• Title/Summary/Keyword: 접촉길이

Search Result 265, Processing Time 0.036 seconds

Antidoting Effect of 1,8-Naphthalic Anhydride on Butachlor Phytotoxicity in Rice (벼에 있어서 Butachlor 약해(藥害)에 미치는 1, 8-Naphthalic Anhydride 의 약해경감효과(藥害輕減效果))

  • Chun, J.C.;Hwang, I.T.;Han, M.S.
    • Korean Journal of Weed Science
    • /
    • v.5 no.2
    • /
    • pp.169-174
    • /
    • 1985
  • Antidoting effect of 1,8-naphthalic anhydride (NA) on butachlor [2-chloro-2', 6'-diethyl-N-(butoxyethyl) acetanilide] phytotoxicity in rice was determined at different seeding depths and application rates of butachlor. The most sensitive response to NA was found in mesocotyl of rice (Oryza saliva L.). The mesocotyl length decreased with use of NA when seeded 2 to 4 cm deep, whereas no effect was obtained in plant height, root length and coleoptile length. Phytotoxic effect of butachlor to rice sown in vermiculite saturated with butachlor solutions decreased with use of NA at all seeding depths employed. However, depth protection was not observed when planted 3 to 4 cm deep without use of NA. Use of NA resulted in reduction in the phytotoxicity at concentrations of butachlor lower than 40 ppmw. The results indicated that the antidoting effect of NA was not due to reduction of mesocotyl elongation which would result in decrease in butachlor uptake through the mesocotyl.

  • PDF

An Experimental Study on Shear and Rotation Stiffness in the Connection Parts of Shores (동바리 연결부의 전단 및 회전 강성 실험)

  • Kwk, Soon-Seop;Kim, Ho-Soo;Jung, Sung-Jin;Hong, Geon-Ho;Lee, Kyoung-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.848-855
    • /
    • 2003
  • During concrete placement, the partially distributed load due to the concrete placement paths creates the lateral force in the connection parts of the shore. In order to restrain this lateral force, the nails must be used in the upper and lower connection parts of shores. But, for the convenience of the construction and dismantling of the shores, the workers hardly use the nails. In this case, the connections of shore cannot resist the shear force and rotation. And this situation may cause the collapse of form-shore system. Therefore, contact and spring models for the connection analysis of the form-shore systems are required. If we take into account this construction situation, we need to understand the effects of shear and rotation stiffness according to the several types of connection parts in shores as a case study. This study evaluates the shear and rotation stiffness of the connection parts of shores according to the variations of the lengths, numbers and positions of nails, and then presents the experimental results depending on the end conditions of shores. And, these results can be used as a spring model and critical load evaluation data for the connection analysis of form-shore system.

A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH (연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석)

  • Jeong, Hoe-Yeol;Choi, Min-Ho;Kim, Yu-Lee;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

EFFECTS OF POLYPHOSPHATE MIXED IN ACRYLIC RESIN ON THE ATTACHMENT AND GROWTH OF ORAL BACTERIA (Acrylic Resin에 혼합된 Polyphosphate가 미생물의 부착 및 성장에 미치는 영향)

  • Hong, Sun-Hee;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.69-79
    • /
    • 2003
  • The purpose of this present study was to develop a new way of self-curing acrylic resin, using commercially available polyphosphate, Calgon, which is known to be antimicrobial and safe. For the study, polyphosphate(polyP) was blended with acrylic powder and devided into four groups as follows: no polyP(control), 1% polyP, 2% polyP, and 3% polyP. For the experiment, Streptococcus mutans GS5, Streptococcus sobrinus 6715, Streptococcus gordonii G9B and Challis, Porphyromonas gingivalis 2561, and Candida albicans ATCC 90027 were used. Resin specimens in each group were tested in vitro for the purpose of investigating the effect of polyP on the microbial attachment, growth and hydrophobicity of the resin surface. The results were as follows. 1. PolyP added to the acrylic resin decreased attachment of S. mutans GS5, S. sobrinus 6715, S. gordonii G9B. The greater binding inhibition was found in acrylic resin polymerized with polyP at higher concentrations. 2. The addition of polyP to acrylic resin failed to significantly affect the growth of the tested microorganisms. 3. The addition of polyP to acrylic resin seemed to reduce hydrophobicity of the acrylic resin. PolyP in acrylic resin does not seem to exert a direct antibacterial activity, but rather inhibit attachment of oral bacteria, especially mutans streptococci to saliva-coated acrylic resin. The acrylic resin reduces attachment of streptococci may be due to the decreased hydrophobicity caused by polyP added to the resin. PolyP may be included to acrylic resin to inhibit dental caries which often occurs when removable acrylic resin appliance is placed.

  • PDF

APPLICATION OF AN ORAL SCREEN (Oral Screen의 임상 적용에 대한 고찰)

  • Park, So-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.246-250
    • /
    • 2000
  • The oral screen is a functional appliance, suitable for the treatment of developing malocclusion associated with aberrant muscular patterns. The better muscle balance between tongue and the buccinator mechanism can be established, and the reestablishment of normal growth and development can be achieved. The oral screen can be used for the correction of the following conditions : (1) thumbsucking, tongue thrusting and lip biting, (2) mouth breathing, (3) mild distocclusion with premaxillary protrusion, (4) open bites in deciduous and mixed dentition, and (5) incompetent lips. The patient should wear the oral screen every night and also during the day whenever possible. The effects of oral screen can be elevated through lip seal exercise : the lips should be kept in contact all the time to improve the lip seal. In the presented two cases, the patients were considered mouth breathers and to have incompetent lips, and one patient with maxillary incisal protrusion and the other with open bite. They were instructed to wear the oral screen with lip seal exercise. After wearing the appliance for 1 and 2 years respectively, mouth breathing was decreased and lip length and strength were increased, the maxillary incisors were retruded and open bite reduced.

  • PDF

Effects of Sm:Ba:Cu Composition Ratio on the Superconducting Properties of SmBCO Coated Conductor Prepared by using a Composition Gradient Method (SmBCO 초전도 선재 특성에 대한 Sm:Ba:Cu 조성비의 영향)

  • Kim, H.S.;Oh, S.S.;Jang, S.H.;Min, C.H.;Ha, H.S.;Ha, D.W.;Ko, R.K.;Youm, D.J.;Moon, S.H.;Chung, K.C.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.7-11
    • /
    • 2011
  • The effects of Sm:Ba:Cu composition ratio in SmBCO coated conductor on their superconducting properties were investigated. The SmBCO coated conductors were fabricated by reactive co-evaporation method using EDDC(Evaporation using Drum in Dual Chamber) system. In this system, we could obtain various samples with different composition ratios in a batch by the technique providing composition gradient at deposition zone. From the specimens prepared by EDDC system, we found that composition ratio is uniform parallel to the drum axis, but gradient along the circumferential direction of the drum. We installed a shield having parallelogram open area between the deposition chamber and the evaporation chamber in EDDC system, and attached a 30 cm long template, which is parallel to drum axis, onto the drum surface. In this configuration, we could obtain SmBCO coated conductors having a gradient composition along the length of template. We measured the composition ratios and surface morphologies with periodic interval by SEM and EDAX, and confirmed the profile of composition ratio. We also measured critical current using non-contact Hall probe critical current measurement system and thereby could plot composition ratio vs. critical current. The maximum critical current was obtained, and the surface morphology with the shape of roof tile was observed at the corresponding composition ratio of Sm:Ba:Cu = 1.01:1.99:4.87. It was also found that composition ratio had an effect on not only critical current but also surface morphology.

Behavior of Hybrid Stud under Compressive Load (복합스터드의 압축 좌굴 거동)

  • Lee, Sang Sup;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.609-619
    • /
    • 2004
  • An investigation was conducted on the activities around Europe in order to solve the problem of the thermal bridging of steel studs, which had caused a significant disadvantage. This study included the following: diminishing the contact area between the studs and the sheathing, lengthening the heat transfer route, replacing the steel web with a less conductive material, and placing foam insulation in locations where the thermal shorts are most critical. Although energy efficiency is usually the focus of such foreign cases because their stud application is mostly limited to low-rise residential buildings, both structural and thermal performance are taken into consideration in this study because these target middle-story buildings. A hybrid stud composed of steel and polymer was also developed. This hybrid stud, which is 150 SL in size, is made of a galvanized steel sheet (SGC58) and a glass fiber reinforced polymer (GFRP) withepoxy bonding. A total of 32 specimens were manufactured. Its parameters comprise two types of connection detail,s: the thickness of steel (1.0mm and 1.2mm) and of the GFRP (4mm-4ply and 6mm-6ply), and the ratio of the length to the depth (L/D = 3, 6, 9, 12). Steel stud specimens with the same conditions were compared to the hybrid stud. The test revealed that in the case of the steel specimen with a thickness of 1.0mm, the maximum load of hybrid studs increased an average of 1.62 times comparedto that of the steel stud. In the case of the steel specimen with a thickness of 1.2mm, on the other hand, the average increase was 1.46times. All specimens showed full composite action until the collapse.

Design and development of VSI Optical Adapter for high speed transmission of VLBI observation data (VLBI 관측데이터 초고속 전송을 위한 VSI 광변환 송수신 장치의 설계 및 개발)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Jung, Jin-Seung;Jung, Dong-Kyu;Oh, Chung-Sik;Ozeki, Kensuke;Onuki, Hirofumi;Harada, Keniichi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • This paper describes the design and development of VSI (VLBI standard interface) optical adapter for transmitting VLBI(Very long baseline interferometry) observation data with optical signal. VSI cable comprised of 80-line is being used for observed data transmission with maximum length of 5-meter between playbacks (Mark5B, VERA2000) and raw VLBI data buffer (RVDB), RVDB and VLBI correlation subsystem (VCS) in Daejeon correlator. It has a plan to conduct the data processing for 16-stations and introduce the 14 RVDB systems in near future. And data loss frequently occurred because of trouble of VSI cable MDR80 connector. By considering the data loss by connector error of VSI cable, RVDB system extension plan, effective space usage and long distance data transmission(e-VLBI), the VSI optical adapter was proposed and developed for effectively transmitting and receiving VLBI data through optical signal. In order to confirming the performance of developed VSI optical adapter, the experiments for data transmission was conducted between playback and RVDB system, and confirmed that data transmission was clearly done without any data loss.

Formation of Micron-sized Alginate Microparticles Using Reverse Micelles (역미셀을 이용한 마이크론 수준의 초미세 알긴산 입자 제조)

  • Imm, Jee-Young;Cho, Young-Hee;Han, Dae-Seok;Kim, Seok-Joong
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.835-840
    • /
    • 2003
  • Micron-sized alginate microparticles were formed in the water pools of reverse micelles (RM) composed of hexane/aerosol OT(AOT)/water through the gelation process between sodium alginate and $CaCl_2$. The size of microparticles formed increased as Wo (the molar ratio of water to surfactant) increased from 5 to 10. The microparticles became aggregated at Wo of 15, and stable RM no longer existed at Wo of 20. The characteristics of microparticles prepared at Wo of 5 and 10 showed significant differences in area, maximum diameter, minimum diameter, mean diameter, and perimeter of microparticles (p<0.05). However, there was no difference in appearance and roundness between the microparticles These results indicate that the size of microparticles are affected by Wo, whereas the overall shape of microparticles are not substantially influenced within Wo values used for stable RM formation. The mean diameter of microparticles was about $2{\sim}2.5\;{\mu}m$ and much smaller $(70{\sim}1,000\;times)$ than the reported sue of alginate microparticles formed in an aqueous medium.

Friction Welding of Ni-Base ODS Alloy Prepared by Mechanical Alloying (기계적 합금법으로 제조된 Ni기 산화물 분산강화 합금의 마찰압접에 관한 연구)

  • 강지훈;박성계;김지순;권영순
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 1994.10b
    • /
    • pp.15-15
    • /
    • 1994
  • M MA ODS 합금의 보다 폭넓용 실용확훌 위해 크게 요구되고 있는 적정 접합기술 개발의 한 방안£로, 마찰압접(Friction Welding) 방법의 가능성옳 조사하기 위하여 마찰압력과 시간, 마 찰 후 접촉압력(Upset Pressure) 풍을 다양하게 변화시켜 접합체톨 제조한 후, 접합체 강도에 대한 인장시험과 접합계연의 결합 및 미세구조에 대한 현미경 관찰, EDS에 의한 원소분석, 접 합이옴부의 경도분포와 파단면 분석 풍율 행하였다. 실험에 사용된 모재는 기계적 합금법으로 제조된 Inca사의 Ni기 MA 754 합금이었으며, 직경 l 10 mm, 길이 50 mm로 가공한 후, 아세통£로 초음파 세척하여 접합에 사용하였다. 접합온 브 레이크식 마찰압접기틀 사용하여 행하였으며, 회전시험편의 회전수는 2400 rpm이었A며, 다른 한쪽의 고정시험편과의 마찰압력 및 마찰시간온 각각 50 - 500 MPa과 1-5초로, 또한 업셋압 력도 50 - 600 MPa로 변화시켰다. 이때 업셋압력은 모든 시편에 대해 일정하게 6초동안 가하 였다. 얻어진 접합체는 각 압접조건 당 2개 이상의 접합시험편에 대해 상온 인장강도톨 측정하 였으며, 파단이 일어난 위치를 확인한 후 파면에 대한 분석율 주사전자현미경(SEM)과 에너지 분산형 분광분석기mDS)릎 사용하여 행하였다. 컵합이옴부의 첩합성올 확인하기 위하여, 접합 체를 접합변에 수직으로 절단, 연마한 후 광학현미경과 SEM, EDS 퉁으로 관찰, 분석하여 접 합부의 형상과 결합형성 여부, 접합계면의 미세조직 퉁옳 조사하였다. 또한 마찰압접에 따론 모재와 접합계연부의 경도분포훌 접합이옴부로부터 모재쪽으로 일정 간격율 두어 마이크로 비 커스 경도기로 측정, 조사하였다. 이상의 설험 결과, 다옴과 같온 결론옳 얻었다. ( (1) 접합체 강도가 모채 강도의 95% 이상이 되는 양호한 렵합체흩 얻기 위한 마찰압력 조건 온, 2400 rpm의 회전속도와 6초의 업셋압력 유지시간에서 마찰압력과 업셋압력, 그리고 마찰시 간이 각각 400 MPa 이상과 500 MPa 이상,2초입율 확인하였다. ( (2) 컵합이옴부의 관찰 결과, 모든 마찰압접 조건에서 컵합이옴부는, 기폰 모재의 texture 조직 을 유지하고 있는 모재부 영역(영역 ill)과 첩합계면부에 인접하여 업셋압력이 주어질 때 단조 효과에 의해 계연 외부로 metal flow가 일어나면서 형성된 영역 II, 매우 미세한 결정립으로 구성된 중앙부의 영역 1 로 이투어져 있옴융 확인하였다. ( (3) 최적접합조건이 충족되지 않온 경우, 접합부의 영역 I 에서 관찰된 void와 균열, 불균일한 접합계면 통의 접합결함에 Al과 Y. Ti 퉁£로 구성된 산화물률이 용집되어 있옴을 확인하였 다-( (4) 접합체의 파단 양상온 크게 접합부 파단과 모재부 파단, 이률의 혼합형 파단i로 나눌수 있었다. 모재부 파단의 경우, 파단면이 매끄럽고 파변상의 결정립도 매우 미세하였으며, 산확물 의 용집도 찾아보기 어려웠 나, 접합부 파단의 경우에는 파변의 굴곡이 비교척 심하고 연성 입계파괴의 형태를 보였£며, 결정립도 모채부 파단의 경우에 비해 조대하였다. 조대하였다.

  • PDF