cone beam형 전산화 단층촬영장치를 이용한 절치관의 연구 (A study of incisive canal using a cone beam computed tomography)

  • 김규태;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.7-12
    • /
    • 2004
  • Purpose: To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. Materials and Methods: 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. Results: The mean length of incisive canal was 15.87 mm±2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm±0.76 and 3.89 mm± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3°±6.96 and 117.45°±7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r= 0.258). Conclusion : This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  • PDF

Cone beam형 전산화 단층촬영장치를 이용한 설공의 해부학적 구조 (Anatomical structure of lingual foramen in cone beam computed tomography)

  • 기민우;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Purpose: To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Materials and Methods : Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. Results: In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03±0.08, and both lateral lingual foramina was 0.20±0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9mm±0.28, right lateral lingual foramen was 0.92mm±0.23, and left lateral lingual foramen was 0.88mm±0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Conclusion : Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  • PDF

콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발 (Surgical stent for dental implant using cone beam CT images)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

콘빔형전산화단층장치를 이용한 함치성낭의 방사선학적 연구 (Radiographic evaluation of dentigerous cyst with cone beam CT)

  • 박용찬;이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제40권3호
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose : The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Materials and Methods : Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. Results : DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. Conclusions : CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

Cone beam형 전산화단층촬영장치를 이용한 하악 제1대구치 근심 치근의 danger zone에 관한 연구 (Evaluation of danger zone in mesial root of mandibular first molar by cone beam computed tomography (CBCT))

  • 장유리;최용석;최기운;박상혁
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.103-110
    • /
    • 2007
  • Purpose: To examine the danger zone of mesial root of mandibular first molar of patient without extraction using CBCT (cone-beam computed tomography) to avoid the risk of root perforation. Materials and Methods: 20 mandibular first molars without caries and restorations were collected, CT images were obtained by CBCT ($PSR9000N^{TM}$, Asahi Roentgen Co., Japan), reformed and analyzed by V-work 5.0 (CyberMed Inc., Korea), Distance between canal orifice and furcation was measured. In cross sectional images at 3, 4 and 5 mm below the canal orifice, distal wall thickness of mesiobuccal canal (MB-D), distal wall thickness of mesiolingual canal (ML-D), distal wall thickness of central part (C-D), mesial wall thickness of mesiobuccal canal (MB-M) and mesial wall thickness of mesiolingual canal (ML-M) were measured, Results: The mean distance between the canal orifice and the furcation of the roots is 2.40 mm, Distal wall is found to be thinner than mesial wall. Mean dentinal wall thickness of distal wall is about 1 mm, The wall thickness is thinner as the distance from the canal orifice is farther. But significant differences are not noted between 4 mm and 5 mm in MB-D and C-D, MB-D is thinner than ML-D although the differences is not significant. Conclusion: The present study confirmed the anatomical weakness of distal surface of the coronal part of the mesial roots of mandibular first molar by CBCT and provided an anatomical guide line of wall thickness during endodontic treatment.

  • PDF

CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구 (Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation)

  • 공효금;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

CBCT와 Simulation CT를 이용한 치료계획의 선량비교 (Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning)

  • 김대영;최지원;조정근
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.742-749
    • /
    • 2009
  • 최근의 방사선치료용 선형가속기에 부착된 진단용 kV 에너지 영역의 X선 선원과 아모퍼스 실리콘(a-Si)의 검출기로 구성된 온보드영상장치(OBI)를 이용하여 콘빔 전산화단층촬영 영상(CBCT)획득이 가능하다. CBCT영상을 이용하여 치료계획을 세우게 되면 치료실에서 CT영상 촬영이 가능해짐으로써 고식적 치료환자들의 부담이 많이 감소될 수 있고 더 나아가 선량을 재계산하여 치료과정 중 치료계획 재수립도 가능하다. 본 연구에서는 CBCT를 이용한 치료계획과 기존의 모의치료용 CT를 이용한 치료계획을 비교 연구 함으로서 CBCT영상만으로 광자선 선량계산이 정확한지를 평가하고 임상에서 고식적방사선치료를 목적으로 하는 환자들을 대상으로 온라인 방사선치료계획의 가능성을 연구하였다. 선량계산에 필요한 CT수와 밀도간의 상호관계 확인을 위하여 Catphan 600 팬텀을 이용하여 교정곡선을 산출하였고 팬텀과 환자들의 모의 치료용 CT영상과 CBCT영상을 획득하여 치료계획 및 선량계산 된 결과를 비교하였다. CBCT 영상을 이용한 치료계획에서의 MU차이는 중심점에 100cGy 처방하였을 때 Phantom에서의 경우 3~4MU로 약 2.7%, 환자에서의 경우 1~3MU로 약 2.5% 이하로 차이가 났다. 팬텀과 환자에서의 Monitor unit(MU)차이는 2.7%, 2.5% 이내였으나, CBCT영상의 경우 검출기의 크기의 제약 및 환자의 불수의적인 움직임에 의하여 전자밀도가 큰 물질에서 산란선과 artifact의 발생이 크게 증가한다. 따라서 뇌 및 폐 영역의 치료계획시 선량의 오차가 더 커질 수 있어 이에 대한 주의가 요구된다. 치료시작 전 CBCT 영상을 획득하여 환자의 자세와 내부 장기의 위치를 보정하고 선량을 재계산하여 치료계획을 재수립하는 적응방사선치료(ART)를 시행하기 위해서는 산란선과 움직임에 의한 artifact의 감소방안이 마련되어야 할 것으로 사료된다.

영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석 (Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology)

  • 홍동희;김형균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.421-427
    • /
    • 2016
  • 경상북도 소재 100병상 이상의 3개 종합병원 응급실에 설치된 일반촬영장비와 CT장비에 대한 세균 오염도 검사를 실시하여 감염관리에 대한 기초자료를 제공하고 관리방안을 제안하고자하였다. 2015년 12월 1일부터 12월 31일까지 이루어졌으며 경상북도 소재 응급실내의 일반촬영장비와 CT장비를 대상으로 하였다. 일반촬영장비는 업무종사자가 가장 많이 사용하는 control box 위, 노출 버튼 위, 환자의 피부 접촉 부위인 테이블 위 전체와 stand bucky의 grid 위 및 턱 올려놓은 곳 등 총 4곳을 수집하였다. CT장비는 촬영실 업무종사자가 가장 많이 사용하는 control box위와 X-선 노출 버튼, 환자의 피부 접촉 부위인 환자 테이블 위 전체, gantry inner 등 총 3곳을 수집하였다. 영상의학과 응급실내 일반촬영장비에서 검출된 표면 오염 균주는 Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), incubator에서 48시간 배양 후 자라지 않은 세균은 25%를 차지하였다. 또한 영상의학과 응급실 내 CT장비의 검출된 표면 오염 균주는 Stenotrophomonas maltophilia(11%), Enteococcus faecalis(11%), Escherichia coli(11%), incubator에서 48시간 배양 후 자라지 않은 세균은 67%로 대부분이었다. 영상의학과 일반촬영장치의 Stand bucky-grid와 Stand bucky 상연에서 대부분의 세균이 발견되었고, CT장비의 검체 수집 부분 중 Patient table에 집중되어 검출되었다. 이는 여러 질환을 갖고 있는 환자에 의해 오염된 것을 의미하며 균주 모두 면역력이 저하된 환자에게는 치명적인 질환을 일으킬 수 있다. 그러므로 검사 전후 70% 알코올 소독을 통해 감염예방을 하여야 한다.

뇌혈관 검사 시 최적의 영상 진단장치 선정에 관한 연구: MRA, CTA, DSA, 영상 진단장치 중심으로 (A Study on Selection of Optimal Imaging Diagnostic Device for Cerebral Angiography: Focusing on MRA, CTA, and DSA Imaging Diagnosis Devices)

  • 변정수;구은회
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.637-645
    • /
    • 2017
  • 뇌혈관을 관찰할 수 있는 영상 진단장치 중 MRA, CTA, DSA 3장비 영상에 관한 SNR과 CNR을 비교, 분석하여 뇌혈관 검사 시 최적의 검사기기를 알아보고자 하였다. 2016년 11월부터 2017년 5월까지 뇌혈관 진단 검사를 받은 환자 90명을 대상으로 하였고, 측정부위는 Rt MCA, Lt MCA, ACA Image J를 이용하여 측정 하였다. 정량적 분석 결과 MRA의 평균 SNR은 254.87 CNR은 178.13, 신호강도는 326.81, CTA의 평균 SNR은 74.75, CNR은 62.2, 신호강도는 356.66, DSA의 SNR은 26.85, CNR은 25.89, 신호강도는 4400.69로 평가되었다(p<0.05). 결과적으로 SNR과 CNR 모두에서 MRA>CTA>DSA 순으로 측정 되었다. 유의성 평가 방법으로 SPSS 통계 분석 프로그램을 이용하여 ANOVA 분석을 하였고, 사후분석으로 bonferroni method를 사용하여 p<0.05 일 때 유의한 것으로 판단하였다. 결론적으로 본 실험에서 뇌혈관 질환 환자를 무작위로 선정하여 평가하였을 때 최적의 영상진단 장비로 MRA, CTA, DSA의 결과를 얻었다.

변형 근치적 유방절제술 후 방사선치료에서 볼루스 적용횟수에 대한 고찰 (A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy)

  • 홍채선;김종식;김영곤;박영환
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.113-117
    • /
    • 2006
  • 목 적: 유방암으로 진단 받고 변형 근치적 유방절제술(Modified Radical Mastectomy)후 흉벽에 방사선치료를 시행 받고 있는 환자를 대상으로 볼루스(Bolus) 적용에 따른 흉벽(흉터, 수술봉합부위)의 피부선량 변화를 분석 하여 적절한 볼루스 적용횟수를 얻고자 한다. 대상 및 방법: 유방암으로 진단받고 변형 근치적 유방절제술 후 방사선치료를 받고 있는 4명의 여성 환자(우측 2명 좌측 2명)를 대상으로 하였다. 흉벽 방사선조사는 4 MV광자선으로 매일 2 Gy씩 주 5회, 접선조사로 치료하였고, 총 조사선량은 50 Gy였는데 동측 내유방림프절은 포함하지 않았다. 치료 계획을 위한 전산화단층촬영에서 흉터 부위의 위치 확인을 위해 방사선비투과성물질인 Angio-catheter를 흉터 위에 위치시켰다. 획득한 영상을 이용하여 치료계획을 세웠고, 전산화치료계획장치에서 흉터부위 좌우 2 cm 영역을 포함하는 두께 0.5 cm, 넓이 6 cm의 볼루스를 적용시켰다. 계획한 내용을 바탕으로 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우에 대하여 선량분포 변화와 피부선량을 비교 분석하였고 열형광선량계 (Thermoluminescent dosimetry: TLD, Harshaw, USA)를 이용하여 관심 부위(흉터 부위 3 지점, 흉터 좌측 1 cm 3지점, 흉터 우측 1 cm 3지점) 9개 지점의 선량을 실측하였다. 결 과: 전산화치료계획장치에서 얻어진 선량분포를 통해 분석한 결과, 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우 모두에서 흉벽 부위에 $95{\sim}100%$ 선량이 감싸고 있었으나, 흉터 주위 피부선량에 있어서는 볼루스를 적용하지 않은 경우($50{\sim}75%$)와 볼루스를 적용한 경우($100{\sim}105%$)가 큰 차이를 보였다. 선량분포를 통한 관심지점의 피부선량은 볼루스를 적용하지 않은 경우에 비해 볼루스를 적용한 경우에서 환자 1번 23.3%, 환자 2번 35.6%, 환자 3번 34.9%, 환자 4번 41.7%의 선량 증가를 보였다. 볼루스를 적용하지 않은 경우와 볼루스를 적용한 경우의 TLD 평균 측정치는 환자 1번 161.1 cGy 209.3 cGy 환자 2번 150.2 cGy, 200 cGy, 환자 3번 150.5 cGy, 211.4 cGy, 환자 4번 155.5 cGy 198.6 cGy의 결과를 얻었다. 결 론: 본 원에서 변형 근치적 유방절제술 후 흉벽 방사선치료의 가장 적절한 볼루스 적용 횟수는 전 치료횟수의 $50{\sim}60%$ 적용이다.