• Title/Summary/Keyword: 전력 소모 절감

Search Result 186, Processing Time 0.035 seconds

Communication Module Selection Algorithm for Energy Saving of Smartphone (스마트폰 에너지 절감을 위한 통신모듈 선택 알고리즘)

  • Lee, Chang-Moo;Lee, Seung-Jae;Choi, Deok-Jai
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.22-31
    • /
    • 2012
  • A Smartphone is an intelligent device combined mobile phone and pc's support functions, and can perform multiple functions to satisfy the demands of users. It has excellent processing power and communication modules(DMB, Wi-Fi, Bluetooth, NFC etc) to carry out the demands of users. But continuous using of battery power on processor and equipped modules causes acceleration of battery consumption. This means that effective power management in devices like smartphone is important. Therefore, the management of power consumption on system execution and communication module is a serious issue in this field of study. In this paper, we would like to propose a communication module selection algorithm based on energy consumption parameter of each communication module and data transfer time. Our scheme automatically select appropriate communication system to reduce high energy consumption on bluetooth sleep mode so that this scheme is more efficient and effective thus improving user convenience in longer usage time. Experimental results showed the 20% energy saving.

Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving (에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석)

  • Kim, Jihye;Lee, Kyung-Hyuk;Lim, Jae-Lim
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.314-322
    • /
    • 2019
  • A worsened drought in Chungnam province of Korea due to climate change and increasing water demand at Daesan industrial complex have motivated the 100,000 ㎥/d seawater desalination project. In this study, therefore, the comprehensive analysis of parameters affecting the reverse osmosis (RO) performance was conducted. Under the various conditions of feedwater salinity and temperature in Daesan, energy consumption was calculated as 2.39 ± 0.13 kWh/㎥. The decrease in membrane flux and recovery rate positively impacted annual operation cost. The average total dissolved solids (TDS) of the permeate and energy consumption with highly permeable membrane according to the membrane manufacturer were 3.84 mg/L and 2.22 ± 0.13 kWh/㎥, respectively. In addition, energy saving up to 0.29 kWh/㎥ or cost reduction of membrane module up to 15.6% is expected by changing the RO configuration from full two pass to partial or split partial two pass.

Dynamic Allocation of ATIM Window Size using Kalman Filter in IEEE 802.11 DCF (IEEE 802.11 DCF 에서 칼만 필터를 통한 ATIM 창 크기의 동적 할당 기법)

  • Lee, Jangsu;Yoo, Seunghwan;Kim, Seungwook;Kim, Sungchun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.11a
    • /
    • pp.995-998
    • /
    • 2007
  • 무선 네트워크에서 사용되는 단말기는 이동성이라는 특징상 한정된 에너지를 사용하여 동작하게 된다. 따라서 무선 호스트에 의해 소모되는 에너지의 양을 감소시키기 위한 기술은 대단히 중요하다. 이러한 기술적 지원을 위해 IEEE 802.11 에서는 DCF (Distributed Coordination Function) 전력 절감 메카니즘을 제안하고 있다. 그런데, DCF 를 위한 IEEE 802.11 전력 절감 메카니즘에서는 ATIM 창 동안 노드들은 비콘 기간 동안 깨어 있는 상태로 있을 것인지를 결정하기 위해서 control packet 을 교환 하는데, 이러한 ATIM 창 크기는 각각의 노드들의 전력 절감에 상당한 영향을 미친다. 그래서 ATIM 창 크기를 효율적으로 할당하기 위해 DPSM 과 같은 기법들이 개발되었다. 본 논문은 ATIM 창 크기를 동적으로 증감시켜서 ATIM 창 시간동안 소모되는 에너지를 줄이도록 하였다. ATIM 창 크기를 동적으로 할당하기 위하여 통계적 예측 기법인 칼만 필터를 도입하여 예측시스템을 구축하였으며, 이 예측 시스템을 통해 다음 상태에서 적용할 ATIM 창 크기를 예측하여 동적으로 할당하도록 하였다. 실험 결과 네트워크 생존 시간을 28.6% 증가시켰고, ATIM 창 크기 예측값의 오차는 4.42%로 나타났다.

  • PDF

An Integrated Power Management Framework for WiFi-based Mobile Embedded Systems (WiFi기반 모바일 임베디드 시스템을 위한 통합 전력 제어 기법)

  • Min Jung-Hi;Cha Ho-Jung
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.658-665
    • /
    • 2006
  • In these days, the demand of users to extend available period of mobile systems is increased according as the functions of mobile systems have been varied and the use of multimedia application has been increased. This paper proposes an integrated power management framework that considers executed workload types for effective energy management. The conventional methods use DVFS technique for CPU and DPM technique for WNIC separately or simply combine them based on the assumption that they are orthogonal one another. However, the proposed mechanism determines the kind of workload under analysis of the characteristics of workloads incoming through a WNIC. The proposed method can reduce energy consumption of system level effectively by controlling CPU and WNIC to proper power mode based on analyzed characteristics of workload. The experimental result shows the proposed method reduces energy consumption by 9% for BE (Best Effort) workload, CBR (Constant Bit Rate) workload, and Interactive workload on average and by 16% to maximum when compared with the conventional methods which simply combine DVFS technique for CPU and DPM technique for WNIC.

Power Management System of Base Station Equipment for Mobile Communication Based on Smart Grid (스마트그리드 기반의 이동통신장치의 전력관리 시스템)

  • Lee, Kwanho;Song, Jihun;Kang, Sanggee;Yoo, Hosang;Lee, Naein
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.969-972
    • /
    • 2015
  • Many studies have been carried out in order to develop a frequency efficient communication system than the current communication system for satisfying the increasing demands of wireless data services in mobile communication systems. If a communication system dramatically improving the frequency utilization efficiency is not developed, service providers must maintain more number of base station equipments to meet the increasing demands of wireless data service. Service provider needs a system or method to reduce maintenance costs. Demands of wireless data service are changed according to time of day, location and so on. Power consumption can be reduced if the supplied power of communication systems is controlled by wireless data traffics. This paper describes the design and implementation of power management system of mobile communication base station's equipment based on smart grid. The proposed power management system controls the supplied power to the mobile communication infrastructures depending on the demand of wireless data. Field test results of the implemented system show the proposed system saves 26% of the power consumption in the base stations.

  • PDF

Experiments on IEEE 802.11b Wireless LAN Infrastructure Performance with Transmission Power Management (IEEE 802.11b Infrastructure 환경에서 전송 전력 관리를 통한 성능 실험)

  • 정희록;김성훈;박창윤
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.481-483
    • /
    • 2003
  • 이동 장비들은 베터리를 전원으로 하고 있으며 이들이 사용하는 무선 통신에 소모되는 전력을 줄이는 것은 베터리의 적은 전력량을 고려해 볼 때 매우 중요하다. 본 논문은 802.11b infrastructure환경에서 저전력 통신 기법을 개발하기 위해 전송 전력이 통신 성능에 미치는 영향을 실험하였다. 실험 결과 사무실 수준의 공간에서는 성능에 영향을 미치지 않으면서 전력을 낮출 수 있고, 이 경우 전송으로 인한 전력 소비에서 18%정도의 전력 절감이 가능하리라는 것을 확인 할 수 있었다.

  • PDF

승강기 제어반 교체로 전력소모 $50\%$ 절감

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.3
    • /
    • pp.28-29
    • /
    • 2000
  • 만약 건물마다 엘리베이터가 없다면 우리 생활은 어떻게 될까? 고층건물을 걸어서 오르내려야 하는 불편함과 시간낭비, 그밖에도 생활의 제약을 많이 겪어야 할 것이다. 이처럼 우리에게 편리함을 주는 문명의 이기지만 안전관리를 소홀히 할 경우에는 소중한 생명을 위협하는 무기로 돌변한다. 이번 호 ''ESCO피플''에 초대한 최종성씨는 12년동안 성모병원의 승강기 관리담당자로서 병원내 승강기를 안전하고 편리하면서도 전력 손실을 줄일 수 있도록 효율적으로 관리하는데 노력해왔다.

  • PDF

A Cutoff Device for Saving Standby Power (대기전력 차단 장치)

  • Lee, Jae-Hwon;Choi, Suk-Hwan;Park, Jin-Han;Sin, Ho-Chul;Sin, Young-Jin;Choi, Suk-Min
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.109-110
    • /
    • 2011
  • 현재 가정 및 사무실 사용전력 가운데 실제 이용되지 않고 전자기기의 대기상태에서 버려지는 대기소모 전력이 5~10 %에 이르는 것으로 보고되고 있다. 이를 줄이기 위한 노력이 선진국들뿐만 아니라 국제적 차원에서 경주되고 있다. 우리나라도 가전기기 및 산업기기의 자동화 및 on-line화에 따른 대기 소모 전력이 점차 증가하고 있어 전기에너지 낭비의 큰 요인이 되고 있을 뿐만 아니라, 온실가스 배출량을 감축하려는 국제협약에도 배치된다. 따라서 대기전력을 줄이기 위한 범국가적인 제도적 기술적 노력을 필요로 한다. 본 논문에서는 대기전력절감기술 및 최근 국제동향과 대기전력 차단 장치의 무선화를 기술하였다.

  • PDF

Instruction Queue Architecture for Low Power Microprocessors (마이크로프로세서 전력소모 절감을 위한 명령어 큐 구조)

  • Choi, Min;Maeng, Seung-Ryoul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.56-62
    • /
    • 2008
  • Modern microprocessors must deliver high application performance, while the design process should not subordinate power. In terms of performance and power tradeoff, the instructions window is particularly important. This is because a large instruction window leads to achieve high performance. However, naive scaling conventional instruction window can severely affect the complexity and power consumption. This paper explores an architecture level approach to reduce power dissipation. We propose a low power issue logic with an efficient tag translation. The direct lookup table (DTL) issue logic eliminates the associative wake-up of conventional instruction window. The tag translation scheme deals with data dependencies and resource conflicts by using bit-vector based structure. Experimental results show that, for SPEC2000 benchmarks, the proposed design reduces power consumption by 24.45% on average over conventional approach.