• Title/Summary/Keyword: 전차선로

Search Result 249, Processing Time 0.02 seconds

The review of the safety for the development of insulated hanger in overhead contact line (전차선로 절연 행거 개발에 대한 안전성 검토)

  • Lee, Jae-Bong;Park, Weon-Chan
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1431-1440
    • /
    • 2009
  • A subway in Seoul has had a major role of public transportation after the opening of Seoul Subway Line 1 on August 15, 1974 and it has reached 34.7% of the transportation of Seoul citizens. The extended length of the subway system suppled with DC power in Korea is about 500km. In this system, the devices which are proper for regenerative power system are being required because of changeover from old braking and ATS signal system to regenerative braking and ATO signal system. In this paper, we reviewed the safety standards for the insulated hangers in overhead contact line. These hangers which have depended on foreign imports are being developed in Korea considering ease of demand and supply and economic effects.

  • PDF

A Study on Crashworthy Characteristics of EMU Carbody for Overhead Line Structure Types (전차선 지지 구조물 형태에 따른 전동차 차체의 충돌안전도 특성 연구)

  • Kim, Jin-Seok;Lee, Hyun-Cheol;Cho, Hyun-Jik;Koo, Jeong-Seo
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.381-387
    • /
    • 2007
  • In this paper, crashworthiness of the EMU carbody of Incheon Metro is numerically evaluated against two types of overhead line structures (headspan and portal-type). The material of the EMU carbody is stainless steel (SUS301L), and that of the overhead line structures is the structural steel (SS400). The EMU carbody is analyzed under collision conditions, such as upright side-on impact, side-on roof impact and angled roof impact scenarios, to be collided against the headspan type or the portal type at the speed of 64.4km/h, respectively. It is concluded from the numerical results that the overhead line structures will not do so much harm to the EMU carbody of Incheon Metro for various collisions caused by derailment. Furthermore, the overhead line structure of the portal type is superior to that of the headspan type in the crashworthy point of view.

Consideration on joint steel poles and beams for cartenary lines (전기철도 전차선로 지지물 강관주와 강관빔의 연결부 검토)

  • Song, Joong-Ho;Cho, Keun-Chul
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1334-1340
    • /
    • 2004
  • Existing of angle assembly and angle beam joint examination with steel pole and steel beam of assembly existing anglerather then excellent enumerate, joint of beanding moment examination and economical existing show, in the futher, angle beam rather then steel I beam with all change.

  • PDF

A Technical Review on the Structure Design Criteria for a Catenary System with Maximum Design Speed of 200 km/h (200 km/h급 전차선로 구조강도 설계기준에 관한 기술적 검토)

  • 조용현;이기원;권삼영;최강윤;창상훈
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.273-280
    • /
    • 2001
  • In this study, a comparison between the structural design criteria for a catenary system with the maximum design speed of 100km/h and that of 300km/h was performed in order to establish that of 200km/h. According to the result, catenary design criteria for 300km/h operation is more conservative than that for 100km/h operation. This result shows that higher wind pressure and safety factor are adopted to catenary design for 300km/h operation. So, for the purpose of the economic structural design for catenary system, it is necessary to review the adoption possibility of catenary system for 100km/h operation first. In order to review the adoption possibility for catenary system for 100km/h operation, design criteria for 300km/h operation should be chosen for safer catenary structure.

  • PDF

A Study on the Analysis and Measurement for the Elasticity of the Catenary System (전차선로 탄성도 해석 및 측정에 관한 연구)

  • 조용현;최강윤;조기조;권삼영
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1100-1105
    • /
    • 2002
  • The elasticity of the contact wire is one of important static parameters for the catenary system. This paper presents how to analyse the elasticity of the catenary system using both simple string model method and finite element method with their formula. Analysis results obtained by these two methods for KTX catenary system are compared. A measurement of the elasticity for the KTX catenary under construction which is located near Kumkang bridge is made for the comparison with the analysis results. Both a dynamic and a static methods are tried for the measurement. Because of wave propagation, the dynamic method with 5 km/h running presented an asymmetric variational pattern of the elasticity while the static method presented a symmetric pattern of the elasticity in the span. Measured elasticity using the static method is found to be a little higher than the analysis results. But, the static method can presented us a variational pattern of the elasticity in the span similar to the analysed results. Therefore, the static method can be used for evaluating the elasticity of the catenary system

  • PDF

A Reduced Equivalent 5 conductors Modeling of the Catenary System (전차선로 시스템의 5 도체 등가 축약 모델링)

  • 이한민;오광해;이장무;창상훈;장길수;권세혁
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.12
    • /
    • pp.684-690
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model, then the line constants of this equivalent five-conductors model are calculated. This paper shows the reducing process about the real system of the field by using the proposed theory. Also the line constants of reduced system are provided in this paper.

A Reduced Equivalent model of the Catenary System (전차선로 시스템의 등가 축약 모델)

  • Lee Hanmin;Oh Kwanghae;Lee ChangMu;Han Moonseob;Chang shanghoon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.415-420
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model by using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model. And then we calculate line constants of this equivalent five-conductors model. This paper shows the reducing process about the real system of the field by using the proposed theory and also line constants of reduced system

  • PDF

Development of Calcutation Software for Dropper Length (전차선로 드롭바 길이 계산프로그램 개발)

  • Lee Kiwon;Kwon Sanmyoung;Kim Joorak;Jang Donguk
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.421-426
    • /
    • 2003
  • Dropper which can get to suspend contact wire should be installed with a uniform distribution, so that electric locomotive can have good characteristics of current collection. Because dropper distribution is changed according to a circumstances in the construction field, it is hard to calculate and construct a overhead line. Therefore, in this study, a program was developed to calculate the dropper length in the normal and elevation section. Through the program, it is possible to perform a accurate construction of overhead line and contribute to a improvement of current collection as well.

  • PDF

A Suggestion for Improvement of Hanger length adjusting method in Trolley Wire Line (전차선로 행거의 길이조절방식 개선방안)

  • Kim Gyun-Sig;Park Han-Cheol;Park Han-Yong;Cha Kwang-Seok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.730-735
    • /
    • 2005
  • In this thesis, As electric railway vehicle's speed becomes faster and faster and functional, the conditions of operation (or running condition) of the vehicle also become complicated and diverse. As the number of electric vehicle increases by enhancement of the running condition, problems are also raised in circulation current, vibration and unstable contact caused by equipment(sporting part for making horizontal between Trolley wire and Messenger wire) and troubles in Ark by un secure contact. This articles shows a method to prevent or to have least problem of vibration, and unstable contact by having constant height of Trolley wire through adjusting the length of Hanger.

  • PDF

Optimal Design of a High-Speed Linear Synchronous Motor in a Dynamic Tester for Catenary Current Collection (전차선로-집전계 주행시험기 추진용 고속 선형동기전동기의 최적설계)

  • Lee, Hyung-Woo;Kwon, Sam-Young;Lee, Byung-Song;Park, Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.665-674
    • /
    • 2006
  • This paper presents the optimal design of a high-speed (200[km/h]) Linear Synchronous Motor which will be used as a propulsion system of a dynamic tester for catenary-current collection used in railways. Motor performance, especially detent force minimization on various design schemes has been investigated in detail by using FEM (Finite Element Method). Simulation-based DOE (Design of Experiments) method is also applied in order to reduce the large number of analysis according to each design variable and consider the effect among variables. The optimal design in all aspects is proposed by an optimization algorithm using a regression equation derived from the simulation-based DOE and the performance is verified by FEM.

  • PDF