• Title/Summary/Keyword: 전원설비

Search Result 710, Processing Time 0.023 seconds

Active Power Filter Type Uninterruptible Power Supply (UPS) (전력용 능동필터형 무정전 전원장치)

  • 김제홍;최재호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.100-105
    • /
    • 1998
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply (UPS) with the performance of active power filter which compensates the harmonics and reactive power. With only one power stage, it is working simultaneously as the AC/DC rectifier/battery charger and DC/AC inverter to the operation of battery charging or back-up power supplying. Therefore the operation of the proposed system can be divided into the modes, such as the active power filter mode and the battery back-up power mode. And a novel closed-loop control strategy is used to calculate the reference current. The performance of the proposed 5[kVA] system is verified by the simulation and experimental results.

  • PDF

Modeling of Distributed Generation to Calculate Reliability of Customers (수용가의 신뢰도 평가를 위한 분산전원 모델링)

  • Jo, Jong-Man;Bae, In-Su;Shim, Hun;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.70-76
    • /
    • 2005
  • Unlike the large sized generations of transmission system, the distributed generations have complexities in analyzing and determining model. This paper resents an analytical method for the reliability evaluation of distribution system, including the distributed generations. The method using Load Duration Curve model is simpler than the Monte-Carlo Simulation and is more accurate than that using peak load model. The modeling of distributed generation to analysis reliability of customers using LDC is proposed in this paper, and is compared with the MCS method as a result of case studies.

Characteristics Analysis of Power Capacitor with Unbalanced Voltage Operation (불평형 전압 동작시 전력 커패시터 특성 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.64-72
    • /
    • 2008
  • In the three phase four wire system, voltage unbalance caused by the unbalanced load operation, gives rise to current unbalance and de-rates by the increase of machine's loss and eventually enlarges power capacity and besides has a bad effect on power quality. Power capacitor has been used for the power factor correction of inductive load and the voltage stability of power system. And it uses instead of power side for magnetic excitation of induction motor. If voltage unbalance keeps up, it affects on voltage stress at the power capacitor and finally can be caused breakdown. In this paper, we analysed that voltage and current of power capacitor increases by the voltage unbalance factor and its stress is growing more and more.

The Study of Single Phase Source Stability consider for the DSC Cell s Operation Character (DSC Cell의 동작특성을 고려한 단상 전원의 안정화 연구)

  • Park, Sung-June;Park, Hae-Young;Jeon, Jin-An;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1719-1721
    • /
    • 2005
  • 현재 지구 환경 오염에 관한 관심이 증가하면서, 공해가 없는 자연 에너지원에 대한 연구가 많이 진행되고 있다. 그 중에서도 태양전지 분야중 염료감응형 태양전지(DSC)는 Si계 태양전지와 비교하여 낮은 제조비용등 여러 가지 이유로 최근 많은 연구가 진행되고 있다. 따라서 DSC 발전 시스템의 효율 향상이 요구된다. 본 연구에서는 태양전지 분야 중에서 독립적인 발전설비가 필요한 도서 및 산간 지역에 전력을 안정적으로 공급할 수 있는 소형발전용의 설비로 "전압 및 전류의 피드백을 통한 DSC Cell의 독립전원의 안정화"에 관해 연구하였다. DSC Cell측의 DC입력을 받아 Boost Converter로 승압 후 Full Bridge 인버터를 사용하여 단상 220V 60Hz의 상용전원으로 변환하였다. 여기서는 32Bit 마이크로프로세서인 DSP TMS320F2812의 A/D변환기능을 이용하여 Boost Converter의 스위칭과 Full Bridge 인버터의 스위칭을 제어하였다. 특히 TMS320F2812의 RTC(Real Time Clock)를 이용하여 출력전압의 안정성 향상에 주목적을 두었다. 실험결과 출력단에서는 220V 변동범위 0.2% 주파수 60Hz의 상용전원을 얻었으며, 프로그램의 개선을 통하여 출력전압의 변동범위를 감소시켜야 될 것이다.

  • PDF

A Design of Reference Model Following Fuzzy Control System for Boiler-Turbine Equipment (보일러-터빈 설비에 대한 기준모델 추종 퍼지 제어시스템의 설계)

  • 정호성;황창선;황현준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.4
    • /
    • pp.82-91
    • /
    • 1997
  • In this paper, a design method of the boiler-turbine control system in the coal fired power plant is proposed. We need to control electric output and drum pressure and water level in drum to guarantee stable operation and save energy for generating electricity and decrease air pollution in the boiler-turbine system. This boiler-turbine control system is composed of reference model part and model following part. The multivariable boiler-turbine system is separated into 3 SISO(Single Input Single Output) systems applying the concept of relative gain matrix. Each 3 reference models for separated boiler-turbine system are composed of 1st order nominal plant and hysteresis integral control system and they make good dy¬namic response with no overshoot and fast rising time. Each fuzzy controller to follow as close as possible to the response of each reference model is designed. The robustness and the good tracking property can be achieved using 5150 fuzzy controllers when there are modeling errors, disturbances and parameter pertur¬bations. The effectiveness of the proposed design method is verified through simulations.

  • PDF

The Theoretical Analysis for Instability I. M Driven by VVVF Source (가변주파수 전원으로 구동되는 유도전동기의 불안정 현상에 관한 이론적 해석)

  • Baek, Soo-Hyeon;Kim, Yong
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.57-63
    • /
    • 1993
  • In this paper, we study the effects that the variations of machine parameters and frequency of which affect the instability occured in induction motors when operated at low speed or light load, by obtaining the locus of dominant root for the characteristic equation.

  • PDF

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

THE PREVENT10N MttSURE FOR IflECOMMUNICATlON SYSTEM FROM LIGHTNING SURGE (정보통신설비의 뇌서지 보호대책)

  • Lee, Ki-Sik;Kim, Dong-Jin;Kim, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.2-4
    • /
    • 2006
  • 오늘날 사회가 복잡화 다양화 되면서 각종 정보통신기기 네트워크가 거미줄처럼 연결되어 365일 정보를 교환하고 있으며 정보의 실시간 처리 및 전송등으로 업무처리가 이루지는 상황에서 통신설비의 장애는 한 회사의 업무를 정지시키는것은 물론이고 사회 전체가 정지하는 결과를 초래하고 있다. 과거에 비하여 이상기후 등으로 낙뢰 발생빈도는 점차 증가하고 있으며 이로 인한 정보통신기기의 뇌서지로 인한 피해도 같이 증가하고 있다. 뇌서지의 유입경로를 추적하여 보호대책을 실시하고 있는데 주로 전원측이나 통신선로측으로 유입되고 있으며 접지를 통하여 뇌서지가 유입되는 경우도 많이 발생하고 있다. 뇌서지 억제대책으로 절연화, 바이패스화, 등전위화, 전원측에 피뢰기나 서지보호기등을 설치하는 방법을 설치하고 있으나 피서지 유입경로가 어느 한 부분으로 침입하기 보다는 복합적으로 침입하는 경우가 되부분 이므로 피서지 억제대책 또한 복합적인 피서지억제 시스템을 고려하여야 한다.

  • PDF

펌핑 설비내 수격현상 해석

  • 박인동;김상철
    • Journal of the KSME
    • /
    • v.30 no.4
    • /
    • pp.374-381
    • /
    • 1990
  • 수격해석은 최근의 펌핑 설비의 중요한 선결 과제이고 산업계에서도 자주 문제시되고 있으므로 본 글은 직접 전원 차단으로 인한 수격현상 해석을 수행하는 데 도움이 되도록 여러 문헌을 분 석하여 간략히 정리하였고 그 분석으로부터 다음과 같은 결론을 얻었다. (1) 직경이 다른 관, 분기관 및 병열관 등의 경우는 2절에서와 같이 등가치를 계산함으로써 해석을 단순화한다. (2) 수주 분리시 유체 정지시간, 이동거리 및 보급수량은 3절에 따라 산출하며 이는 수격방지장치 용량 결정의 기초자료가 된다. (3) 실제 펌핑 설비에서 수격현상의 발생은 대부분이 예기치 않는 펌프 전원차단시에 기인된다. 이때의 수격현상 해석을 실용선도에 의해 4.1에 따라 관로내 각 지점의 최고 및 최저 압력을 산출한다. (4) 끝으로 기존 참고문헌에 의한 해석은 여러 가지의 어려운 한계가 존재하므로 추후 수격해석 방안으로서는 특정방정식을 이용한 컴퓨터 수치해석 수행되어야 될 것으로 사료된다.

  • PDF

A Study on the Electrical Properties of Parallel Arc (병렬아크의 전기적 특이점에 관한 연구)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.452-455
    • /
    • 2012
  • 전기배선 또는 코드가 가구 등의 무거운 물건에 깔리거나 진동이나 날카로운 모서리 등에 의해 피복이 손상되어 회로의 누설에 의한 경우 먼지 등 오염물질이 쌓여 습기를 포함하면 전기통로가 형성된다. 즉, 트래킹(tracking)현상과 부품의 열화 등에 의한 누설전류가 흘러 발생하는 전기적 조건의 변화 등이 있다. 또한 전기설비가 규격미달이나 노후된 경우, 전기설비를 변경할 경우, 혹은 전기설비가 잘못 사용되거나 기기와 맞지 않을 경우에 화재가 발생할 수 있다. 본 논문에서는 일반적으로 가정에서 사용되는 전원코드에서 충전부에 흡습되어 나타날 수 있는 병렬아크에 의해 전원코드가 열화되어 용융되는 특성을 고찰하였다.

  • PDF