A Web-based Monitoring of Electrical Energy Consumption and Data Analysis of Smart Farm Facilities (스마트팜 전기 사용에 대한 웹기반 실시간 모니터링 시스템 운영 및 전력사용량 분석)

  • Lee, Mu Yeol;Sim, Sojeong;Kim, Eun-jeong;Han, Young-Soo
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.366-375
    • /
    • 2022
  • The monitoring of electricity consumption using Internet of Things (IoT) technology is attracting attention as a technology to reduce operation costs of smart farms. In this study, we propose a method to apply a real-time electrical consumption monitoring system (the e-Gauge system) and utilization of the collected data real-time while a melon-producing smart farm is in operation. For this purpose, the electrical consumption data for the individual smart-farm facilities such as boilers, nutrient distribution systems, automatic controllers, circulation fans, boiler controllers, and other IoT-related utilities were collected during three months of melon cultivation period. By using the monitoring results, the electrical energy consumption pattern was analyzed as an example, and necessary considerations needed to optimally utilize the measurement data were suggested. This paper will be useful in lowering the technological implementation barriers for new researchers to build a electrical consumption monitoring system and reducing trial and errors in the usage of the generated data.

Study on the Development of LED streetlight control system using GPS satellite communication and Arduino (GPS 위성통신과 아두이노를 이용한 에너지 절약형 LED 가로등 제어 시스템 개발에 관한 연구)

  • Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.632-637
    • /
    • 2016
  • A streetlight control system was developed using information technology and LED lights for efficient management and energy savings. The proposed system can control the power usage of an LED streetlight luminaire using GPS satellite communication and an Arduino with a built-in microprocessor. A control circuit was designed to control the current using GPS, a control unit, transistor, resistor, and constant-current supply circuit. The circuit was validated through experiments with normal operation. Using GPS, the control system extracts accurate time and location information according to the season, and it controls the current supplied to the LED streetlight according to the extracted time. Power consumption was reduced by more than 11%. The control system could reduce accidents caused by conventional lighting systems used to save energy, and it could improve the inefficient management of energy by preserving constant brightness of a streetlight at times and in areas that have less traffic.

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Power Save of Marine Tracker Buoy System Based on NB-IoT for Identification of Fishing Gear (어구 자동 식별을 위한 NB-IoT 기반의 해양 트래커 부이 시스템의 전력 절감)

  • Nam, Sung-Il;Kim, Min-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.545-550
    • /
    • 2018
  • Ministry of Oceans and Fisheries declared action plan for the electric fishing gear using real name in order to prevent overusing the fishing gear and to reduce discarded fishing gear. It is needed for a technique that can efficiently transmit the information including the type and location of the fishing gear and the user's real name to the fishing boat and the control center using IoT-based communication. The marine tracker buoy system, which is placed on the water for a long time, transmit the position data and the state data of the buoys to the control center in the ground by using NB-IoT channels. In this paper, we propose the algorithm for the low-power operation of the marine tracker buoy system is proposed and test results of current consumption in the marine tracker buoy system with the proposed algorithm is investigated.

A Study on the Effect to Reduce the Greenhouse Gas with a Pump Scheduling System in Water Supply Plant : Energy Efficiency Improvement CDM Project in Paldang Pumping Station(III) (펌프 스케쥴링 시스템을 적용한 수도사업장의 온실가스 저감효과 분석 : 팔당3 취수장 에너지효율향상 CDM 사업을 중심으로)

  • Kim, Min Su;Lee, Hyung Muk;Park, Min Su;Gwon, Gi Beom
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.63-75
    • /
    • 2013
  • The purpose of this study is to analyze the green-house gas emission reduction of the pump scheduling system applied to the water-supply facilities in all objectivity with AMS-II.C/Version 13 in CDM methodology. To calculate the baseline and project emission in Paldang Pumping Station (III) the data about water flow, water level, electricity consumption, etc. before and after the implementation of project was used. This study considers internal facility (mostly for lighting) electricity consumption and grid loss in order to get more accurate emission reductions. The methodology used in this study will be able to apply to different energy improvement techniques to calculate emission reductions in water supply facilities.

The Numerical Analysis of Two-Dimensional Electrokinetic Remediation Characteristics Dependent on Electrode Configurations (전극배치에 따른 2차원적 동전기 정화 특성의 수치해석)

  • Kim, Soo Sam;Han, Sang Jae;Kim, Byung Ill
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5C
    • /
    • pp.291-301
    • /
    • 2006
  • In this study the characteristics of electrokinetic remediation, which is dependent on a various electrode configuration, was predicted from 2-D numerical analysis program (HERO-2D). Based on the predicted results for one dimensional and two dimensional electrode configurations, the optimized electrode configuration was determined by analyzing remediation efficiency, consumed electric power, installation cost of electrode and so on. When proposed electrode configurations were applied for in-situ remediation of the soils contaminated by heavy metals, the electrode configuration of high remediation efficiency should be chosen in case the high removal effect would be required, and one dimensional electrode configuration should be chosen in case the hard field works would be expected. Because the rectangular electrode configuration is better than others for consumed electric power, remediation efficiency per unit power, installation cost of electrode and so on, it can obtain the best results for the cost reduction.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

A Localization Method Using RF Transmission Levels in Wireless Sensor Networks (무선 센서 네트워크에서 RF 전송 레벨을 이용한 위치 측정 기법)

  • Yun, Chae-Sang;Hahn, Joo-Sun;Ha, Rhan
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10d
    • /
    • pp.366-371
    • /
    • 2007
  • 무선 센서 네트워크는 경제적, 환경적 목적으로 다양한 방면에서 활용되고 있다 이 때, 배치된 각 센서의 위치를 파악하는 것은 센서 네트워크에서 가장 기본적이며 가장 중요한 문제 중의 하나이다. 기존 논문에서 제안된 센서 위치 측정 방법은 특별한 장비를 장착하거나 특정한 환경의 지역에 한정시킨 방범으로 제한하고 있는 경우가 대부분이다. 하지만 어떠한 관심 지역의 환경은 언제라도 바뀔 수 있다. 또한, 센서가 위치할 환경의 기온, 풍속 등을 미리 안다는 것은 비현실적인 가정이다. 더구나 각각의 센서에 특별한 장비를 장착한다는 것은 비용 절감을 이유로 센서 네트워크를 운영하는 경우 오히려 그것을 이용하지 않는 경우보다 비용이 더 들 수도 있다. 이에 본 논문에서는 센서 노드의 기본적인 통신 기능은 이용하여, 환경에 순응적으로 센서의 위치를 측정할 수 있는 방법을 제안하고자 한다. 센서 노드에서 기본적으로 제공하는 통신 기능은 RF 전파를 보낼 때 전송 레벨을 달리하여 보낼 수 있다. 이러한 기본적인 기능을 이용하여 위치를 측정하게 되면 전체적인 센서 네트워크의 비용이 절감될 뿐만 아니라 환경에 순응적인 위치 측정이 가능하게 된다. 또한, 각 노드의 위치가 정해진 후 다른 노드와 통신할 때 전파의 세기를 조정함으로써 RF 통신에서 소모되는 전력량을 줄일 수 있다. 따라서 본 논문에서 제안하는 전송 레벨을 이용한 위치 측정 방법은 단순히 위치를 측정한다는 의미뿐 아니라 환경에 순응적으로 작동한다는 장점이 있다. 향후 네트워크 내에서 통신에 소비되는 전력을 줄일 수 있다는 점에서도 중요한 의미를 지닌다.를 집행하는 caspase의 활성 형태인 cleaved caspase-8, -9, -7, -3의 단백질 수준이 목향 헥산추출물의 처리에 의해 증가하였고 caspase-3의 표적 단백질 중 하나인 PARP의 불활성 형태인 cleaved PARP의 단백질 수준도 현저하게 증가하였다. 이 결과들은 목향 헥산 추출물이 LNCaP 세포의 apoptosis를 유도함으로써 전립선 암세포의 증식을 억제함을 보여주는 것이며 목향 헥산추출물에 의한 apoptosis 유도는 caspase 활성 증가와 Bak 및 t-Bid 단백질의 증가에 의한 것임을 제시한다. 따라서 앞으로 항암효과를 나타내는 성분의 동정 및 동물실험을 통하여 좀 더 면밀한 기전 연구가 수행된다면 목향 헥산추출물은 화학적 암예방 물질이나 치료제로 개발될 수 있을 것으로 사료된다.적 분해층과 마모질이가 가장 깊은 것으로 나타났으며 flowable type의 복합레진과 컴포머는 표면 경도와 마모도에서 양호한 결과를 보였다. 이상의 결과 복합레진과 컴포머의 평가요소로서 마모도와 함께 가수분해도 고려되어야 할 것으로 사료된다.증후군 환자에서 대조군에 비해 높은 비율을 보였다.er thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3

  • PDF

Power-efficiency Analysis of the MIMO-VLC System considering Dimming Control (조광제어를 고려한 MIMO-VLC 시스템의 전력 효율 분석)

  • Kim, Yong-Won;Lee, Byung-Jin;Lee, Byung-Hoon;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.169-180
    • /
    • 2018
  • White light-emitting diodes (LEDs) are more economical than fluorescent lights, and provide high brightness, a high lifetime expectancy, and greater durability. As LEDs are closely connected with people's daily lives, dimming control of LED is an important component in providing energy savings and improving quality of life. In visible light communications systems using these LEDs, multiple input multiple output (MIMO) technology has attracted a lot of attention, in that it can attain the channel capacity in proportion to the number of antennas. This paper analyzes the power performance of three kinds of modulation in visible light communications (VLC) systems applied space-time block code (STBC) techniques. The modulation schemes are return-to-zero on-off keying (RZ-OOK), variable pulse position modulation (VPPM), and overlapping pulse position modulation (OPPM), and dimming control was applied. The power requirements and power consumption were used as metrics to compare the power efficiency in $2{\times}2$ STBC-VLC environments under the three kinds of modulation. We confirm that dimming control affects the communications performance of each modulation scheme. VPPM showed greater consumption among the three modulations, and OPPM showed energy savings comparable to VPPM.

Power Generating Performance of Photovoltaic Power System for Greenhouse Equipment Operation (온실설비 작동용 태양광발전시스템의 발전 성능 분석)

  • Yoon, Yong-Cheol;Bae, Yong-Han;Ryou, Young-Sun;Lee, Sung-Hyoun;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2009
  • For the purpose of reducing the cost for greenhouse operation by acquiring the electric power necessary for it, this study installed a solar photovoltaic system on the roof of the building adjacent to green-houses and experimentally examined the quantity of power generation based on weather conditions. The results of the study are as per the below: The maximum, average and minimum temperature while the experiment was conducted was $0.4{\sim}34.1,\;-6.1{\sim}22.2$, and $-14.1{\sim}16.7^{\circ}C$ respectively, and the solar radiation was $28.8MJ{\cdot}m^{-2}$ (maximum), $14.9MJ{\cdot}m^{-2}$ (average), and $0.6MJ{\cdot}m^{-2}$ (minimum). The quantity of electric power didn't increase in proportion to the quantity of solar radiation and instead, it was almost consistent around 750W. Daily maximum, average and minimum consumption of electric power was 5.2kWh, 2.5kWh and 0kWh respectively. Based on the average electric power consumption of the system used for this experiment, it was sufficient in case the capacity and the working time of a hot blast heater are small, but it was short in case they are big. In case the capacity of the hot blast heater is big, the average electric power quantity will be sufficient for array area $21m^2$, about three times of the present area. In summer when the temperature of the array becomes high, the generation of electric power didn't increase in proportion to the quantity of solar radiation, but this experiment result shows a high correlation between two factors (coefficient of correlation 0.84).