• Title/Summary/Keyword: 접합면

Search Result 513, Processing Time 0.029 seconds

Electrical Properties of Ultra-shallow$p^+-n$ Junctions using $B_{10}H_{14}$ ion Implantation ($B_{10}H_{14}$ 이온 주입을 통한 ultra-shallow $p^+-n$ junction 형성 및 전기적 특성)

  • 송재훈;김지수;임성일;전기영;최덕균;최원국
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • Fabricated were ultra-shallow $p^+-n$ junctions on n-type Si(100) substrates using decaborane $(B_{10}H_{14})$ ion implantation. Decaborane ions were implanted at the acceleration voltages of 5 kV to 10 kV and at the dosages of $1\times10^{12}\textrm{cm}^2$.The implanted specimens were annealed at $800^{\circ}C$, $900^{\circ}C$ and $1000^{\circ}C$ for 10 s in $N_2$ atmosphere through a rapid thermal process. From the measurement of the implantation-induced damages through $2MeV^4 He^{2+}$ channeling spectra, the implanted specimen at the acceleration voltage of 15 kV showed higher backscattering yield than those of the bare n-type Si wafer and the implanted specimens at 5 kV and 10 kV. From the channeling spectra, the calculated thicknesses of amorphous layers induced by the ioin implantation at the acceleration voltages of 5 kV, 10 kV and 15 kV were 1.9 nm, 2.5 nm and 4.3 nm, respectively. After annealing at $800^{\circ}C$ for 10 s in $N_2$ atmosphere, most implantation-induced damages of the specimens implanted at the acceleration voltage of 10 kV were recovered and they exhibited the same channeling yield as the bare Si wafer. In this case, the calculated thickness of the amorphous layer was 0.98 nm. Hall measurements and sheet resistance measurements showed that the dopant activation increased with implantation energy, ion dosage and annealing temperature. From the current-voltage measurement, it is observed that leakage current density is decreased with the increase of annealing temperature and implantation energy.

Evaluation of Gamma Irradiation for Extending the Shelf Life of Kimchi (김치의 저장성 연장을 위한 Gamma선 조사)

  • Cha, Bo-Sook;Kim, Woo-Jung;Byun, Myung-Woo;Kwon, Joong-Ho;Cho, Han-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.109-119
    • /
    • 1989
  • To improve the storage method of Kimchi, optimum ripening Kimchi for an irradiation treatment(the time of around 0.3% in total acidity of Kimchi) was irradiated by doses of 1, 2, 3 kGy with Co-60 ${\gamma}-radiation$ and stored at $10^{\circ}C$. Total aerobic bacteria increased in the beginning of storage and then decrease slowly as the number of total lactic acid bacteria increased. Total lactic acid bacteria initially loaded by $10^8\;cells/ml$ in Kimchi shortly after irradiation reduced to $10^4-10^6\;cells/ml$ with 1-3 kGy doses and decreased gradually through the whole storage period. The initial load of yeast, $10^3\;cells/ml$, increased steadily during Kimchi storage and led to more than $10^4\;cells/ml$ after 30 days of storage. While it maintained tha the load in 2-3 kGy irradiated groups after 30 days of storage was less than that at the beginning of storage. pH, acidity and volatile acid in the nonirradiated group were 4.0, 0.7% and 0.06%, respectively at the 15th day after storage, but at the 30th day after storage, 2-3 kGy irradiated groups showed different values, 4.1, 0.58-0.63%, and 0.04-0.05%, respectively. The texture(firmness) of Kimchi reduced along with storage time, and 2 kGy irradiated group proved most favourable in its texture during storage. In the sensory evaluation of Kimchi, nonirradiated group was inedible after 15 days of storage, whereas 2-3 kGy irradiated groups could proling the storage-life of Kimchi over 2 times compared with the nonirradiated Kimchi, showing the good sensory quality even after 30 days of storage.

  • PDF

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

The Effects of Thermal Degradation and Creep Damage on the Microstructure and Composition of the Carbides in the CrMo Steels for Power Plant (발전 설비용 CrMo강의 탄화물 구조와 조성 변화에 미치는 열화 및 크리프 손상의 영향)

  • Ju, Yeon-Jun;Hong, Gyeong-Tae;Lee, Hyeon-Ung;Sin, Dong-Hyeok;Kim, Je-Won
    • Korean Journal of Materials Research
    • /
    • v.9 no.10
    • /
    • pp.1018-1024
    • /
    • 1999
  • The effects of operating temperature and stress on degradation of components in high temperature steam generator were investigated. Several 2.25CrlMo tubes which had operated over 20 years and an unused 9CrlMoVNb tube were tested. For the former samples, the amount of $\textrm{M}_{6}\textrm{C}$ carbide and its size are increased with the aging or operating time. The precipitation behavior of carbides ($\textrm{M}_{2}\textrm{O}$, $\textrm{M}_{6}\textrm{C}$) is changed with the operating temperature of the tubes. However, unused 9CrlMoVNb samples show a different carbide precipitation process due to high chromium, vanadium, and niobium contents. The amount of Cr-rich $\textrm{M}_{23}\textrm{C}_{6}$ carbide is significantly increased with aging time, but that of $\textrm{M}_{6}\textrm{C}$ type carbide is rarely changed with aging time at elevated temperatures.

  • PDF

Development of head loss coefficient formula at surcharged four-way combining square manhole with variation of inlet flow (유입유량 변화를 고려한 과부하 4방향 사각형 합류맨홀에서의 손실계수 산정식 개발)

  • Jo, Jun Beom;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.877-887
    • /
    • 2017
  • The energy losses due to surcharged flow at four-way combining manhole, which is mainly installed in the downstream of urban sewer system, is the main cause of inundation in urban area. Surcharged four-way combining manholes form various flow configuration such as straight through, T-type, and four-way manholes depending on variation of inflow discharge in inlet pipes. Therefore, it is necessary to analyze change of energy loss and estimate head loss coefficients at surcharged four-way combining manhole with variation of inflow discharge ratio. The hydraulic experimental apparatus which can change inflow ratios were installed to analyze the flow characteristics at four-way combining manhole. In this study, to calculate the head loss coefficient according to change of the inflow discharge ratios at the surcharged four-way combining square manhole, the discharge conditions of 40 cases which the inflow ratios of each inlet pipe were changed by 10% interval was selected. The head loss coefficient at surcharged square manhole showed the lowest value of 0.40 at the straight manhole and the highest value of 1.58 at the $90^{\circ}$ junction manhole. In the combining manholes (T-type and four-way), the head loss coefficients were calculated more higher as the lateral flow rate was biased. The contour map of head loss coefficient range was constructed by using the estimated head loss coefficients and the empirical formula of head loss coefficients was derived to consider the variation of inflow discharge ratios at the surcharged square manhole. The empirical formula could be applied to the design and assessment of the urban drainage system.

Half-metallicity and Magnetism of Co2ZrSi/ZnTe(001) Interface: A First-principles Study (Co2ZrSi/ZnTe(001)계면의 자성과 반쪽금속성에 대한 제일원리 연구)

  • Jin, Y.J.;Lee, J.I.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.147-151
    • /
    • 2007
  • We have investigated the half-metallicity and magnetism for the Heusler ferromagnet $Co_2$ZrSi interfaced with semiconductor ZnTe along the (001) plane by using the full-potential linearized augmented plane wave (FLAPW) method. We considered low types of possible interfaces: ZrSi/Zn, ZrSi/Te, Co/Zn, and Co/Te, respectively. From the calculated density of states, it was found that the half-metallicity was lost at all the interfaces, however for the Co/Te system the value of minority spin density of states was close to zero at the Fermi level. These facts are due to the interface states, appeared in the minority spin gap in bulk $Co_2$ZrSi, caused by the changes of the coordination and symmetry and the hybridizations between the interface atoms. At the Co/Te interface, the magnetic moments of Co atoms are 0.68 and $0.78{\mu}_B$ for the "bridge" and "antibridge" sites, respectively, which are much reduced with respect to that ($1.15{\mu}_B$) of the bulk $Co_2$ZrSi. In the case of Co/Zn, Co atoms at the "bridge" and "antibridge" sites have magnetic moments of 1.16 and $0.93{\mu}_B$, respectively, which are almost same or slightly decreased compared to that of the bulk $Co_2$ZrSi. On the other hand, for the ZrSi/Zn and ZrSi/Te systems, the magnetic moments of Co atoms at the sub-interface layers are in the range of $1.13{\sim}1.30\;{\mu}_B$, which are almost same or slightly increased than that of the bulk $Co_2$ZrSi.

Characteristics of LSC coated Metallic Interconnect for Solid Oxide Fuel Cell (LSC가 코팅된 고체산화물 연료전지용 금속연결재의 특성 연구)

  • Pyo, Seong-Soo;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • This study reports the high-temperature oxidation kinetics, ASR(area specific resistance), and interfacial microstructure of metallic interconnects coated with conductive oxides in oxidation atmosphere at $800^{\circ}C$, The conductive material LSC($La_{0.8}Sr_{0.2}CoO_3$, prepared by Solid State Reaction) was coated on the Crofer22APU. The contact behavior of coating layer/metal substrate was increased by sandblast. The electrical conductivity of the LSC coated Crpfer22APU was measured by a DC two probe four wire method for 4000hr, in air at $800^{\circ}C$. Microstructure and composition of the coated layer interface were investigated by SEM/EDS. These results show that a coated LSC layer prevents the formation and growth of oxide scale such as $Cr_2O_3$ and enhances the long-term stability and electrical performance of metallic interconnects for SOFCs.

Fabrication and Characteristics of High Efficiency Silicon PERL (passivated emitter and rear locally-diffused cell) Solar Cells (PERL (passivated emitter and rear locally-diffused cell) 방식을 이용한 고효율 Si 태양전지의 제작 및 특성)

  • Kwon, Oh-Joon;Jeoung, Hun;Nam, Ki-Hong;Kim, Yeung-Woo;Bae, Seung-Chun;Park, Sung-Keoun;Kwon, Sung-Yeol;Kim, Woo-Hyun;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • The $n^+/p/p^+$ junction PERL solar cell of $0.1{\sim}2{\Omega}{\cdot}cm$ (100) p type silicon wafer was fabricated through the following steps; that is, wafer cutting, inverted pyramidally textured surfaces etching by KOH, phosphorus and boron diffusion, anti-reflection coating, grid formation and contact annealing. At this time, the optical characteristics of device surface and the efficiency of doping concentration for resistivity were investigated. And diffusion depth and doping concentration for n+ doping were simulated by silvaco program. Then their results were compared with measured results. Under the illumination of AM (air mass)1.5, $100\;mW/cm^2$ $I_{sc}$, $V_{oc}$, fill factor and the conversion efficiency were 43mA, 0.6 V, 0.62. and 16% respectively.

  • PDF

Bearing Strength of Steel Baseplate under Eccentric Loads (편심축력(偏心軸力)을 받는 철골구조(鐵骨構造) 주각부(柱脚部)의 지압강도(支壓强度))

  • Choi, Mun Sik;Min, Byung Yeol
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.683-691
    • /
    • 2003
  • Recently, the steel has been increaseingly used as an integrated part of high-rise buildings, which often composed of steel structures, steel reinforced concrete structures and composite structures. The steel base is designed to transfer the stresses induced from steel column to the reinforced concrete footing through the base plate. However, in the design of steel structures and steel reinforced concrete structure, it is generally difficult to evaluate the bearing strength of the steel base subjected to large axial force. Furthermore, the material used in steel base is quite different from those used in other connections and a load transferring mechanism of steel base is very complicated in nature. Therefore, a special attention must be placed in design and construction of steel base. In generally, the bearing strength test and research of the steel base subjected to concentrated load are carried out. But, in the design of the structures, uniaxial eccentric load is loaded to the steel base of the steel structures. In this research, the bearing strength and the me of failure considering eccentric loads and eccentric length, were experimented when eccentric load is loaded to the steel base of steel structures. Based on the test results, a basic design reference is suggested for a reasonable design of steel structures, steel reinforced concrete structures and composite structures.

Suggestion of Reasonable Analysis Model for Steel Transmission Tower Based on KEPCO Design Specifications (송전철탑 설계기준을 반영한 345kV급 송전철탑의 합리적인 구조해석모델 제안)

  • Chang, Jin Won;Kim, Seung Jun;Park, Jong Sup;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.367-381
    • /
    • 2007
  • A transmission tower was designed using the structural methodology to assume a simple truss behavior. However, there is a big difference between a simple truss behavior and a real one. A suitable explanation of structural stability is that it is a semi-rigid connection and not the assumed hinged connection. This study proposes an alternative structural-analysis modeling strategy for the transmission tower design. The element models that were considered were the truss element model, the beam element model, and the combined beam-truss element model. This study includes linear static analysis, free-vibration analysis, and elastic buckling analysis with respect to the design load. The results of the analysis indicate that the axial forces, axial stresses, and maximum displacements of the three analytical models are very similar. However, the bending moments and stresses of the beam element model and of the combined beam-truss element model are significantly high. The results of the free-vibration and elastic buckling analyses show that the beam-truss model can be conservatively used for the transmission tower design.