• Title/Summary/Keyword: 전력노이즈

Search Result 290, Processing Time 0.041 seconds

Frequency Characteristic Analysis of Noise Cut Transformer for the Power Line Noise Reduction (전원노이즈 억제용 NCT의 주파수 특성 해석)

  • 이재복;허창수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.850-859
    • /
    • 1998
  • Broadband noise with frequency components in the range from several kHz up to tens of MHz is widespread in the AC power line. Noise filter or surge suppressor, often used to suppress the conducted noise, have a poor performance in reducing the common-mode. In this paper, we proposed a lumped-circuit analysis model for Noise Cut Transformer(NCT) which can be used to suppress both the common mode and normal-mode noise. The simulations with our model show a good agreement with experimental results. It has been also shown that our NCT is superior to noise filter and general isolation transformer in reducing the conducted noise.

  • PDF

Performance of EV Charging System in Energy Internet (에너지인터넷에서 전기차 충전 시스템의 성능)

  • Kim, Soo Hyun;Sun, Young Ghyu;SIm, Isaac;Hwang, Yu-Min;Kim, Jin Young
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.11a
    • /
    • pp.94-95
    • /
    • 2019
  • 본 논문에서는 에너지인터넷의 한 분야인 전력선 통신 기반 전기 자동차 충전 시스템 구축에서 발생하는 임펄스 노이즈 동기화 문제를 해결하기 위해 OFDM에서 사용하는 프레임 동기화 방식을 제안한다. Kasami sequence를 통한 동기화 방식으로 전력선 통신의 임펄스 노이즈 동기화 결과를 확인한다.

  • PDF

A current control of Grid-connected system using DFT Method (DFT를 이용한 계통연계 시스템의 전류제어)

  • Park, M.Y.;Lee, S.H.;LIM, S.K.;Yang, H.Y.;Park, S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.500-501
    • /
    • 2011
  • 신재생 에너지를 계통과 효율적으로 연계하기 위해서는 일정한 DQ파형이 필요하다. 하지만 부하의 변동으로 전류가 작을 경우 노이즈의 영향으로 제어에 어려움을 겪게 된다. 따라서 본 논문에서는 효율적인 전류 제어를 하기 위해 DFT 기법을 사용하여 노이즈를 제거하고 기본파 전류 파형을 추출하여DQ 변환을 수행한다.

  • PDF

Electromagnetic simulation of HVDC System sub-modules through modeling (모델링을 통한 HVDC System 서브모듈의 전자기 시뮬레이션)

  • Sun, Daun;Song, Sunggeun;Kim, Kibeom
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.479-480
    • /
    • 2019
  • 전압형 MMC HVDC 시스템은 다수의 서브모듈이 직렬로 구성되어 있으며, 서브모듈 내부의 고전압 반도체 소자는 수 kV로 스위칭 된다. 이때 발생하는 dV/dt에 의해 많은 고주파 성분의 과도노이즈가 전자파 방사 문제를 야기 시킨다. 본 논문에서는 HVDC 시스템의 전자파 노이즈 분석을 위해 1개의 서브모듈에 대한 측정 및 측정 결과를 바탕으로 컴퓨터 시뮬레이션 모델링을 진행하였다.

  • PDF

The Effect Analysis in case of the Countermeasure and Trouble-Examples for the Noise of Control Equipment System (제어설비 계통에서의 노이즈장해 사례 및 대책별 효과 분석)

  • Kim, Hong-Ju;Yoo, Sang-Bong;Lee, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.75-81
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise the mis-operation equipment and demage program memories of control circuits. In this paper, the noise character of the various control equipment system has been measured and analyzed. Additionally, the countermeasure to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and confirmed the effective results to solve the trouble of noise.

A Study on the Countermeasure and Trouble-Examples by Noise in Control Equipment System (제어설비 계통의 노이즈장해 사례 및 대척에 관한 연구)

  • Yoo, Sang-Bong;Kim, Hong-Ju;Lee, Ho-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.325-330
    • /
    • 2005
  • Recently an increase of sensor and power trandusers in control equipment system has caused many kinds of noise. These kinds of noise came out the mis-operation equipment and demage program memories of control circuits. In this paper, the noise generation of control equipment system han been measured and analyzed. Additionally, the effective protection equipments to reduce noise like as Noise Cut Transformer, Equipotential Bonding, Power Noise Rejector, Noise Filter has been applied and proposed the measured results.

  • PDF

Dimming Control system Using Power Line Modem (전력선 통신을 이용한 조광제어 시스템)

  • 주병훈
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.107-110
    • /
    • 2000
  • 전력선 통신을 이용한 조광제어 시스템은 전자식 안정기의 주파수 변조 방식을 잉요하여 실시하였다 전력선 통신제어 사용된 data 변조 방식은 FSK 방식을 이용하였으며 안정기의 스위칭 동작에 의해 발생하는 EMI는 140kHz 대역의 노이즈를 발생시키므로 본논문에서는 2단 필터를 사용하여 해당 대역의 EMI 60dB 감쇄시켰다.

  • PDF

Measurement and Analysis of Conduction Noise through Microstrip Line Attached with Composite Sheets of Iron Particles and Rubber Matrix (마이크로스트립 전송선로를 이용한 순철 압분체-고무 복합재의 전도노이즈 흡수특성 측정 및 해석)

  • Kim, Sun-Tae;Oh, Byung-Ki;Kim, Sung-Soo;Cho, Han-Sin;Lee, Jae-Hee
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.5
    • /
    • pp.174-179
    • /
    • 2004
  • Attenuation of conduction noise through microstrip line attached with the high lossy iron flakes-rubber composites has been investigated in GHz frequencies. Microstrip line was designed with characteristic impedance of 50 $\Omega$ and a length corresponding to the center frequency of 3 GHz. Iron flakes were fabricated by mechanical forging of spherical iron powders using an attrition mill. The fabricated microstrip line shows a ideal propagation characteristics of S$\sub$11/ < -60 dB and S$\sub$21/ = 0 dB. Attaching a noise absorbing sheet on the microstrip line, S$\sub$11/ increases to about -10 dB and S$\sub$21/ decreases to -20~-60 dB depending on the length of absorbing sheet. The calculated power loss is as high as 80% in the frequency range 2~8 GHz. It is suggested that the most critical material parameter is magnetic loss for the enhancement of noise attenuation.

HFPD Charasteristic Analysis of Power Transformer in Oxygen Plant (산소 공장 전력용 변압기에서의 HFPD 특성분석)

  • 유권종;김서영;김이곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.673-676
    • /
    • 2000
  • 변압기에서 발생되는 부분방전은 변압기의 운전중 절연열화에 대한 정보를 가장 잘 나타내고있으나, 현장에서 부분방전을 측정하는데 주변 환경적인 문제인 노이즈로 인해 측정의 어려움과 측정된 데이터의 정확한 판단에 어려움이 따른다. 이에 본 연구에서는 노이즈를 완전히 해결하지 못하는 기존방식을 벗어나 높은 영역에서 주위의 노이즈를 덜 받는 HFPD 측정법을 적용하여 광양제철 산소공장에서 데이터를 취득하여 부분방전을 분석하였다. 본 논문에서는 HFPD의 변압기적용과 강인한 현장환경에 따른 영향을 최소화하여 제안한 방법이 변압기의 부분방전 시험에 유용하게 사용할 수 있음을 보였다.

  • PDF