• Title/Summary/Keyword: 전자파 간섭(EMI)

Search Result 51, Processing Time 0.026 seconds

A Study on the Radiated Emission from the DC Power-Bus for the PCB (PCB DC Power-Bus로부터의 전파 방사에 관한 연구)

  • Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.148-151
    • /
    • 2006
  • The DC power-bus' resonance is frequently attributed to EMI sources in the PCBs. Subsequently, it will ruin the digital signal integrity within one system or between adjacent systems in the form of conducted or radiated emission. Hence, since it is of importance to examine the PCB's emission, this paper sheds a light on the radiated emission from the power-bus with regards to its resonance modes. A full-wave analysis method is used to calculate the impedance and radiated electric fields and is validated by physics and an EM analysis tool.

A Study of Block Structures for Improving the Electromagnetic Shielding Properties (전자파 차폐성능 향성을 위한 건축용 블록의 형상 연구)

  • Lim, Gye-Jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.4
    • /
    • pp.175-179
    • /
    • 2012
  • In this paper, we proposed the modified block structures with enhanced electromagnetic shielding properties for mobie communications and ETC frequency bands. As the result of measurement, this block structure with optimized design has the shielding properties of 30 dB, and can be used for electromagnetic safety and EMI.

Recent Trends in System-Level EMC Investigation and Countermeasure Technology for RF Interference Due to High-Speed Digital System Noise (고속 디지털 시스템 잡음에 의한 RF 시스템 간섭(RFI) 현상에 관한 시스템 레벨의 EMC 분석 및 대책 기술 연구 동향)

  • Koo, Tae-Wan;Lee, Ho Seong;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.966-982
    • /
    • 2014
  • This paper presents recent trends in system-level EMC investigation and countermeasure technology for radio frequency interference (RFI) influenced by noise generated in high-speed digital system. Recently, as the only digital device can perform various roles, there are a variety of EMI/EMC problems between systems. Especially, RFI is now recognized as a major problem, which occurs by EMI caused by the digital system. Therefore, in this paper, recent trends of RFI investigation from component-level to system-level are introduced and analyzed. Furthermore, in order to solve the RFI problem, recent researches are presented and investigated for the occurrences and suppression methods of common-mode noise which is one of the major noise sources in high-speed digital system. Lastly, this paper suggested future research of system-level EMC analysis and countermeasure technology for RFI problems.

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

Numerical Analysis of Electromagnetic Characteristic of High Voltage/Current Cable for Fuel Cell Electric Vehicle (FCEV) (수소 연료전지 차량용 고전압 케이블의 전자파 특성 수치해석에 관한 연구)

  • Lee, Soon-Yong;Choi, Jae-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.149-157
    • /
    • 2010
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) is essential. BOP systems are used many not only for motors in water pump, air blower, and hydrogen recycling pump but also inverters for these motors. Since these systems or components are connected by high voltage cables, EMC (Electromagnetic compatibility) analysis for high voltage/current cable is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields of high current/voltage cable for FCEVs is studied. From numerical analysis results, time harmonic magnetic field strength of high current/voltage cable have difference of 20~28 dB according to phase. EMI result considered ground effect of FECV at 10 m shows difference of 14.5 dB at 30 MHz and 2.8 dB at 230 MHz compared with general cable.

Paratic Impedance Extraction of FC-PGA Package Pin using the Static Fast Multipole Method (Static FMM을 이용한 FC-PGA 패키지 핀에서의 기생 임피던스 추출)

  • 천정남;이정태;어수지;김형동
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1076-1085
    • /
    • 2001
  • In this paper, the FMM(Fast Multipole Method) combined with GMRES(Generalized Minimal RESidual Method) matrix solver is used to extract the parasitic impedance for complicated 3-D structures in uniform dielectric materials which limit the use of MoM(Method of Moment) due to its large computation time and memory requirement. This algorithm is a fast multipole-accelerated method based on quasistatic analysis and is very efficient for computing impedance between conductors. This paper proved the accuracy and efficiency of the FMM by comparing with MoM in simple examples. Finally the parasitic impedance of FC-PGA(Flip Chip Pin Grid Array) Package pins has been extracted by this algorithm and we have considered the possibility of the EMI/EMC problem caused by the signal interference.

  • PDF

A Study on Electromagnetic Interference Shielding Effectiveness of the Metal Powders and Nano Carbon black /Fiber Reinforced Epoxy composites (메탈 파우더와 나노 카본 블랙/섬유강화 복합재료의 전자파 차폐효과에 관한 연구)

  • Han Gil-Young;Kim Jin-Seok;Ahn Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.100-107
    • /
    • 2006
  • The objective of this research is to investigate the electromagnetic interference(EMI) shielding characteristics of fiber reinforced composites. We fabricated glass and carbon fiber reinforced composites filled with metal powder and nano carbon black. The measurements of shielding effectiveness(SE) were carried out frequency range 300MHz - 1GHz for commercial purposes such as electric or telecommunication devices. The return loss and loss due to absorption were also measured as a function of frequency in the micro wave(300MHz-1GHz) region. It is observed that the SE of the composites is the frequency dependent, increase with the increases in filler loading. The Mg metal powder filled composite showed higher SE compared to that of carbon black. The Mg metal powder/epoxy composite was shown to exhibit up to 40dB of SE. The results indicates that the composite having higher filler loading can be used for the purpose of EMI shielding as well as for some microwave applications.

Development of EMC filter for electronic equipments mounted on ships (선박 탑재 전자기기용 EMC 필터 개발)

  • Kim, Dong-Il;Kim, Eun-Mi;Jeon, Mi-Hwa
    • Journal of Navigation and Port Research
    • /
    • v.34 no.1
    • /
    • pp.33-37
    • /
    • 2010
  • It is very important to prevent the electromagnetic interference and to prevent malfunction of electronic equipments mounted on ships. To solve these problems, in this paper, the EMC filter was designed, fabricated, and tested. The Ni-Zn ferrite beads with high permeability were used to make large inductance as the inductor and the feed-through capacitors without any resonance points. As a result, excellent attenuation characteristics of 25~70 dB were obtained from the 0 kHz~1.5 GHz band. In addition, when the Electric Fast Transient (EFT) of 4 kV in the level 4 of IEC 61000-4-4 was induced the EFT reduced to 600 V. Therefore, it was clearly shown that the developed EMC felter can be used for suppressing the electromagnetic interference on-board electronic devices and equipments.

EMC filter development for ships mounted electromagnetic (선박 탑재 전자기기용 EMC 필터 개발)

  • Kim, Eun-Mi;Jeon, Mi-Hwa;Kim, Dong-Il
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.183-184
    • /
    • 2009
  • In this paper the internal or external of the ships mounted electronic devices due to the propagation of electromagnetic interference and to prevent malfunction EMC filter was designed and fabricated. It was designed and fabricated with Ni-Zn ferrite beads of high permeability to make large inductance as the inductor and Feed-through capacitors, which did not have any resonance point, to restraint resonance effectively, and the characteristics was evaluated. The results from the 0 kHz$\sim$1.5 GHz bandwidth of $25{\sim}70$ dB were able to obtain excellent attenuation characteristics. And, when the Electric Fast Transient (EFT) of 4 kV in the level 4 of IEC 61000-4-4 was induced, it was soon attenuated more than 1/6 to 600 V. Therefore, it was confirmed that the developed EMC filter can be used for suppressing ships mounted electromagnetic interference between electronic devices.

  • PDF

Numerical Analysis of Electromagnetic Radiation Characteristics by High Voltage and General Cables for Fuel Cell Electric Vehicle (FCEV) (수소 연료전지 차량용 고전압 케이블과 일반 케이블에 의한 차량 전자파 방사 특성 수치해석 연구)

  • Lee, Soon-Yong;Seo, Won-Bum;Lim, Ji-Seon;Choi, Jae-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) which is consisted of many motors in water pump, air blower, and hydrogen recycling pump as well as inverters for these motors is essential. Furthermore, there are also electric systems for entertainment, information, and vehicle control such as navigation, broadcasting, vehicle dynamic control systems, and so on. Since these systems are connected by high voltage or general cables, EMC (Electromagnetic compatibility) analysis for high voltage and general cable of FCEV is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields by high voltage and general cables for FCEVs is studied. From numerical analysis results, total time harmonic electromagnetic field strength from high voltage and general cables have difference of 13~16 dB due to ground effect by impedance matching. The EMI results of FECV at 10 m distance shows difference of 41 dB at 30 MHz and 54 dB at 230 MHz compared with only general cable routing.