• Title/Summary/Keyword: 전자간부

Search Result 9, Processing Time 0.019 seconds

A Redesign of the Military Education Structure of General Universities based on Defense Innovation 4.0 -Focused on Capabilities of Tech-Intensive Junior Officers based on Advanced S&T- (국방혁신4.0 기반의 일반대학의 군사학 교육체계 재설계 방안 -첨단과학기술 기반의 기술집약형 초급 간부 역량 중심으로-)

  • Jung-Ho Eom;Keun-Seog Park;Sang-Pil Chun
    • Convergence Security Journal
    • /
    • v.22 no.4
    • /
    • pp.35-44
    • /
    • 2022
  • Among the five promotion strategies of Defense Innovation 4.0(DI 4.0), the military structure/operation optimization strategy aims to innovate the military structure based on advanced science&technology(S&T), and to integrate advanced S&T in the field of defense operation such as education&training and human resource development. As the future battlefield expands to AI-based unmanned/robot combat systems, space, cyberspace, and electromagnetic fields, it is necessary to train officers with the capabilities required in these battlefields. It is necessary to develop capabilities from junior officers who will lead the future battlefield to operating core advanced power based on the 4th industrial revolution S&T. We review the education system of the military in universities and propose a method of redesigning the education system that is compatible with DI 4.0 and can develop technology-intensive capabilities based on advanced S&T. We propose a operation plan of major and extra-programs that can develop the capabilities of junior officers required for the future battlefield, and also suggest ways to support the army's practical training.

The Difference between Short and Long Intramedullary Nailing as the Treatment for Unstable Intertrochanteric Femoral Fracture (AO/OTA 31-A2) in Elderly Patients (고령환자에서 발생한 불안정성 대퇴골 전자간부 골절(AO/OTA 31-A2)의 치료 시 골수강내 금속정의 길이에 따른 추시 결과)

  • Shin, Won Chul;Lee, Eun Sung;Suh, Kuen Tak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.25-32
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the radiological and clinical outcomes in elderly patients with unstable intertrochanteric femur fractures in accordance with the length of intramedullary nail. Materials and Methods: Between August 2009 and December 2014, a total of 139 patients-older than 65 years of age with AO/OTA classification of 31-A2 unstable intertrochanteric femur fracture-who has been followed-up for at least 1 year after the treatment with internal fixation by using an intramedullary nail were enrolled for this retrospective control study. The subjects were classified into two groups according to the length of intramedullary nail: 106 patients in the short group (group I) and 33 patients in the long group (group II). For radiological assessments, the reduction state, time to union, and implant related complications were examined. The clinical outcomes were assessed by preoperative hemoglobin, operating time, intraoperative bleeding amount, blood transfusion rate, hospitalization period, and Charnley hip pain scoring system at the final follow-up. Results: The postoperative radiographs showed good or acceptable reduction in all cases. The mean time of radiologic bone union was 4.8 months, and there was no difference between the two groups. With respect to surgical time, the group II was found to take longer (57.87 minutes) than the group I (45.65 minutes) (p=0.003). The bleeding amount during surgery of the group II was greater (288.78 ml) than that of the group I (209.90 ml) (p=0.046). The clinical results at the final follow-up were found to be satisfactory in both groups. Conclusion: In cases of good reduction of the fracture from the treatment of unstable intertrochanteric femur fracture accompanying the posteromedial fragment in elderly patients, both groups-long and short intramedullary nails-showed satisfactory radiological and clinical outcomes.

A study on the micro-structural and biomechanical properties of trabecular bone in intertrochanteric region (대퇴골 전자간부 해면골의 미세구조적 특성과 생역학적 특성에 관한 연구)

  • Baek M.H.;Won Y.Y;Cui W.Q.;Kim K.K;Kim H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.923-926
    • /
    • 2005
  • To investigate the relationship between BMD, micro-structural and mechanical properties in intertrochanteric trabecular bone, the PIXI-mus2 system, micro-CT and FE model were used. The purpose of this study were (1) to apply high-resolution imaging techniques (micro-CT imaging) in combination with new computer modeling techniques (FEA) to quantify 3D microstructural and biomechanical properties of trabecular bone in the intertrochanteric region, and (2) determine if the prediction of bone elastic constant can be improved with structural index.

  • PDF

Improving the Role of Unification Media according to the status of broadcasting in North Korea (북한 방송통신 현황에 따른 통일방송의 역할제고 방안)

  • Park, Eun-Kyung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1173-1180
    • /
    • 2017
  • On July 6, 2017, President Moon Jae - in attended the Hamburg G20 Summit in Hamburg, Germany, and presented the basic directions for North Korea policy through the Korean Peninsula Peace Initiative. In this paper, the Information needs of North Koreans are very strong, and the party Officials also listened to the fact that they listened to the North Korean broadcasting and watched the drama of South Korea. The broadcasting and communication sector aimed at enhancing the role of broadcasting in preparation for reunification in the light of the fact that physical contact can be excluded even in the presence of distrust of the North and the South. Therefore, it describes the cooperation plan through broadcasting against unification.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.

Optical Property of Chermimechanical Pulp Sheet from Fast-Growing Kenaf (Kenaf 반화학펄프로부터 제조한 종이의 광학적 특성)

  • Guo-Min Tan;Nam-Seok Cho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.2
    • /
    • pp.25-35
    • /
    • 1997
  • 오늘날 열대림 면적의 급격한 감소, 지구온난화등 지구환경 보전의 관점에서 이들 목재이외의 자원의 활용 및 양마와 같은 새로운 비목재자원 개발의 중요성이 재인식되기에 이르렀으며, 이 가운데서 양마는 생장이 라르고 수확량이 크며, 목질부의 단섬유는 물론 긴 섬유장을 가진 인피부섬유로 구성되어 있고, 실리카함량도 매우 적어, 특히 산림자원이 부족한 개발도상국에서 펄프.제지용 자원으로서 주목되고 있다. 양마가펄프.제지용자원으로서 오늘날과 같은 세계적 주목을 받게 된 것은 미국 농무성 북부지역연구센타 에서 이루어진 “새로운 섬유작물”에 관한 기초연구에서 양마가 제지용 섬유작물로서 높이 평가되고 있다. 양마의 경우 인피부는 비교적 리그닌함량이 적고, 목질부는 활엽수재에 가까운 리그닌을 함유하고 있는데다, 섬유형태에 있어서도 인피부와 목질부간에 큰 차이가 발견된다. 본 연구에서는 양마를 중성아황산법으로 전처리하여 제조한 반화학펄프로 부터 제조한 종이의 광학적 성질을 검토하였다 펄프의 광학적 성질은 원료의 화학적 조성,섬유의 형태, 부위.화학적 처리정도, 원료의 저장기간 및 충전제의 첨가에 따라 크게 영향을 받았다. 장섬유와 낮은 리그닌함량을 가진 전간부 펄프시트는 불투명도가 낮았으며, 목질부 펄프로부터 상대적으로 밀도가 다소 높고, 불투명도도 높은 종이를 만들 수 있었다. 펄프원료의 저장기간이 백색도를 낮추었으며, 불투명도에는 그다지 영향하지 않았다. 약품전처리 및 표백이 백색도 및 불투명도에 크게 영향하였고, 특히 충전제 첨가로 광산란을 증가시켜 불투명도가 높은 종이를 제조할 수 있었다.6. CL종의 난황콜레스테롤 수준에 대한 계란의 일령 상호간에는 전체적으로 상호간에 차이가 없었다. 7. 26주령시 혈중콜레스테롤 수준은 CL종이 다른 두 육계종들 보다 유의적 (P$\leq$0.05)으로 높았다. 8. 성별간 혈중콜레스테롤 수준의 차이는 CL종, BR1 및 BR2 중에서 CL종에서만 나타났으며, 수컷은 암킷보다 혈액 100 mL당 약 90 mg이 낮았다.구체적인 생화학적인 연구가 이루어져야 될 것으로 여겨진다.야 할 것으로 사료된다. 냉장 저장을 하고 저장기간이 길어질 경우는 냉동저장을 사용하는 것이 바람직하다고 생각된다.S, FOS나 말티톨로 대체된 스폰지 케익은 설탕 100% 사용한 케익과 비교하여 크게 나쁘지 않거나 휠씬 나은 특성을 보이므로 스폰지 케익 제조에 그들의 이용이 가능함을 확인하였다.thione 같은 다른 항산화제의 절약 효과, CYP2El의 유도 저하를 통하는 것으로 생각되며 그중 어떤 것에 가장 큰 영향을 받는 지는 아직 알려지지 않았고 더욱 많은 연구가 요구된다.우와 사료에 $\omega$3계 지방산 급원을 첨가, 동물에게 이행시켜 $\omega$3계 지방산 강화식품을 제조하는 두 가지 방법이 있을 수 있는데 전자는 통조림, 과자, 건강보조식품류에 다용되며 후자는 다양한 기능성 축산식품에 활용되고 있다. $\omega$3계 지방산 강화 축산식품에는 돼지고기, 우유, 치이즈, 계란, 분유, 햄 등 다양한 제품에 활용, 개발되고 있으며 최근에는 이러한 식품 개발에 더욱 박차가

  • PDF

The Study on Bone Mineral Density Measurement Error in Accordance with Change in ROI by Utilizing Dual Energy X-ray Absorptiometry (DEXA를 이용한 골밀도 측정시 검사자의 ROI 변화에 따른 골밀도 측정값의 오차에 관한 연구)

  • Lee, Yun-Hong;Lee, In-Ja;Yong, Hyung-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Dual Energy X-ray Absorptiometry(DEXA) is commonly used to diagnose Osteoporosis. The errors of DEXA bone density operation are caused by operator, bone mineral density meter, blood testing, patient. We focus on operator error then study about how much influence operator's region of intest(ROI) in bone testing result. During from March to July in 2011. 50 patients ware selected respectively from 30, 40, 50, 60, and 70 age groups who came to Korea University Medical Center(KUMC) for their Osteoporosis treatment. A-test was performed with usually ROI and B-test was performed with most widely ROI. Then, We compare A-test and B-test for find maximum difference of T-score error which occurred operator ROI controlling. Standard deviation of T-score of B-test showed 0.1 higher then A-test in femur neck. Standard deviation of B-test showed 0.2 higher then A-test in Ward's area which in Greater trocanter and Inter trocanter. Standard deviation of B-test showed 0,1 lower then A-test in L-1. Bone density testing about Two hundred patients results are as follow. When operator ROI was changed wider than normal ROI, bone density of femur was measured more higher but bone density of L-spine was measured more lower then normal bone density. That means, sometime DEXA bone density testing result is dependent by operator ROI controlling. This is relevant with the patient's medicine and health insurance, thus, tester always keep the size of ROI for to prevent any problem in the patient.

Osteoid Osteoma Around the Hip Joint (고관절 주위에 발생한 유골 골종)

  • Kim, Tai-Seung;Kim, Jong-Heon;Lee, Bong-Gun;Kim, Soon-Myung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.168-174
    • /
    • 2005
  • Purpose: We experienced 8 cases of osteoid osteoma arising around hip joint which had some characteristics that differ from those arising on long bone. we reports the characteristics of osteoid osteoma arising around the hip joint. Materials and Methods: 8 cases of osteoid osteoma were diagnosed during 1985 to 2004 at hanyang university hospital. all cases were comfirmed patholgically. 6 cases were male, 2 cases were female patients. The mean age was 17 years old (ranged from 8 to 29). They occurred in intertrochanteric area (4 cases), subtrochanteric area (2 cases), acetabulum (1 case) and femoral neck (1 case). We used radiologic tools including magnetic resonance image, computed tomography, bone scintigraphy. clinicopathologic test including erythrocyte sedimentation rate and Creactive protein. Results: The patients expressed various symptoms including thigh pain, knee pain, low back pain and radiating pain respectively. 2 patients had experienced operation on knee joint. 3 patients showed limping gait. Aspirin relieved the pain in 3 patients. The difference in circumference was 1cm between both thighs in 2 cases. Conclusion: Patients with osteoid osteoma arising around hip joint which have various symptoms such as severe knee pain and claudication, differ from infectious disease by clinicopathologic test including erythrocyte sedimentation rate and C- reactive protein and had better diagnostic result in computed tomography.

  • PDF