• Title/Summary/Keyword: 전압조정률

Search Result 20, Processing Time 0.026 seconds

Development of Hybrid AVR for Alternator (교류 발전기용 하이브리드 자동 전압 조정기 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.182-188
    • /
    • 2015
  • An analog AVR has an advantage of short time constant, time to revert again from the abnormal state to a stable one depending on the voltage fluctuations of the load. But the Analog AVR has a disadvantage of large voltage variation according to the load fluctuation. Voltage regulation for digital AVR is very stable, but the time constant is very long compared to that of an analog AVR. Therefore, it indicates that the digital AVR shows unstable output performance in a very large load variations. In this paper, a mixed form of an analog AVR and a digital AVR is proposed. An implemented hybrid AVR has fast time constant and stable voltage regulation capability. Hybrid AVR voltage variations in the load is stable within 1[%] and the voltage stability is also improved. It also showed fast time constant to the level of the analog AVR. Thus hybrid AVR developed in this paper can be used as a power supply for a variety of uses in industry.

Low Power EccEDF Algorithm for Real-Time Operating Systems (실시간 운영체제를 위한 저전력 EccEDF 알고리듬)

  • Lee, Min-Seok;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • For battery based real-time embedded systems, high performance to meet their real-time constraints and energy efficiency to extend battery life are both essential. Real-Time Dynamic Voltage Scaling (RT-DVS) has been a key technique to satisfy both requirements. In this paper, we present an efficient RT-DVS algorithm called EccEDF that is designed based on ccEDF. The proposed algorithm can precisely calculate the maximum unused utilization with consideration of the elapsed time while keeping the structural simplicity of ccEDF, which overlooked the time needed to run the task in calculating the available slack. The maximum unused utilization can be calculated by dividing remaining execution time($C_i-cc_i$) by remaining time($P_i-E_i$) on completion of the task and it is proved using Fluid scheduling model. We also show that the algorithm outperforms ccEDF in practical applications which is modelled using a PXA250 and a 0.28V-to-1.2V wide-operating-range IA-32 processor model.

산업용 고속.고정도 서보/스핀들 드라이브 기술의 최근 동향과 향후 발전전망

  • 최종률
    • 전기의세계
    • /
    • v.45 no.1
    • /
    • pp.28-32
    • /
    • 1996
  • 드라이브 기술의 최신동향 및 향후 전망에 대해 앞으로 전개될 항목을 간략히 요약하면 다음과 같다. 1. 모듈화 및 소형화 2. 직류 전압원의 고전압화 3. 드라이브와 NC간의 간편한 연결 4. NC의 조작화면을 통한 손쉬운 파라미터 조정 5. 디지탈 폐루프 제어 채용(FULL 디지탈화) 6. 에너지 절감형 모델 개발 7. 사용자 편의 기능의 확대 서보/스핀들 드라이브 설계기술의 최신동향 및 향후 개발 전망에 대해서 특징, 기능을 중심으로 이상과 같이 간략하게 설명하였다. 본고가 드라이브 기술 개발에 힘쓰는 관련 engineer들에게 조금이나마 참고가 되길 기대한다.

  • PDF

Development of DC Microgrid Management System Based on Intelligent Agent Systems (지능형 에이전트 기반의 직류 마이크로그리드 관리시스템 개발)

  • Chio, Min-Seok;Hai, Trinh Phi;Cho, Hector;Chung, Il-Yop;Kim, Ju-Yong;Cho, Jin-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.517-518
    • /
    • 2015
  • 본 논문에서는 저압 직류(LVDC) 마이크로그리드(Microgrid)의 배전가능거리와 분산전원 수용률을 증대하기 위한 지능형 에이전트 기반의 전압 제어 기법에 대해서 설명한다. 제안하는 방법은 분산전원에 설치된 지능형 제어노드에서 자율적인 전압, 전류, 전력측정을 수행하고 이러한 데이터를 바탕으로 전압제어 민감도를 산출하며 실시간 모니터링 데이터와 함께 중앙 관리시스템으로 전송된다. 중앙 관리시스템은 교류계통과 연계되는 주(Main) AC-DC 전력변환기와 각 분산 전원과의 협조제어를 통해 마이크로그리드의 전압을 실시간으로 제어한다. 제안하는 전압제어 원리의 구현을 위해 본 논문은 지능형 에이전트 기반의 직류 마이크로그리드 관리시스템에 대해서 설명한다. 개발된 마이크로그리드 관리시스템은 실시간 OS를 탑재한 범용 임베디드 시스템 하드웨어로 구성되며 이더넷 통신을 이용하여 멀티-에이전트 네트워크를 구성한다.

  • PDF

Dynamical Electrical Impedance Tomography Based on the Regularized Extended Kalman Filter (조정 확장 칼만 필터를 이용한 동적 전기 임피던스 단층촬영법)

  • Kim, Kyung-Youn;Kim, Bong-Seok;Kang, Suk-In;Kim, Min-Chan;Lee, Jung-Hoon;Lee, Yoon-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.23-32
    • /
    • 2001
  • Electrical impedance tomography (EIT) is a relatively new imaging modality in which the resistivity (conductivity) distribution of the unknown object is estimated based on the known sets of injected currents and measured voltages on the surface of the object. In this paper, we propose a dynamical EIT reconstruction algorithm based on the regularized extended Kalman filter(EKF). The EIT inverse problem is formulated as dynamic equation which consists of the slate equation and the observation equation, and the unknown state(resistivity) is estimated recursively with the aid of the EKF. In doing so, the generalized Tikhonov regularization technique is employed in the cost functional to mitigate the ill-posedness characteristics of the inverse problem. Computer simulations for the 16-channel synthetic data are provided to illustrate the reconstruction performance of the proposed algorithm.

  • PDF

Resistivity Image Reconstruction Using Interacting Dual-Mode Regularization (상호작용 이중-모드 조정방법을 이용한 저항률 영상 복원)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.152-162
    • /
    • 2016
  • Electrical resistivity tomography (ERT) is a technique to reconstruct the internal resistivity distribution using the measured voltages on the surface electrodes. ERT inverse problem suffers from ill-posedness nature, so regularization methods are used to mitigate ill-posedness. The reconstruction performance varies depending on the type of regularization method. In this paper, an interacting dual-mode regularization method is proposed with two different regularization methods, L1-norm regularization and total variation (TV) regularization, to achieve robust reconstruction performance. The interacting dual-mode regularization method selects the suitable regularization method and combines the regularization methods based on computed mode probabilities depending on the actual conditions. The proposed method is tested with numerical simulations and the results demonstrate an improved reconstruction performance.

C00rdinated Testing between transformer Tap Selection and Inverter Voilage Control in the PV Distributed Generation system (태양광 분산 발전 시스템의 계통연계용 변압기탭 선정과 인버터전압조정 협조시험)

  • Yoon, kap koo;CHO, SeongSoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1098-1099
    • /
    • 2015
  • ${\bullet}$ 시험대상: 영월태양광 4,990kW(998kW ${\times}$ 5호) ${\bullet}$ 13.07.31 연계기술검토의뢰 ${\bullet}$ 13.08.28 한전검토결과: 인근변전소 영월S/S(40MW) 초과로 10.8km 지점의 평창 D/L 평창간 347호 주진S/S에 다음의 보완대책과 연계 권고 ${\cdot}$ 문제점: 적정전압이탈 및 순시전압변동률 유지불가 ${\cdot}$ 연계기준만족을 위해 한전에서 제시한 보완대책 : 계통용량증설(설비보강), 연계용량 감소 및 전용선로 연계 ${\bullet}$ 14.01.09 분산형설치자의 용역사(에이스기술단)에서 송배전용전기설비 이용규정과 연계기준 만족을 위한 보완대책 제안 ${\cdot}$ 태양광발전시스템 인버터 자동전압(역률/무효전력) 조정기능 및 감시설비 구비 ${\cdot}$ 최적 공통연결점 선정: 분산형전원으로 부터 전기적으로 가장 가까운 영월D/L 영월S/S측에 개폐장치설치 하고 주진S/S 측으로 연계 ${\bullet}$ 14.01.29~06.19 한전(전력연구원)의 유효성 검토 ${\cdot}$ 보완대책 기술적 유효(실증시험 시행 후 시행공문 발송 예정) ${\bullet}$ 14.08.08 송배전용전기설비 이용규정 개정에 따른 협의 ${\cdot}$ 변압기 대당 20MW에서 25MW ${\cdot}$ 변전소 전체 60MW에서 75MW까지 허용 ${\cdot}$ 영월 S/S 측 문곡/영월 D/L 연계 공사 협의 ${\bullet}$ 14.10.04 사용전검사, 한전계통연계운전 시작 ${\bullet}$ 인버터 고정역률(99.9~100%) 운전 시험 ${\cdot}$ 14.11.21 22.9kV 계전기(SEL-751) 5대, 15분 간격 자료저장 ${\cdot}$ SEL-751/USB to RS232C/노트북 15분간격 측정(첨부) ${\bullet}$ 14.03.07 인버터 역률 95.0% 조정 15분간격 측정(첨부) ${\bullet}$ 변압기탭 선정과 인버터전압조정협조시험 계획 ${\cdot}$ 변압기탭을 현장에서 상하 1탭씩 변경 ${\cdot}$ 인버터역률을 인버터공급사에서 원격조정 ${\cdot}$ 22.9kV 보호계전기 SEL-751, 15분 간격 측정 ${\cdot}$ 인버터 370V 계전기 K-PAM DG3000/현장감시설비 연계 ${\cdot}$ 15분 간격 측정 저장 ${\cdot}$ 현장감시설비/인터넷 연결 원격측정(첨부예정)

  • PDF

High Efficiency and High Power-Factor Power Supply for LED Lighting Equipment (고효율 고역률 LED 조명장치용 전원공급장치)

  • Jeong, Gang-Youl
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.23-34
    • /
    • 2018
  • This paper presents the high efficiency and high power-factor power supply for LED lighting equipment. The proposed power supply is the single-stage power structure consisted of the full-bridge diode rectifier and flyback converter, and thus the power-factor correction and output voltage regulation are performed simultaneously using only one controller IC and one power semiconductor switch. Furthermore, the proposed power supply reduces the voltage stress and switching loss of main switch using the regenerative snubber, and it improves the system efficiency using the synchronous rectifier. The applied synchronous rectifier is the new voltage-driven type and its operation and construction are simple. In this paper, the operation principle of proposed power supply is explained through the operation analyses of its power-factor correction and main power conversion parts and the operation of synchronous rectifier is described, briefly. Also, a design example of the power circuit of 40W-class prototype is shown and the operation characteristics of proposed power supply are validated through the experimental results of the implemented prototype by the designed circuit parameter.

A Study on the Variable Hysteresis Current Mode Control Method for Power Factor Improvement of the Single Phase Boost Converter (단상 부스터 콘버터의 입력역률 개선을 위한 가변 밴드폭 제어방식에 관한 연구)

  • 김철우;권순재;유동욱;박성준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.36-43
    • /
    • 1994
  • Many new electronic products are required to have a near unity power factor and a distortion free current input waveform. In this paper, single phase AC to DC Boost-Converter which is controlled with continuous conduction mode(CCM) is analyzed. Each parameter is determined for variable hysteresis current mode and real time simulation results showed high power factor possible. l(kW] boost converter was designed and constructed accordingly. Experimental results to load and parameter variations are well similar to the simulation results.

  • PDF

Regularized Modified Newton-Raphson Algorithm for Electrical Impedance Tomography Based on the Exponentially Weighted Least Square Criterion (전기 임피던스 단층촬영을 위한 지수적으로 가중된 최소자승법을 이용한 수정된 조정 Newton-Raphson 알고리즘)

  • Kim, Kyung-Youn;Kim, Bong-Seok
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.249-256
    • /
    • 2000
  • In EIT(electrical impedance tomography), the internal resistivity(or conductivity) distribution of the unknown object is estimated using the boundary voltage data induced by different current patterns using various reconstruction algorithms. In this paper, we present a regularized modified Newton-Raphson(mNR) scheme which employs additional a priori information in the cost functional as soft constraint and the weighting matrices in the cost functional are selected based on the exponentially weighted least square criterion. The computer simulation for the 32 channels synthetic data shows that the reconstruction performance of the proposed scheme is improved compared to that of the conventional regularized mNR at the expense of slightly increased computational burden.

  • PDF