• Title/Summary/Keyword: 전력관리 시스템

Search Result 1,238, Processing Time 0.039 seconds

TPMS Interference Suppression Based on Beamforming (Beamforming을 이용한 TPMS 간섭제거)

  • Hwang, Suk-Seung;Kim, Seong-Min;Park, Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.180-185
    • /
    • 2011
  • The TPMS(Tire Pressure Monitoring System) is an electronic system designed to display the air pressure inside the pneumatic tires and report real-time tire-pressure information to the driver of the vehicle, either via a gange, a pictogram display, or a simple low-pressure warning light. Although the data measured by TPMS sensor is transmitted to internal signal processer in a vehicle through wireless communication, the receiver may suffers from various interferences such as amateur radio station, RFID(Radio-Frequency IDentification) for controlling container, RKE(Remote Keyless Entry) signal, and so on. In this paper, we consider beamforming technology to suppress various high-power interference signals for the TPMS wireless communications. Also, we propose the proper data structure and antenna arrangement for the beamformer inside the vehicle. The performance for the interference suppression is illustrated by computer simulation example.

Security Scheme for Prevent malicious Nodes in WiMAX Environment (노드간 에너지 소비를 효율적으로 분산시킨 PRML 메커니즘)

  • Jeong, Yoon-Su;Kim, Yong-Tae;Park, Nam-Kyu;Park, Gil-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.774-784
    • /
    • 2009
  • A wireless sensor network consisting of a large number of nodes with limited battery power should minimize energy consumption at each node to prolong the network lifetime. To improve the sensitivity of wireless sensor networks, an efficient scheduling algorithm and energy management technology for minimizing the energy consumption at each node is desired. ill this paper, we propose energy-aware routing mechanism for maximum lifetime and to optimize the solution quality for sensor network maintenance and to relay node from its adjacent cluster heads according to the node"s residual energy and its distance to the base station. Proposed protocol may minimize the energy consumption at each node, thus prolong the lifetime of the system regardless of where the sink is located outside or inside the cluster. Simulation results of proposed scheme show that our mechanism balances the energy consumption well among all sensor nodes and achieves an obvious improvement on the network lifetime. To verify propriety using NS-2, proposed scheme constructs sensor networks adapt to current model and evaluate consumption of total energy, energy consumption of cluster head, average energy dissipation over varying network areas with HEED and LEACH-C.

A Study of UHF RFID Metallic Tag Design for Long Reading Range Using a Cavity Structure (캐비티 구조를 사용한 장거리 인식용 UHF RFID 금속용 태그 설계에 관한 연구)

  • Lee, Jin-Seong;Lee, Kyoung-Hwan;Yeo, Jun-Ho;Chung, You-Chung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1468-1474
    • /
    • 2009
  • This paper shows an UHF RFID metallic tags using a Cavity structure for a long reading range. The reading range of a general passive tag is limited because the EIRP of a reader system is limited as 36㏈m by ISO 18000-6. To extend the reading range, the tag antenna should have a high gain antenna structure. The designed tag antenna is recognized over 10m range with a Cavity structure. The directivity pattern and the performance of the tag with the Cavity structure is stable when it is attached to a metallic object. The designed tag antenna has two kinds as cavity thickness. The sizes of designed tag antennas are $176\;{\times}\;52\;{\times}\;10\;mm$ and $176\;{\times}\;61\;{\times}\;30mm$ They can be attached to a large metallic materials and heavy equipments. The measured reading ranges of the tags are about 11m and 15m when they are attached to a metallic object.

Common Data Model for Network Analysis Applications of K-EMS (K-EMS 계통해석 어플리케이션을 위한 공통 데이터 모델 구축)

  • Yun, S.Y.;Cho, Y.S.;Lee, U.H.;Sohn, J.M.;Nam, Y.W.;Lee, J.;Kim, H.R.;Kim, B.H.;Kim, S.G.;Hur, S.I.;Lee, H.S.;Shin, M.C.;Min, K.I.;Choi, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.75-76
    • /
    • 2008
  • 본 논문에서는 한국형 에너지 관리 시스템의 계통 해석용 프로그램을 위한 공통 데이터 모델의 구축에 대해 다루었다. 공통 데이터 모델이란 다양한 어플리케이션이 공유하여 사용할 수 있는 계통 모델의 데이터베이스를 가리키며 본 논문에서는 토폴로지 프로세서(topology processor, TP), 상태추정(state estimator, SE), 급전원 조류계산(dispatcher power flow, DPF), 휴전계획(outage scheduler, OS), 부하 분포계수(bus load distribution factor, BLDF), 송전 손실 민감도 계수(transmission loss sensitivity factor, TLSF) 등을 위한 공통 모델에 대해 다루었다. 공통 모델의 구축을 위해 각 어플리케이션에서 필요한 정보를 수집하여 전력계통의 토폴로지 구조과 계통 설비를 모델링 하였다. 최종적으로 계층적(hierarchy) 구조와 비계층적(non-hierarchy) 구조로 나뉘어진 직접(direct) 및 간접(indirect) 인덱스 코드를 사용하여 데이터로의 빠른 접근이 가능한 실시간 데이터베이스 형태를 제시하였다.

  • PDF

Adaptive Garbage Collection Policy based on Analysis of Page Ratio for Flash Memory (플래시 메모리를 위한 페이지 비율 분석 기반의 적응적 가비지 컬렉션 정책)

  • Lee, Soung-Hwan;Lee, Tae-Hoon;Chung, Ki-Dong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.5
    • /
    • pp.422-428
    • /
    • 2009
  • NAND flash memory is widely used in embedded systems because of many attractive features, such as small size, light weight, low power consumption and fast access speed. However, it requires garbage collection, which includes erase operations. Erase operation is slower than other operations. Further, a block has a limited erase lifetime (typically 100,000) after which a block becomes unusable. The proposed garbage collection policy focuses on minimizing the total number of erase operations, the deviation value of each block and the garbage collection time. NAND flash memory consists of pages of three types, such as valid pages, invalid pages and free pages. In order to achieve above goals, we use a page ratio to decide when to do garbage collection and to select the target victimblock. Additionally, we implement allocating method and group management method. Simulation results show that the proposed policy performs better than Greedy or CAT with the maximum rate 85% of reduction in the deviation value of the erase operations and 6% reduction in garbage collection time.

An Energy Consumption Prediction Model for Smart Factory Using Data Mining Algorithms (데이터 마이닝 기반 스마트 공장 에너지 소모 예측 모델)

  • Sathishkumar, VE;Lee, Myeongbae;Lim, Jonghyun;Kim, Yubin;Shin, Changsun;Park, Jangwoo;Cho, Yongyun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.5
    • /
    • pp.153-160
    • /
    • 2020
  • Energy Consumption Predictions for Industries has a prominent role to play in the energy management and control system as dynamic and seasonal changes are occurring in energy demand and supply. This paper introduces and explores the steel industry's predictive models of energy consumption. The data used includes lagging and leading reactive power lagging and leading current variable, emission of carbon dioxide (tCO2) and load type. Four statistical models are trained and tested in the test set: (a) Linear Regression (LR), (b) Radial Kernel Support Vector Machine (SVM RBF), (c) Gradient Boosting Machine (GBM), and (d) Random Forest (RF). Root Mean Squared Error (RMSE), Mean Absolute Error (MAE) and Mean Absolute Percentage Error (MAPE) are used for calculating regression model predictive performance. When using all the predictors, the best model RF can provide RMSE value 7.33 in the test set.

Data Interworking Model Between DLMS and LwM2M Protocol (DLMS와 LwM2M 프로토콜 간 데이터 연동 모델 연구)

  • Myoung, Nogil;Park, Myunghye;Kim, Younghyun;Kang, Donghoon;Eun, Changsoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.29-33
    • /
    • 2020
  • Despite the same system architecture and operation principle, Advanced Metering Infrastructure (AMI) and Internet of Things (IoT) are recognized as a heterogeneous system. This is due to the different object modeling and communication protocols used in smart meters and sensors. However, data interworking between AMI and IoT is expected to be inevitable in the future. In this paper, we propose Device Language Message Specification (DLMS) to Lightweight Machine to Machine (LwM2M) conversion model. The proposed interworking model can reduce the packet size by 46.5% compared to that of the encapsulation method.

농업용수 시험지구 운영을 통한 용수이용 효율성 제고

  • 김진택
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.02a
    • /
    • pp.309-324
    • /
    • 2002
  • 국내의 경우 관개용수의 대부분은 벼생육을 위한 논의 관개응수로 사용되고있다. 농업용수 이용은 약 150억㎥/year, 이는 하천유지수량을 제외한 전체 물이용량 237억㎥/year의 약 63%에 해당한다. 최근 물절약은 가장 중요한 사회, 경제적인 이슈 중의 하나로 인식되고 있다. 그러나, 국내의 경우 관개효율은 여전히 낮아 약 35%의 관개용수가 손실되는 것으로 추정되고있다. 비록 관개에서의 물절약이 시급한 문제이기는 하지만 용수손실 원인에 따른 손실량에 대한 정량적인 연구가 행해지지 않았었다. 손실 원인에 따른 손실량을 계측하기 위한 시험지구로 경기 평택의 이동지구를 선정하였다. 시험지구의 주수원공으로는 유역면적 9,440ha, 관개면적 2,027ha인 이동저수지이며 상류유역에 미산 및 용덕저수지가 위치하고 관개지구내에 원암 및 은산양수장이 있다. 시험지구의 계측시설은 강우량 계측을 위하여 자기강우계를 설치하였고 저수위, 하천수위 및 응배수로의 수위 측정을 위하여 수위계를 설치하였다. 강우계는 4개소에 설치되었으며 수위계는 26개소에 설치되었다 강우계는 지구내의 저수지 및 양수장 관리사 부근 4개소에 전도형 자기우량계를 설치하였다. 수위계 26개소 중에서 저수지의 저수위 계측지점이 3개소이며 하천수위 계측지점이 2개소 그리고 용배수로의 간선수로 시점부와 간지선 분기점 등의 주요지점에 21개소의 계측지점이 있다. 모든 계측지점의 계측기에는 자체 혹은 별도의 자료저장용 데이터로거가 부착되어 현장 계측자료를 저장하도록 설치 되어있다. 강우계는 전도형강우계(tipping bucket type)이며 수위계는 계측지점의 특징에 따라 여러종류의 수위계측기가 설치되었다 예를들어 초음파수위계(ultrasonic-wave type), 부표식수위계(float type) 그리고 압력식수위계(Pressure type)가 설치되어 있다. 현장 계측기의 전원은 한국전력 전원 혹은 태양전지 및 축전지를 사용하였다. 수위계측지점의 유량을 환산하기 위하여 계측지점의 단면조사와 유속측정을 통해서 수위-유량관계(rating curve)를 규명하였다. 시험지구의 관개효율 및 용수손실 규명 등에 관한 기본자료를 수집하기 위해서는 계측시스템의 운영은 장기간으로 지속 되어야 한다

  • PDF

Distribution Remote Management System Design and Program Development Based on ADWHM(Advanced Digital Watt-Hour Meter) (차세대 디지털 적산전력계에 기반한 배전원격관리시스템 설계 및 프로그램 개발)

  • Ha Bok-Nam;Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.185-192
    • /
    • 2005
  • This paper proposes a DRMS(Distribution Remote Management System) which can enhance highly the economics of automatic metering system and the power quality supplied to the electric customer improving the efficiency of the meter reading, voltage management and load management work by realizing the remote meter reading, the remote voltage management and the remote load management based on the ADWHM(Advanced Digital Watt Hour Meter). The DRMS is designed so that the voltage management and load management work in remote site can be processed by collecting the voltage pattern and current pattern as well as watt hour data from all ADWHMs one time every month regularly or from special ADWHMS several time irregularly, A new on-line voltage and load management strategy based on the ADWHM is designed by analyzing the existing voltage management and load management process. Also, DRMS is designed so that watt-hour data, voltage pattern data, load pattern data and power factor data can be collected selectively according to the selection of user to assist effectively the methodology. Remote management program and database of the DRMS are implemented based on Visual C++, MFC and database library of MS. Also, DRMS is designed so as to communicate with the ADWHM using RS232C-TCP/IP converter and ADSL. The effectiveness of the remote metering function is proven by collecting and analyzing the data after ADWHMs installed in any site. The developed strategy and program also is verified through the simulation of voltage management and load management.

The Technique of Installing Floating Photovoltaic Systems (수상태양광의 시공기술에 관한 실증연구)

  • Choi, Young-Kwan;Yi, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4447-4454
    • /
    • 2013
  • In October 2011, a commercialized 100kW class floating photovoltaic system positive plant was installed at Hapcheon dam a multi-purpose reservoir the first time ever in the nation. Floating photovoltaic system differs in water float, mooring device and underwater cable process from land photovoltaic system. As for land and building photovoltaic power generation equipments, many installation cases and skilled experiences are available, and thus installation is not difficult. However, commercial power generation floating photovoltaic system, which is attempted for the first time in the nation, requires to be designed and installed through a series of processes like technical review and verification of data by process in comparison with similar cases. The structure of floating photovoltaic system, an equipment for float photovoltaic module and other electrical equipment, is required to withstand weather environments like wind or typhoon etc and yet not affect water quality negatively, and for implementation of this system, construction efficiency and economy etc should be considered comprehensively. In this paper, the techniques of installing floating photovoltaic structure, mooring device, underwater cable, electrical equipment and remote monitoring control system are explained. The 100kW floating PV system is operating with 15% average capacity factor.