it is necessary to develop high efficiency, high power induction lamps system. In this study, the gas type & pressure, amalgam type were designed for the high power of the induction lamps. And induction lamp system was optimized through electrical, optical characteristics analysis. It is optimized to the gas pressure 300~350 [mmHg] for the discharge tube of high power induction lamp and ferrite core. The driving circuit matching was completed with a induction lamp using indium amalgam. The rated power consumption of the induction lamp was optimized with 250 W (rated ${\pm}10%$)

A constant power and optimal power factor drive of doubly fed induction generator (이중여자 유도발전기의 정출력.최적역률 운전)

  • 이우석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.31-38
    • /
    • 2000
  • Wide operating range and speed control is needed for wind power generating and a Doubly Fed Induction Generator(DFIG) has good adaptivity for that purpose. This paper deals with the speed, power, and power factor control using the Grid connected DFIG in the super-synchronous speed regions, by controlling frequency and voltage fed to the rotor. Power flow of the DFIG and steady-state algebraic equations of the equivalent circuit are analyzed. The wind turbine speed and constant stator power were controlled by the rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, rotor exciting frequency. For a normal operating region, in which the generator ratings were not exceeded, the rotor current was either less than or equal to the rated value. Accordingly, the optimal power factor can be selected relative to the permissible rated current at the rotor coil which controls the magnitude of the injected rotor voltage to the rotor according to a given rotor frequency. Consequently, it is possible to determine the optimal drive of a DFIG for wind power generation application.

  • PDF

Tracking Controller Design Using Delayed Output Feedback For Systems With Stiff Nonlinearities (심한 비선형성을 갖는 시스템의 시간지연 출력궤환을 이용한 추종제어기의 설계)

  • 나승유
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.4
    • /
    • pp.342-349
    • /
    • 1991
  • In this paper, a method is presented for designing a tracking and disturbance rejecting controller for a nonlinear control system in which approximate linearization is not applicable due to a s stiff nonlinearity. Only the measurable variables are used for the controller synthesis. The system is augmented by a compensator at the output side for the tracking and disturbance rejection. An output delayed feedback controller is designed for the augmented system without nonlinearity. Then the feedback parameters are adjusted by describing function method to overcome the limit cycle due to the nonlinearity.

  • PDF

Design of High-Power Pulse Transformer for the 80-MW Klystron Load (80-MW 클라이스트론 부하용 대출력 펄스 트랜스포머의 설계)

  • Jang, S.D.;Chung, S.H.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2119-2122
    • /
    • 2000
  • 포항 방사광 가속기의 선형 가속기에서는 80-MW 클라이스트론 부하를 구동하기 위하여 최대 펄스 정격출력 200 MW(400kv 500A, 평탄도 4.4 $\mu s$)인 대출력 펄스 트랜스포머가 요구된다. 펄스 트랜스포머는 펄스 전원공급 장치(Modulator)로부터 대출력 부하(Klystron)로 펄스 에너지를 전달하며 임피던스 정합을 시키는 기능을 한다. 모듈레이터의 고전압 출력 펄스에서 RF 에너지를 발생시키는데 사용되는 유효 출력 에너지는 출력 펄스의 평탄부의 에너지에 해당된다. 그러므로, 펄스 트랜스포머는 빠른 상승시간을 가지는 것이 요구된다. 빠른 상승시간을 얻기 위하여 누설자속, 분포용량이 작게 되도록 설계하여야 한다.

  • PDF

Analysis of Internal Dynamics in Modular Multilevel Converter for Reducing Power Oscillation Under Grid Voltage Distortion (AC 계통 불평형 조건에서 출력동요 저감을 위한 MMC 내부 동적특성 분석)

  • Lee, Sang-Jung;Kang, Jaesik;Kang, Dae-Wook;Park, Young-Joo;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.320-321
    • /
    • 2020
  • 본 논문은 AC 계통 불평형 발생 시 출력전력의 동요를 저감시키기 위한 POD 전략을 수행하는 MMC-HVDC 시스템의 내부 동적상태를 분석하였다. POD 전략을 통해서 MMC 출력전류의 역상분을 제어하여 계통에 주입되는 유효 전력의 발진을 제거함으로써, MMC-HVDC 시스템이 연계된 인근 계통에 공급 신뢰도를 향상시킬 수 있다. POD 전략에서 유효 전력만 출력할 경우, MMC의 각 상에는 동일한 전력이 흐른다. 반면, 계통 전압 보상을 위해서 무효 전력을 동시에 공급할 경우, 각 상에 흐르는 전력은 불균형해지기 때문에 MMC의 암전류 불평형이 발생하여 스위치 소자의 정격 용량 및 열 스트레스를 증가 시켜 MMC의 안정성을 저해시킨다. 본 논문은 POD 전략을 수행하기 위해서 무효 전력이 MMC 암 전류에 미치는 영향을 분석하였으며, 200 MW MMC-HVDC 모델을 바탕으로 PSCAD/EMTDC 시뮬레이션 툴을 이용하여 분석 결과를 검증하였다.

  • PDF

Study on the Small Scale CGS for APT. Complex (아파트 단지를 대상으로 한 소형 열병합 발전 시스템 검토)

  • 박화춘;박병식;정우용
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.221-227
    • /
    • 2000
  • The optimal capacity of CGS(Co-Generation Sys.) for APT. complex is 300kW output of electricity power from being considered the simple payback period, loss and benefit, and the running mode of CGS. The proper operation mode of CGS is as follows; If the demanding electricity load of APT. complex is within the range of capacity of generator(300kW), CGS is connected and operated with KEPCO grid. When the load ratio is over 50% of normal load of CGS(300kW), only CGS supply electricity demand. If not, the electricity line of CGS is exchanged to that of KEPCO.

  • PDF