• Title/Summary/Keyword: 전신체형

Search Result 19, Processing Time 0.022 seconds

3D Clothes Modeling of Virtual Human for Metaverse (메타버스를 위한 가상 휴먼의 3차원 의상 모델링)

  • Kim, Hyun Woo;Kim, Dong Eon;Kim, Yujin;Park, In Kyu
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.638-653
    • /
    • 2022
  • In this paper, we propose the new method of creating 3D virtual-human reflecting the pattern of clothes worn by the person in the high-resolution whole body front image and the body shape data about the person. To get the pattern of clothes, we proceed Instance Segmentation and clothes parsing using Cascade Mask R-CNN. After, we use Pix2Pix to blur the boundaries and estimate the background color and can get UV-Map of 3D clothes mesh proceeding UV-Map base warping. Also, we get the body shape data using SMPL-X and deform the original clothes and body mesh. With UV-Map of clothes and deformed clothes and body mesh, user finally can see the animation of 3D virtual-human reflecting user's appearance by rendering with the state-of-the game engine, i.e. Unreal Engine.

Classification and Analysis of the Somatotype through Side View Silhouette of the whole body by Multivariate Method (다변량분석법에 의한 측면전신체형 분류)

  • 권숙희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1227-1235
    • /
    • 1997
  • The purpose of this study was to classify the somatotype based on the side view and to analyze the characteristics of each somatotype. In order to reduce the burden of stocks and increase clothing fitness, systematic information on typical body sizes and somatotypes is essential. The subjects were 206 unmarried women aged from 19-29. Data were collected through anthropometry and photometry and analyzed by factor analysis, cluster analysis and analysis of variance. As the result of factor analysis for the classification of somatotypes, 8 factors which explain 74.7% of variance were extracted from 35 photometric and 17 anthrometric data. Using factor scores cluster analysis was carried out and the subjects were classified into 4 cluster.Each cluster was classified as bending type, swayback, turning over type and straight type accordding to its position to the relativeplumb line and their side view contour.

  • PDF

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Development of a Noble Dosimetry Using Metaphase Analysis and Micronuclei Assay of Bone Marrow Cells in Mice (마우스 골수세포의 중기염색체 분석 및 미소핵 검사를 이용한 피폭선량 평가법의 개발)

  • Min, Jung-Jun;Bom, Hee-Seung;Kim, Young-Ho;Yoon, Hyun-Joong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.74-81
    • /
    • 2000
  • Purpose: The purpose of this study was to develop in vivo dosimetries using both chromosomal aberrations and micronuclei in mice to assess biological effects of radiations. Materials and Methods: Five each mice were irradiated with 0, 1, 2, 3, 4, 5, 10 Gy of Cs-137 gamma-rays. We scored numbers of chromosomal aberrations in metaphase spreads and numbers of micronuclei in bone marrow smears under light microscope, and obtained the dose-response relationships. We also examined the relationship between the two dose-response curves. Results: The frequency of both chromosomal aberrations and micronuclei increased with dose, in a linear-quadratic manner The delta, beta, and alpha coefficients were 0.0176, 0.0324, and 0.0567 for metaphase analysis (r=1.0, p<0.001) and 0.0019, 0.0073, and 0.0506 for micronuclei assay (r=1.0, p<0.001). The frequency of chromosomal aberrations and micronuclei in different radiation doses was significantly correlated (r=0.99, p<0.01). Conclusion: In vivo dosimetry using either metaphase analysis or micronucleus assay was feasible in mice. These methods could be useful to evaluate biological effects of radiation.

  • PDF

Development of a Korean Adult Female Voxel Phantom, VKH-Woman, Based on Serially Sectioned Color Slice Images (고해상도 연속절단면 컬러해부영상을 이용한 한국인 성인여성 복셀팬텀 VKH-Woman 개발)

  • Jeong, Jong Hwi;Yeom, Yoen Soo;Han, Min Cheol;Kim, Chan Hyeong;Ham, Bo Kyoung;Hwang, Sung Bae;Kim, Seong Hoon;Lee, Dong-Myung
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.199-208
    • /
    • 2012
  • The computational human phantom including major radiation sensitive organs at risk (OARs) can be used in the field of radiotherapy, such as the variation of secondary cancer risks caused by the radiation therapy and the effective dose evaluation in diagnostic radiology. The present study developed a Korean adult female voxel phantom, VKH-Woman, based on serially sectioned color slice images of Korean female cadaver. The height and weight of the developed female voxel phantom are 160 cm and 52.72 kg, respectively that are virtually close to those of reference Korean female (161 cm and 54 kg). The female phantom consists of a total of 39 organs, including 27 organs recommended in the ICRP 103 publication for the effective dose calculations. The female phantom composes of $261{\times}109{\times}825$ voxels (=23,470,425 voxels) and the voxel resolution is $1.976{\times}1.976{\times}2.0619mm^3$ in the x, y, and z directions. The VHK-Woman is provided as both ASCII and Binary data formats to be conveniently implemented in Monte Carlo codes.

Morphological Characteristics and Growth Performance of Korean Native Black Goats (재래흑염소의 형태적 특징 및 생육특성)

  • Lee, Sang-Hoon;Lee, Jinwook;Jeon, Dayeon;Kim, Seungchang;Kim, Kwan-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.149-155
    • /
    • 2019
  • This study aims to provide basic data for investigating the phenotypic traits and growth characteristics of Korean native black goats. The Jangsu and Tongyoung strains were shown to have black hair, while the Dangjin strain was shown to have black or dark brown long hair. Only the Tongyeong strain was found to have no wattle and one goat each from the females and males of the Dangjin strain was found to have no horns. The lengths of the ears and tails were similar for the female and male goats, while the lengths of horns and beards were longer in the male goats. The birth weight was 2 kg on average, with that of male goats tending to be slightly heavier than that of the females. Weights at the weaning period were found to be slightly heavier for the males. Also, at 12 months, the weights of the male goats by strain were shown to be heavier than that of the females. The body length and depth by strain were found to be higher for the male goats, while no differences in the chest width and girth between the strains or gender were found. These findings are expected to be used as a basis for differentiating between native and crossbred Korean black goat strains and for improving Korean native black goats.

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

Sasang Constitution Classification related to an aspect of distribution GCM(General Coordinative Manipulation) Body Type and Experimental Study based on the character of Static Posture and Dynamic Hyper/Hypo-mobility Pattern (사상의학의 4체질 분류에 따른 각 체질별 전신조정술 체형분포 양상과 그에 따른 정적 자세특성 및 동적 운동증감 양상에 관한 실증적 연구)

  • Moon, Sang-Eon;Joe, Hyun-Rae;Oh, Chang-Sun;Kim, Sung-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.505-517
    • /
    • 2005
  • The Purposes of this study were to find complementary connectible new factors that analyzed correlation relate of Sasang Constitution and GCM Body Type in Static Posture and Dynamic Hyper/Hypo-mobility Pattern. Method of this study was asymtomatic volunteers 232(unmarried man and women), conducted from September 1 to December 31. In this main study progressing step diagnosised first, Constitution of Sasang medicine after being classified into four groups of Soyangin, Taeumin, Soeumin, Taeyangin diagnosis of GCM Body Type and progressed that related Static Posture and Dynamic Hyper/Hypo mobility Pattern. The results are as follows. Distribution of Sasang Medicine Constitution proved to be Taeyangin 13, Soyangin 66, Taeumin 67, Soeumin 86 respectively. Distribution of GCM Body Type proved I Body Type 72(31.0%), II Body Type 54(23.3%), III Body Type 89(38.4%), IV Body Type 17(7.3%). The distribution of Sasang Constitution according to GCM Body Type was that; I Body Type was distributed in the order Soeumin 34.7%(25), Taeumin 31.9%(23), Soyangin 30.6%(22), Soeumin 34.7%(25) is the most people. II Body Type was distribution of in the order Soeumin 42.6%(23), Soyangin 5.9%(14), Taeumin 24.1%(13), Soeumin 42.6%(23) is the most people. III Body Type was distribution of in the order Soeumin 37.1%(33), Taeumin 30.3%(27), Soyangin 28.1%(25), Soeumin 37.1% is the most people. IV Body Type proved high distribution each of Soeumin 29.4%(5) and Soyangin 29.4%(5). In case of main left side posture character of spine and limbs about I Body Type 72 persons with left scapular and ilium forward tilted pattern proved in the order high distribution iliac crest thigh and scapular high 70(97.2%), gluteal fold high and scapular abduction 69(95.8%), lumbar scoliosis 65(90.3%). Also, in case of right side posture character proved in the order high distribution deep gluteal fold 69(95.8%), umbilical deviation 68(94.4%). Incase of main left side posture character of spine and limbs about n Body Type 54 persons proved in the: order high distribution knee hyperextension 50(92.6%), shoulder deviation 49(90.7%) etc. Also, in case of right side posture character proved in the order high distribution pelvic deviation 53(98.1%), iliac crest thigh 52(96.3%), hip flexion and ankle inversion 51(94.4%) etc. In case of main left side posture character of spine and limbs about III Body Type 89 persons proved in the order high distribution shoulder deviation 87(97.8%), scapular abduction 86(96.6%), scapular high 85(95.5%) etc. And in case of right side posture character proved in the order high distribution pelvic deviation and iliac crest thigh 86(96.6%) etc. In case of main left side posture character of spine and limbs about IV Body Type 17 persons proved in the order high distribution pelvic deviation, lumbar sciliosis and lumbar lordosis increase 15(88.2%) etc. Also, in case of right side posture character proved in the order high distribution wrist dorsiflexion 16(94.1%), thickened achilles tendon etc.

  • PDF

Synthesis of $[^{51}Cr]Cr(III)$-EDTA Complex and Measurement of Glomerular Filtration Rate br Radioactivity Counting of Head and Neck Region ($[^{51}Cr]Cr(III)$-EDTA 착물 합성 및 $[^{51}Cr]Cr(III)$-EDTA 주사후 두경부 방사능 계측에 의한 사구체 여과율 측정)

  • Yang, Seung-Dae;Lim, Sang-Moo;Chun, Kwon-Soo;Suh, Yong-Sup;Yoon, Yong-Ki;Park, Hyun;Woo, Kwang-Sun;Chung, Wi-Sup;Oh, Ok-Doo;Lee, Jung-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.364-370
    • /
    • 1994
  • The purpose of this study is to evaluate the clinical application of the no carrier added $[^{51}Cr]Cr(III)$-EDTA complexes, produced at Korea Cancer Center Hospital. The $[^{51}Cr]Cr(III)$-EDTA complexes, usefut for measurement of GFR were prepared at room temperature in the presence of bicarbonate catalysts. The radiochemical purity of $[^{51}Cr]Cr(III)$-EDTA was over 99% by paper electrophoresis. The time activity curves were obtained by counting the blood samples from 5 volunteers and counting the head and neck regions with whole body counter after injection of the $^{51}Cr$-EDTA, respectively. After the nonlinear regression, the area under curve was obtained. The plasma clearance of the $^{51}Cr$-EDTA was calculated with injected dose/AUC. The clearance rate calculated with the head and neck counting data was in good agreement with the result from the plasma sample radioactivity at 1-3 hrs after injection. From this result, the counting of head and neck region and the nonlinear regression by 2-compartment model could be applied for the measurement of the clearance rate. Using MIRD system, the absorbed radiation dose was calculated by residence $time{\times}S$. The absorbed whole body radiation dose was negligibly small.

  • PDF