• Title/Summary/Keyword: 전압방전

Search Result 1,024, Processing Time 0.043 seconds

Discharge characteristics of Flat Fluorescent Lamp (FFL(Flat Fluorescent Lamp)의 방전 특정)

  • Kwon, Soon-Seok;Ryu, Jang-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.44 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • This experiment was analysed the discharge characteristics of FFL(flat fluorescent lamp). FFL is operated by sine and pulse wave source. We use FFL which has the electrodes covered with dielectric, observed the discharge characteristics of FFL by V-Q Lissajous' figure. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. When the duty ratio increases, the number of metastable xenon atoms seem to increase. Consequently, the 172nm radiation becomes strong as the duty ratio increases.

A study on the discharge characteristics by gas pressure and discharge gap in Xe absolute partial pressure of AC PDP (Xe 절대분압에서 가스 압력과 전극 간격에 따른 AC PDP의 방전 특성 고찰)

  • Kim, Dong-Hwan;Cho, Hyun-Min;Ha, Chang-Seung;Ok, Jung-Woo;Cho, Sung-Yong;Kim, Dong-Hyun;Lee, Hea-June;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1360_1361
    • /
    • 2009
  • 일반적으로 AC PDP는 Xe+Ne이 동작가스로 사용된다. 본 연구에서는 Xe 분압을 50, 60, 80, 100 Torr로 고정한 상태에서 전체 가스압력을 변화시키고 Short 방전 갭으로 $80{\mu}m$를, Long 방전 갭으로 $180{\mu}m$ 적용함으로써 나타나는 AC-PDP의 방전특성을 분석하였다. 여기에 Xe 분압을 Short 방전 갭에서는 80, 100 Torr로, Long 방전 갭에서는 50, 60, 80 Torr로 각각 고정하고, Ne 압력을 변화시킴에 따라 나타나는 방전개시전압, 소비전력, 휘도, 발광효율을 측정하여 높은 휘도와 효율을 가지면서 방전개시전압을 최대한 낮출 수 있는 적정 조합을 연구하였다. 실험결과, Short 방전 갭 패널은 소비전력이 26% 낮았고, Long 방전 갭 패널은 휘도가 45% 높았다. 휘도, 소비전력 등 여러 가지 측면을 고려하였을 때, 방전개시전압이 가장 낮은 Short 방전 갭, Xe 절대분압 80 Torr, Xe 35%(Xe+Ne=286 Torr)에서의 방전 특성이 가장 우수하였다.

  • PDF

A test result of dynamic character about low voltage electric machine under voltage sags (순간전압강하에 대한 저압기기의 응동특성 실험결과)

  • Lee, Geun-Joon;Lee, Hyun-Chul;Jeong, Sung-Won;Gim, Jea-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.40-42
    • /
    • 2007
  • 본 논문은 전기기기에 순간전압저하를 발생 하였을 경우 응동특성에 대한 영향을 계측하였다. 실험 방법은 AVR에서 Sag 발생기인 IPC에 입력한 후, IPC에서 전압의 크기와 시간을 조정하여 실험기기에 순간전압 강하를 발생하였다 실험기기는 PLC, 전자접촉기, 400[W]고압방전램프를 시험하였다. PLC시험에서 무부하와 정격부하에 따라 특성 의 변화가 생겼으며, 정격부하에서 Voltage Sag의 영향을 더 받았다 전자접촉기의 시험은 위상을 $0^{\circ},\;30^{\circ},\;60^{\circ},\;90^{\circ}$로 변화하여 Voltage Sag 발생시켜 계측하였으며, 위상의 변화에 따라 특성곡선이 변화하였다. 고압방전램프시험은 고압나트륨램프와 수은램프, 메탈헬라이드에 Voltage Sag를 발생시켰다. 방전램프의 시험결과 고압나트륨램프의 특성곡선이 가장 안정적으로 나타났다. 본 실험을 통해 순간전압저하에 대한 저압기기의 특성을 실험적으로 입증하여 전력시스템의 설계에 영향을 미칠 것이라 기대된다.

  • PDF

Discharge Characteristics of the MFFL between High Voltage Source and Low Voltage Source using the Transformer (전원 전압 및 변압기 권선비에 따른 면광원의 방전특성 분석)

  • Kim, W.S.;Back, J.B.;Park, J.H.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.77-79
    • /
    • 2008
  • 본 논문에서는 구동전압 인가 방식에 따른 면광원의 방전특성에 대해 분석한다. 2kV이상의 고전압 전원장치의 직접 이용은 구성 소자의 전압 스트레스를 증가시키며 가격 상승의 원인이 된다. 100~400V대의 전원장치에 변압기를 적용하여 구동전압을 인가하게 되면 전원 및 구동회로의 간략화를 도모할 수 있으나 변압기의 영향으로 인한 천이 지연시간, 파형왜곡의 영향으로 방전 불안정 및 광효율 저하를 야기할 수 있다. 전원 출력전압 및 변압기의 권선비에 따른 직접구동과의 비교연구를 통하여 최적 설계 방안을 도모한다.

  • PDF

Comparison of Cell-to-Cell Voltage Imbalance of High-Power Serial Battery Pack with Variability of C-rate (C-rate의 가변성에 따른 고출력 직렬 배터리팩의 셀 간 전압 불균형 비교분석)

  • Kim, Seung-Woo;Lee, Pyeong-Yeon;Han, Dong-Ho;Park, Jin-Hyeong;Kim, Woo-yong;Kim, Jong-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.125-126
    • /
    • 2018
  • 본 논문에서는 원통형 NCA 리튬이온 배터리로 제작된 고출력 직렬조합 배터리팩으로 C-rate에 따른 전기적 특성 실험을 수행하였다. 방전 용량 프로파일 실험을 통해 배터리팩의 충/방전 C-rate가 배터리팩의 내부 파라미터에 어떠한 영향을 주는지 비교 분석한다. 실험을 통해 방전 용량과 전압 편차 파라미터를 측정한다. 전압 편차 그래프는 만방 구간과 만방 이후 휴지 구간의 셀 간 전압 편차를 중심으로 관찰하며 두 구간의 전압 편차를 비교한다. 3가지 파라미터를 비교하여 가장 효율적인 C-rate를 알아보았다.

  • PDF

Modified Driving Method for Reducing Address Time During Subfield Time in AC PDP (플라즈마 디스플레이 패널에서 부화면 시간동안 기입시간을 단축시키기 위한 수정된 구동파형)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.135-139
    • /
    • 2015
  • The address discharge time lags are investigated in each subfield time in AC plasma display panel and a modified driving waveform is proposed to reduce the address discharge time lag by applying different additional scan voltage under no misfiring discharge production. The weak plasma discharge in AC PDP is generated by applying high positive-going ramp waveform to the scan electrode during the first reset period and that induce the production of the priming particle and wall charge. Because the wall charge becomes the wall voltage in a cell, the wall plus external address voltage produce the address discharge. However, as the wall charge in a cell is gradually disappeared as time passed, the address discharge time in the subfield time for 1 TV frame is lagged. In the first subfield time, the address discharge is faster produced than the other subfield time because the wall charge are much remained by the high positive-going ramp voltage during the reset period in the first subfield time. Meanwhile, from the second to last subfield, the address discharge production time is gradually delayed due to the dissipation of the wall charge in a cell. In this study, the address discharge time lags are measured in each subfield time and the total address discharge time lags are shortened by applying the different additional scan voltage during the address period in each the subfield time.

Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs (ADN Gate PDP의 DC 방전셀 방전특성 최적화)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.34-39
    • /
    • 2004
  • This research investigated the influence on the 4 cell of DC discharge on the side of the discharge characteristic. This DC discharge cells are that composes AND gate of AND gate PDP newly proposed. As for the discharge starting voltage of this discharge cell of 4 pieces, it has been understood that there is deeply a relation up to the space charge generated from the discharge of adjoining discharge cell through the experiment. The discharge voltages which had become each discharge cell optimizations from the experiment result were decided. Moreover, the width of the margin of two AND input voltages is wide and the AND function occurs clearly. However, it has been qualitatively understood that it is difficult enough to obtain the operation margin of the DC priming discharge used to address discharge of PDP.

유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과

  • Yu, Yeong-Hyo;Kim, Seong-Hui;Park, Gyeong-Sun;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.519-519
    • /
    • 2013
  • 본 연구에서는, 전기적 충격이 없고 넓은 면적을 동시에 처리할 수 있는 형태의 유전체 장벽 방전(DBD: Dielectric Barrier Discharge)을 이용한 대기압 저온 플라즈마 장치를 제작하고 이를 이용하여 빵 곰팡이(Neurospora crassa) 살균에 대한 기본 분석을 하였다. 실험에 사용한 저온 대기압 면방전 플라즈마의 파워는 사인파 교류전압을 인가하여, 방전전압은 1.4~2.3 kV, 방전전류는 20~30 mA의 값을 가지며, 전압과 전류의 위상차는 약 80도의 기울기 차이가 난다. 이때의 출력은 약 4 W를 가지며, 공랭식 쿨러를 이용하여 유전체의 열을 배출하였다. 시료대의 온도 측정결과 방전과 동시에 쿨러를 작동할 경우 최대 10분에서 37도를 넘지 않았다. 장치에서 발생하는 플라즈마에 의한 O3의 양은 플라즈마 발생부로부터 10 mm 이내에서 약 25~30 ppm 이 측정되었으며, NO나 NO2 는 거의 검지되지 않았다. 증류수(Deionized water)속에 담긴 빵 곰팡이(Neurospora crassa) 포자를 면방전 플라즈마 발생장치로 처리하였을 때, 포자의 발아율은 처리시간 및 출력파워가 증가함에 따라 급격히 감소하였으나 VM (Vogel's Minimal) 배양액에 넣고 플라즈마 처리를 한 경우에는, 증류수의 결과와 달리 살균효과가 미비함을 보였다. MTT 측정법 또한 같은 경향성을 보였으며, 이를 통해 포자를 둘러싸고 있는 환경이 플라즈마의 살균효과에 영향을 미치는 것으로 보인다. 본 실험을 통해, 유전체 장벽을 이용한 면방전 플라즈마 발생장치가 플라즈마 제트(jet)와 달리 직접적인 플라즈마 접촉 없이도 미생물 살균이 가능하다는 것을 보았으며, 처리대상의 생체용액과 같은 주변 환경에 영향을 받음을 알 수 있었다. 또한 면방전 플라즈마 장치로부터 발생하는 O3과 같은 활성종들이 빵 곰팡이의 비활성화에도 역할을 할 수 있음을 알 수 있었다.

  • PDF

The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage (3상 전압을 사용한 중첩방전형 오존발생기의 오존생성 및 방전잡음특성)

  • 전병준;송현직;김영훈;최상태;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2000
  • In this paper, an ozonizer, which can supply individual and superposed silent discharge using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes(Central Electrode, Internal Electrode and External Electrode and External electrode) and 2 gaps (gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the flow rate of supplied gas (O2). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum value was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.

  • PDF

고전압 펄스 시스템 '천둥'을 이용한 N2, SF6 혼합기체에서의 전기.광학적 분석

  • Byeon, Yong-Seong;Song, Gi-Baek;Hong, Yeong-Jun;Lee, Seung-Hui;Eom, Hwan-Seop;Choe, Deok-In;Ryu, Han-Yong;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.221-221
    • /
    • 2011
  • 수 Tera Watt급의 가속기 및 펄스파워 시스템은 다수의 스위치를 사용하고 있으며, 이와 같은 가속기 및 시스템의 성능은 기체방전 스위치의 성능에 직접적으로 관련되어 있다. 일반적으로 이와 같은 기체방전, 액체방전 고출력 스위치는 다목적으로 많은 연구와 개발에 응용되고 있다. 예를 들어 천둥 펄스전자빔 발생장치는 12개의 Marx gap 및 3개의 100 kV 펄스충전 전기트리거 gap을 가지고 있다. 기체 방전 또는 액체 방전 펄스 충전 갭 스위치의 음극에 펄스 고전압이 인가되면 이로 인하여 음극에서 전자빔이 발생한다. 내부에는 전자빔이 양극과 충돌하는 순간 양극표면에 플라스마가 형성된다. 이와 같은 플라스마 sheath는 축 방향 이극관 안에서 양극 충전 에서 음극으로 팽창하면서 전파하며, 또한 거의 동시에 음극표면에도 플라스마가 형성되어 음극에서 양극으로도 팽창하여 전파하게 된다. 이와 같은 펄스충전 고출력 갭 스위치 안에서 발생되는 방전 플라스마의 특성에 관한 갭 breakdown 과정에 대한 특성연구를 한다. 고출력 스위치의 특성 조건으로는 방전전압, 방전시간, jitter 등이 있다. 본 연구에서는 최대전압 600 KV, 최대전류 88 KA, 펄스 폭 60 ns의 특성을 가지는 고전압 펄스 시스템 '천둥'을 이용하여 방전 챔버에 고전압 펄스를 인가하고 N2와 SF6 혼합기체 종류와 압력에 따른 현상을 전기, 광학적으로 연구하였다. 전극은 구리텅스텐 합금재질의 표준전극을 사용하였고, 전극 간격은 20 mm로 고정하였다. 방전 챔버 압력을 100 torr에서 4 기압까지 변화시켜가며 실험을 진행하였고, N2에 대한 SF6의 혼합비율을 0%~100%까지 변화시키며 실험을 진행하였다. 실험결과 방전전압은 압력이 증가함에 따라 증가하다가 2 기압 이상에서는 완만히 증가하는 경향을 보였고, SF6 혼합비율은 0~10%까지 급격히 증가하고, 그 이상의 혼합비율에서는 완만히 증가하였다. 전자온도는 SF6 혼합비율이 0~10%일 때 급격히 증가하여 이후에는 포화되는 경향을 보였고, 압력에 따라서는 큰 경향성을 보이지 않았다.

  • PDF