• 제목/요약/키워드: 전력연구원

검색결과 959건 처리시간 0.025초

FR ESS 의 화재 예방, 설비 개선 및 보호 기술 현장 적용 (Fire Protection, Facility Improvement and Protections for FR ESS)

  • 이일용
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.35-43
    • /
    • 2021
  • 한국전력공사 전력연구원에서는 2018 년 고창 전력시험센터에서 최초 화재 발생 이후, ESS 시스템의 화재 발생 원인에 대한 분석 및 실증시험을 수행하였으며, 이를 통해 현장에서 화재 발생을 최소화할 수 있는 다양한 설비개선안을 도출하였다. 도출된 설비개선안을 통하여 기술지원 요청 부서에서는 전국의 모든 현장 적용을 시행하고 있으며, 이를 통하여 한전이 보유한 모든 ESS 설비는 2021 년 내재 가동될 예정이다.

화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증 (Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack)

  • 신동호;김영훈;서현수;홍기정;김학준;김용진;한방우;이가영;천성남;황정호
    • 한국입자에어로졸학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

독립형 에너지 하우스 전력시스템에서의 BIPV용 Optimizer에 대한 연구 (A Study on Optimizer for Building Integrated Photovoltaic System of Energy Independent House)

  • 조영찬;신덕식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.229-230
    • /
    • 2018
  • 본 논문은 태양광 기반의 '독립형 에너지 하우스'의 전체 전력 시스템과 태양광 외장재 모듈의 에너지를 효율적으로 최대 수급하기 위한 BIPV(Building Integrated PV)용 Optimizer의 개발에 대해 기술한다.

  • PDF

확장칼만필터 기반 주파수 조정용 ESS의 SOC 추정 연구 (SOC estimation of ESS for frequency regulation based on extended kalman filter)

  • 권순종;최진혁;임지훈;이성은;김종훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.201-203
    • /
    • 2019
  • ESS의 데이터에 노이즈가 발생하였을 때 배터리의 상태를 정확하게 추정하는 것은 어려운 부분이며, 부정확한 배터리 상태 추정은 시스템의 안전성 및 신뢰성을 하락시킬 수 있다. 실제 사용되는 시스템의 대부분의 데이터에는 노이즈가 발생하며, 이러한 노이즈를 고려하여 배터리의 상태를 정확하게 파악하는 연구는 매우 중요하다. 본 논문에서는 주파수 조정 용도로 ESS가 사용되었을 때 배터리의 운전 패턴을 생성하고, 입력 데이터에 심각한 노이즈가 발생하였을 때 EKF 알고리즘을 사용하여 배터리의 상태를 정확하게 추정하는 것을 보여준다.

  • PDF

송전급 초전도케이블 신뢰성평가를 위한 시험방법 (Reliability Test Recommendations of Transmission Level HTS Power Cable)

  • 박진우;양병모;강지원;조전욱;이수길;심기덕;김성래
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.29-33
    • /
    • 2010
  • For last 10 years, there are big progress and many efforts in the development of HTS power equipments by some country including South Korea. Especially HTS cable system is the strongest candidate among them from the viewpoint of applying to real grid, because of the feature of it, compact and large capacity. In South Korea, transmission level 154kV, the world top voltage class, HTS cable system was installed and has been tested in KEPCO Gochang Underground Cable Test Field since the early of 2010 in order to meet test requirements made by KEPCO, the only grid company in South Korea. The type test of it will be completed by October 2010 and subsequently long-term load cycle test will be performed during 6 months. Also in the near future, KEPCO has a plan to demonstrate transmission level HTS cable system in real grid, in order to meet practical requirements and confirm the feasibility of it. This paper says the test plan of transmission level 154kV HTS cable system and the way how to test it.

22.9kV, 50MVA급 초전도 전력케이블 DC $I_c$ 측정에 관한 연구 (The study on the DC Ic measurement in the 22.9kV, 50MVA HTS power cable)

  • 최석진;이상진;심기덕;조전욱;장현만;이수길;손송호;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.28-31
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established.

600V급 GaN FET의 스위칭 특성 분석 및 성능 평가 (Switching Characteristic Analysis and Performence Evaluation of 600V GaN FET)

  • 임종헌;김재원;박준성;김진홍;최준혁
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.279-280
    • /
    • 2019
  • 본 논문에서는 3KW급 전력변환장치에 적용 가능한 650V급 GaN FET를 사용하여 Half-bridge 구조의 개발보드를 설계 및 제작하고, Double pulse test 실험을 통해 Turn-on 및 off 시스위칭 특성을 분석하였다. 또한 동기정류식 Buck 컨버터에 GaN FET을 적용하고, 유사한 전압 및 전류 정격의 Si MOSFET 소자와 시스템 효율을 비교하여 GaN FET 전력반도체의 성능을 평가하였다.

  • PDF

공동 활용 컴퓨팅 시스템에서의 사용자 작업별 전력 사용량 생성 기능 구현 (Implementation of power consumption generation for each user job of shared utilization computing system)

  • 권민우;고동건;윤준원;홍태영
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2020년도 추계학술발표대회
    • /
    • pp.24-25
    • /
    • 2020
  • 한국과학기술정보연구원(KISTI)에서는 슈퍼컴퓨터 5호기인 누리온과 보조시스템인 뉴론 시스템을 이용하여 공동 활용 서비스를 진행하고 있다. 다수의 사용자가 접속하여 사용하는 이와 같은 컴퓨팅 시스템들은 구축비용 뿐 아니라 운영 중에 발생하는 전력 소비 비용이 상당하다. 본 논문에서는 뉴론에서 수행되는 사용자의 작업별 전력 사용량을 생성하는 기법에 대해 소개하고 전력 소비량을 조절할 수 있는 방안에 대해 논의한다.

GaN HEMT를 적용한 3kW급 단상 인버터의 스위치 특성 분석 (Switching Characteristic Analysis of 3kW Single-Phase Inverter based on GaN HEMT)

  • 한석규;최수호;주동명;박준성;최준혁
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.294-295
    • /
    • 2020
  • 차세대 전력반도체 중 하나인 GaN HEMT(Gallium Nitride High Electron Mobility Transistor)는 낮은 온 저항, 고속 스위칭 및 낮은 출력 커패시턴스 특성을 가지므로 더 높은 전력밀도를 달성할 수 있다. 그러나 낮은 문턱 전압 및 높은 dv/dt로 인해 외부 요인에 취약하다. 본 논문에서는 GaN HEMT를 3kW급 단상 인버터에 적용 시 발생한 문제점을 분석하고 해결방안을 제시한다.

  • PDF