Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices (가정용 전자식 혈압계의 정확도에 대한 임상적 평가)

  • Choo Ji-Na
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.9 no.1
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device (홀소자를 이용한 손목착용 맥진기의 혈압추정 알고리즘)

  • Ahn, Myung-Cheon;Cho, Jong-Gu;Son, Il-Ho;Lee, Sang-Suk;Kim, Kuen-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.106-113
    • /
    • 2010
  • In order to get the precise blood pressure and pulse number in the cuffless status, the wrist wearable pulsimeter with a portable and small size apparatus using by Hall device is developed. The regression analysis of the pulse wave measured by the testing product of pulsimeter is conducted two equations of the blood pressure algorithm. The estimated values of blood pressure obtained by the cuffless pulsimeter during 5 s are compared with the practical values measured by electronic or mercury liquid blood pressure meters. The standard deviation of the estimated value and the practical value for the high blood pressure and the low blood pressure were 12.1 and 5.9, respectively, which have the neighborhood values of BP International Standard. The detail analysis of a pulse wave measured by cuffless wrist wearable detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus like as the wrist wearable pulsimeter.

Comparison of Sphygmomanometer, Fully Automatic Electronic Blood Pressure Meters with Standard Digital Blood Pressure Monitor : Pilot Study (표준전자식 혈압계와 수은혈압계, 전자혈압계의 비교 선행연구)

  • Yahng, J.S.;Lim, H.K.;Cho, D.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.155-162
    • /
    • 2012
  • Devices to measure the blood pressure of patients are being used without any calibration in a hospital. It is an important to show consistent values when any medical devices measure the same patients regardless they are sphygmomanometer or fully automatic electronic blood pressure meter. We compared sphygmomanometer and fully automatic electronic blood pressure meters with standard digital blood pressure monitor (SDBPM) to evaluate the consistency of the small healthy subjects. We measured the blood pressure from six healthy subjects (three of 20~40 years and three of 40~60 years old). Two sphygmomanometer and two fully automatic electronic blood pressure meters were used and compared with the SDBPM. Blood pressures measured from right and left arms each and were compared. All six healthy subjects showed normal blood pressure values. In general, left blood pressure values showed higher values than right side. Comparing SDBPM, with the other monitors, the systolic pressure showed ${\pm}$ 34.8% difference and ${\pm}$ 33.3% for the diastolic pressure. Correlation between SDBPM and Sphygmomanometer was 0.59~0.71, and 0.50~0.70 for fully automated digital BP monitors. It fell in grade-D when we apply the BHS(British hypertension society). AAMI(American association for the advancement of medical instrumentation) also showed unsatisfactory results for the mean value (${\leq}$ 5 mmHg) and standard deviation (${\leq}$ 8 mmHg). We tested sphygmomanometer and fully automatic electronic blood pressure meters and compared with a standard digital blood pressure monitor. All devices showed inconsistent blood pressures. A reliable calibration system is highly needed for all devices in all hospitals.

뇌혈류 자가조절과 내인성 $K^{+}$ channel 개방물질에 대한 연구

  • 홍기완
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.85-85
    • /
    • 1993
  • 뇌동맥계는 일과성 저혈압에 반응하여 혈관확장이 야기되고, 혈압 상승시에는 혈관수축이 일어남으로서 뇌혈류가 일정하게 조절된다. 이러한 자가조절은 뇌손상 등의 병적 상태에서 야기된다. 연구의 목적은 \circled1 Cromakalim, CGRP(calcitonin-gene related peptide), 및 substance P에 의하여 뇌연막동맥의 직경이 어떻게 변동하는가를 관찰하고 \circled2 이들 신경성 peptide의 작용에 대하여 $K^{+}$ 통로 개방 봉쇄제인 glibenclamide의 전처치 효과를 검색하고 \circled3 Capsaicin 전처치가 뇌혈류 자가조절에 어떻게 영향을 미치는가를 검색하였다. 그 결과는 다음과 같다. 1. 뇌혈류 자가조절은 대퇴동맥을 통한 사혈에 의하여 혈압하강을 일으킬 때 뇌연막 동맥은 이완하였고, reservoir내의 혈액을 체내로 주입함로서 혈압반전을 일으켰을 때는 혈관 수축이 일어났다. 2. 연막동맥은 glibenclamide (1~3$\mu$M)의 관류에 의하여는 영향을 받아니하였다. 3. 혈압변동에 따른 혈관직경의 변화를 회기직선으로 분석하였다. Glibenclamide 1과 3$\mu$M의 전처치 관류에 의하여 혈압하강에 따른 혈관 이완경사도와 혈압반전에 따른 혈관수축 경사도가 대조군에 비하여 현저히 약화되었다. 4. Cromakalim (0.1-30$\mu$M)의 각 농도를 대뇌표면에 관류시 연막동맥의 기초직경은 약물농도에 의존하여 증가되었고, 이는 glibenclamide (1$\mu$M) 전처치 관류에 의하여 억제되었다. 5. CGRP (0.1~100 nM)와 substance P (0.1~10nM)도 용량에 의존하여 혈관이완을 일으켰다. 전자는 glibenclamide (1$\mu$M) 전처치 관류에 의하여 억제되었으나 후자는 영향을 받지 아니하였다. 6. Capsaicin(50 nmol: intracisternally) 주사에 의하여 뇌혈류자가조절의 변동이 초래되었다. 이상의 결과들을 종합하면 CGRP가 혈압변동에 의하여 반사적으로 유리되고, 이는 glibenclamide-sensitive $K^{+}$ 통로에 작용하는 것으로 시사된다.

  • PDF

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF

A research on the sychronized clock pulse for the measurement of physical function. (안정된 동기시신호발생을 이용한 인체 기능의 측정에 관한 연구)

  • Lee, Haing-Se;Lee, Sang-Hyeok;Kim, Yong-Deuk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.5
    • /
    • pp.9-16
    • /
    • 1976
  • This paper deals with a method of measuring the temperature, purse, and pressure of a human body The temperature controlled oscillator was designed with a thermistor as a temperature measuring part The error in temperature was less than $\pm$0.05$^{\circ}C$ in the range of the temperature of a human body.

  • PDF

홍국주의 제조와 품질특성에 관한 연구

  • 유영주;황인식;정순택;박양균;김선재;박배선
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.148-148
    • /
    • 2003
  • 최근 홍국색소는 천연계착색료로서 뿐만 아니라 발효식품, 발효조미료등에도 이용되어 기호에 맞는 새로운 홍국 개발도 적극적으로 진행되고 있어 인지도가 높아지고 있다. 혈청콜레스테롤저하작용, 혈압강하작용, 혈당강하작용, 항산화작용등 여러가지 약리효능을 지닌 홍국균을 이용해 재래적 방법에 근거하여 홍국주를 제조하여 그 제조공정을 확립하고 품질특성을 확인하였다. Monascus purpureus를 액체배양법에 의해서 홍국코지를 제조하고 코지의 역가는 $\alpha$-amylase와 $\beta$-amylase 활성은 400unit와 4.44unit를 나타났으며, acid protease 활성은 80unit, neutral protease 활성은 91.4unit로 나타났다. 홍국코지에 증자된 쌀과 물을 혼합하여 발효경과를 측정하고, 발효가 끝난 홍국주의 DPPH법에 의한 전자공여능, 아질산염 소거능, Total phenolic compound함량, ACE저해작용등을 측정하였다. 홍국주의 발효경과 분석은 알콜도수는 2차 담금 후 2일째-13.2도, 4일-13.5, 6일째-13.5, 8일째-13.5, 10일째-13.4로 나타났다. 환원당은 2일째-23.26, 4일-20.68, 6일째-21.74, 8일째-19.93, 10일째-14.23 $^{\circ}$Brix로 점점 감소한다는 것을 볼 수 있으며, 색도에서 적색을 나타태는 Hunter value a값은 2일째 -14.72, 4일-14.97, 6일째-15.70, 8일째-16.43, 10일째-17.29로 시간이 지날수록 붉은 색소가 증가한다는 것을 알 수 있었다. pH는 2일째-4.52, 4일-4.02, 6일째-4.11, 8일째-13.11, 10일째-13.18로 pH가 약간 낮아진 것을 볼 수 있다. 산가는 2일째-8.4, 4일-6.7, 6일째-7.0, 8일째-7.5, 10일째-11.5로 pH가 산성화 될 수록 산가는 증가하는 것을 볼 수 있다. 홍국주의 전자 공여능에 의한 항산화력은 25.6%, 아질산염 소거능은 27.6%, Total phenolic compound 함량은 12.34mg%, ACE저해작용은 38%의 항산화력을 나타냈다.

  • PDF

하계 전기, 전자연합학술회의 및 산학협동 심포지엄 초록

  • 대한전기학회
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.33-54
    • /
    • 1978
  • (차례) 1.산학협동심포지업 (1)우리나라에서의 연구개발과 산학협동 (2)산학협동과 산업계의 역할 (3)산학협동의 현황과 진로 2.학술회의A (1)전력게통의 계층구조와 협조원리에 관한 연구 (2)2중층괴상회전자 유도전동기의 이론해석 (3)초고주파가열장치에 사용하는 철공진변압기의 해석적 설계 (4)한국전기기시험연구소 대전력단락 시험설비설계 (5)직류전동기제어를 위한 Thyristor Chopper정류회로에 관한 연구 (6)선로의 개폐정보를 포함하는 전력계통의 상태추정 (7)단일신경세포에 대한 ITEM 신호 특성 3.학술회의B (1)MMM-1 Computer System의 설계 및 제작 (2)Adaptive Delta Modulation System의 성능비교 연구 (3)6GHZ FMD마이크로파 무선전송장치의 개발 (4)적선도에 의한 회로망함수의 결정 (5)동맥혈압의 해석과 그의 전기적 유사모델 (6)피부감각의 정보전달 특성에 관하여 (7)선형직접회로의 공정설계 및 그 특성 조성 (8)DH L.D의 전기적포화현상에 관한 이론적 해석 (9)Potocoupler를 이용한 Isolator 4.학술회의C (1)Al-Al$_{2}$O$_{3}$ -Al박막구조의 전기적 특성 (2)이종금속에 샌드위치된 고분자물질의 단락전조 (3)유전체가 일부체워진 직 6면체의 캐비티의 다중모오드 해석 (4)반도체 가스 검지소자의 제조 및 그의 전기적 특성 (5)실리콘 산화공정에 대한 실험적 고찰 (6)진공증착법에 의한 InSb 박막제도에서 열처리효과 (7)(Ba$_{1}$-xBix) Tio$_{3}$ PTC thermistor의 첨가량의 최적건안 (8)금속박막증착시 두께조절 5.특별강연회 (1)일본에 있어서의 절력계통공학연구 (2)Linear Motor의 최근개발동향량도 높았다. valine과 leucine 및 aspartic acid, glycine과 glutamic acid, leucine과 aspartic acid 간에는 고도의 정상관, glycine과 serine, valine과 phenylalanine, threonine과 proline, phenylalanine과 arginine, methionine과 glutamic acid, histidine과 lysine 간에는 유의 정상관, 그리고 isoleucine과 lysine 간에는 유의한 부상관이 있었다. 4. lysine 함량은 단백질 함량과 정산곤, isoleucine 함량은 단빅질 함량과 부상관을 보였으며, alanine, valine, leucine 함량은 지방함량과 각각 유의한 정산관을 보였다. 5. 대두 단백질은 7.5% acrylamide gel 전기영동에 의해 품종에 따라 12~16개의 구성분으로 분리되었으며, 이들중 주구성분들은 상대이동도가 0.06(a), 0.14(b). 0.24(d) 이었고, 구성분 b의 함량이 품종간에 가장 변이가 컸으며, 구성분 b는 그밖의 주요 구성분들의 함량과 부의 상관이 있었고, 구성분 a는 단백질 함량과 정상관이 있었다. 6. 종실단백질 구성분들의 조합 특성 면에서 공시 86품종은 11개 유형군으로 분류되었으며, 우리나라와 일본품종은 미국품종에 비해 단백질구성분 조성이 훨씬 다양하였다. 7. 이동도가 매우 빠른 단백질 구성분 o(Rm 0.77) p(Rm 0.81)를 모두 갖고 있는 품종은 3품종, 모두 갖고 있지 않은 품종은 1품종이었고, 나머지 82품종은 o나 p중 한 구성분을 갖고 있었으며 그 분포율은 30 : 65 이었는데 미국계 품종은 우리나라 품종에 비해 구성분 o를 간고 있는 비율이 현저히 적었다. 8. 대두 종실은 개화후 22일까지 완만히, 그 이후 20~30일간 급속히

  • PDF

Analysis of causal factors and physical reactions according to visually induced motion sickness (시각적으로 유발되는 어지럼증(VIMS)에 따른 신체적 반응 및 유발 요인 분석)

  • Lee, Chae-Won;Choi, Min-Kook;Kim, Kyu-Sung;Lee, Sang-Chul
    • Journal of the HCI Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 2014
  • We present an experimental framework to analyze the physical reactions and causal factors of Visually Induced Motion Sickness (VIMS) using electroencephalography (EEG) signals and vital signs. We studied eleven subjects who are voluntarily participated in the experiments and conducted online and offline surveys. In order to simulate videos including global motions that could cause the motion sickness, we extracted global motions by optical flow estimation method from hand-held captured video recordings containing intense motions. Then, we applied the extracted global motions to our test videos with action movies and texts. Each genre of video includes three levels of different motions depending on its intensity. EEG signal and vital sign that were measured by a portable electrocorticography device and an electronic monometer in real time while the subjects watch the videos including ones with the extracted motions. We perform an analysis of the EEG signals using Distance Map(DM) calculated by correlation among each channel of brain signal. Analysis using the vital signs and the survey results is also performed to obtain relationship between the VIMS and causal factors. As a result, we clustered subjects into three groups based on the analysis of the physical reaction using the DM and the correlation between vital sign and survey results, which shows high relationships between the VIMS and the intensity of motions.

A COMPARATIVE STUDY ON THE VITAL SIGN AND BEHAVIOR APPEARANCE DEPENDING ON THE ROUTE OF FLUMAZENIL ADMINISTRATION IN CONSCIOUS SEDATION BY MIDAZOLAM (Midazolam을 이용한 의식진정시 flumazenil의 투여경로에 따른 생징후 및 행동양상의 비교 연구)

  • Kim, Hyun-Sik;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.159-167
    • /
    • 2002
  • The purpose of this study was to evaluate the efficacy and safety depending on the route of flumazenil, as an antagonist against midazolam. The subjects of this study were 15 volunteers of $22{\sim}24$ years old. They were sedated with midazolam 0.2mg/Kg intranasal spray, and then 40 minutes after midazolam administration, they were given flumazenil 0.2mg intranasal spray for their reversal. For evaluation of the efficacy and safety of intranasal spray for flumazenil, they were monitored with pulse-oxymeter(Nellcor symphony N-3000, Nellcor Puritan CO. USA) and electric sphygmomanometer (Heartcare 200, National CO. Japan), and were assessed themselves using visual analogue scale(VAS) for tranquilization, sleep, fatigue and attitude. All of these subjects were reduced completely without any undesired situations. The results from this study can be summarized as follows ; 1. Nasaly administered flumazenil using spray device produced much more rapid reduction than intravenously administered flumazenil, but soon after fell in more deep sedated state than intravenously administered flumazenil. 2. There were no considerable side effects or bad influence on vital signs of both nasaly administered flumazenil and intravenously administered flumazenil. These results suggested that the flumazenil administered nasaly using spray device for reversal, we could treat patients safely and effectively under conscious sedation using midazolam administration. But, We will have to research about its optimal dosages for flumazenil, used as intranasal spray for reversal agents against the midazolam by evaluating the blood plasma concentration of midazolam and flumazenil.

  • PDF