Design of Brushless DC Motor Speed Control System for Handpieces (핸드피스용 BLDC 모터 속도 제어시스템의 설계)

  • Kwak, Seong-Woo;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.597-604
    • /
    • 2016
  • In this paper, we develope a speed control system of a BLDC motor for handpieces used in beauty applications. To reduce implementation cost, the control system utilizes hall sensors embedded in BLDC motors for speed estimation. The developed power module of a motor uses only 220V home voltage, so that the control system does not need any other power sources. An over-speed limit controller is also developed to slow down a motor when the speed goes up rapidly for a moment upon some heavy load is removed. The control system is designed to operate a handpiece with speed in the range of 5,000~30,000 RPM. Experiment results show the validity of the developed system, which maintains the speed of a motor steady even though a load is varied.

A Study on a Traffic Signal Operation system using complex Sensor (복합 센서를 이용한 교통 신호운영체계에 관한 연구)

  • Hwang, Gui-Youn;Jeong, Yang-Kwon;Choi, Hyung-Ju;Hui, Xue-Wu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.10
    • /
    • pp.1573-1580
    • /
    • 2013
  • This study is proposed traffic signal operating system to find existing problems of loop system and complex with doplar system, which have strong linearity, resistence of weather effects and wide range to improve delay problems that used in vehicle detection method. This proposed method have simulated on Southern-Gwangju station to Enter of SeoChang take about 10km by using VISSIM tool and we found this proposed method is 15% through(또는 to) 30% more effective than continuous progress interlocking system or crossing progress interlocking system.

Feedback Linearization Control of PWM Converters with LCL Input Filters (LCL 입력 필터를 갖는 PWM 컨버터의 궤환 선형화 제어)

  • Kim, Dong-Eok;Lee, Dong-Choon;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.55-62
    • /
    • 2008
  • This paper proposes a feedback linearization control scheme of AC/DC PWM converters with LCL input filters using no damping resisters. This feedback linearization scheme can eliminate the non-linearity of the system. So, the controller of the system can be designed by using linear control theory, which gives a good transient response. The cascade structure of the controller makes the converter current be controlled within a certain limit. To reduce the number of sensors, the source voltage and current is estimated. The validity of the proposed control algorithm is verified by simulation and experimental results.

Modeling of a Superconducting Flux Flow Sensor Inductance Radiometer (인덕턴스 복사계 측정을 위해 사용된 초전도 자속 흐름 센서기 모델링)

  • Ko, Seok-Cheol;Kang, Hyeong-Gon;Lim, Sung-Hun;Choi, Myong-Ho;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.19-22
    • /
    • 2003
  • For use in constructing highly sensitive thermal detectors, the present authors have been studying the preparation of Superconducting Flux Flow Sensor(SFFS). In this research, SFFS with five channel ($5{\mu}m$/1channel) has been fabricated based on the flux flow using high temperature superconducting thin films by the ICP etching technique. We have designed a bolometer based on the temperature dependence of the kinetic inductance of a superconducting flux flow thin film. In this paper examines the fabrications and flux flow resistance and thermometer responses of the highly sensitive sensor constructed of a thin YBCO film. It is also suggested that they will be applicable to a new type of flux flow sensor.

  • PDF

The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings (6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계)

  • Lim, Kwang-Jin;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

Single-Phase Utility-Interactive Inverter for Residential Fuel Cell Generation System (가정용 연료전지 발전 시스템을 위한 단상 계통연계형 인버터)

  • Jung, Sang-Min;Bae, Young-Sang;Yu, Tae-Sik;Kim, Hyo-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • In this paper, a new single-phase utility-interactive inverter system for residential power generation with fuel cell is proposed. The proposed inverter system is not only capable of working in both stand-alone and grid-connected mode, but also ensures smooth and automatic transfer between the two modes of operation. The proposed control method has little steady-state error and good transient response characteristic. Also, the control method can be implemented using low-cost, fixed point DSP since it has simpler structure, smaller amount of calculation, and smaller number of sensors. The controller for the proposed utility-interactive inverter system is described, and the validity is verified through simulation and experiment.

Input Voltage Sensorless Control for 3 Phase Vienna Rectifier (3상 비엔나 정류기 입력 전압 센서리스 제어)

  • Lee, Sang-Ri;Kim, Hag-Wone;Cho, Kwan-Yuhl;Hwang, Soon-Sang;Yoon, Byung-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 2014
  • In this paper, a new grid voltage estimation algorithm without voltage sensors is proposed for the three-phase vienna rectifier. Generally, input voltage sensor circuits increase size and cost of the PWM rectifier In order to reduce the cost and size and in order to increase reliability from the electrical noise, grid voltage estimation scheme without input voltage sensor is highly required. In this paper, the grid voltage estimation algorithm is proposed by a simple MRAS(Model Reference Adaptive System) observer without input voltage sensors. The validity of the proposed method is proven by simulation and experiment on the three-phase vienna rectifier system.

A Study on the Fault Detection Technique of the Grid-Connected Photovoltaic System using Wavelet Transformation (웨이블렛 변환을 이용한 태양광 발전시스템의 고장진단에 관한 연구)

  • Lee, Jeong-Eun;Kim, Il-Song
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2011
  • The fault detection technique of the grid-connected photovoltaic system using wavelet transform has been suggested in this paper. The additional hardware and sensors are required to detect the inverter failure in the conventional method, and it has the disadvantage of high cost and re-design problem if the inverter specification has been changed. The suggested method used the inverter voltage and current waveform to detect the failure and the location by the wavelet coefficients variations. The prompt and accurate diagnostic function is possible using the normalized standard deviation method. The merit of the proposed method is the simple calculation and precise diagnostic capabilities of the fault detection. The computer simulation is performed and the experimental result verifies the validity of the proposed method.

PD Diagnosis On High Voltage Rotating Machines using UWB Sensor (UWB 센서 설계를 통한 고압회전기의 부분방전 진단 연구)

  • Lwin, Kyawsoe;Lim, Kwang-Jin;Shin, Dong-Hoon;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.197-198
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic pulse emitted from the partial discharge source in the stator winding of HV Rotating Machine with UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on micro-strip technology and made experiments of offline dismantled testing compare with the traditional HFCT as a reference sensor in the laboratory. We investigated internal discharge, surface discharge, corona discharge and non-defected state normal stator on pre-made stator winding by using UWB patch sensor.

  • PDF

WBAN Service Quality Optimization Design Using Error Correction Technique (에러교정기법을 이용한 WBAN 서비스품질 최적화 설계)

  • Lee, Jung-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.657-662
    • /
    • 2019
  • The power consumption of wearable sensors and electrocardiogram regulators should be very low to extend the network lifetime and anticipated QoS( : Quality of Service) control such as error correction and authentication of data processed by WBAN( : Wireless Body Area Network) nodes is important. Therefore, QoS control is the most urgent concern to implement WBAN in health monitoring regulations. For optimal QoS control, we compare the energy efficiency and the average number of transmissions with IEEE 802.15.6 and the error correction method considering energy efficiency. The performance of the proposed error correction technique shows that the energy efficiency and the transmission rate are improved by adjusting the coding rate appropriately using the channel estimation.