A Study on the Effect to Reduce the Greenhouse Gas with a Pump Scheduling System in Water Supply Plant : Energy Efficiency Improvement CDM Project in Paldang Pumping Station(III)

펌프 스케쥴링 시스템을 적용한 수도사업장의 온실가스 저감효과 분석 : 팔당3 취수장 에너지효율향상 CDM 사업을 중심으로

  • Kim, Min Su (Dept. of Climatic Environment, Korea University) ;
  • Lee, Hyung Muk (Dept. of Green Energy, Korea Water Resources Corporation) ;
  • Park, Min Su (Dept. of Green Energy, Korea Water Resources Corporation) ;
  • Gwon, Gi Beom (Dept. of Paldang, Korea Water Resources Corporation)
  • 김민수 (고려대학교 기후환경학과) ;
  • 이형묵 (한국수자원공사 녹색에너지처) ;
  • 박민수 (한국수자원공사 녹색에너지처) ;
  • 권기범 (한국수자원공사 팔당권관리단)
  • Received : 2013.02.24
  • Accepted : 2013.03.25
  • Published : 2013.03.31

Abstract

The purpose of this study is to analyze the green-house gas emission reduction of the pump scheduling system applied to the water-supply facilities in all objectivity with AMS-II.C/Version 13 in CDM methodology. To calculate the baseline and project emission in Paldang Pumping Station (III) the data about water flow, water level, electricity consumption, etc. before and after the implementation of project was used. This study considers internal facility (mostly for lighting) electricity consumption and grid loss in order to get more accurate emission reductions. The methodology used in this study will be able to apply to different energy improvement techniques to calculate emission reductions in water supply facilities.

본 연구의 목적은 에너지 절감 및 온실가스 감축을 위해 수도사업장에 도입된 펌프 스케쥴링 시스템의 온실가스 감축 효과를 객관적으로 분석하는데 있다. 이 목적을 달성하기 위해서 온실가스 감축량 산정시 CDM 방법론 AMS-II.C/Version 13을 적용하였다. 베이스라인과 프로젝트 배출량을 산정하기 위해 사업 전후의 유량, 흡수정과 써지탱크의 수위 차, 전력량 데이터를 이용하였다. 감축량 산정의 정확성을 높이기 위해 펌프 운영과 연관성이 적은 소내 소비 전력과 계통손실도 고려하여 계산하였다. 본 연구에서 적용된 방법론과 계산식은 수도사업장에서 온실가스 감축을 위해 적용되는 타 기술의 감축량 산정 시에도 일정 부분 적용 가능할 것으로 판단된다.