• Title/Summary/Keyword: 전단기여

Search Result 150, Processing Time 0.025 seconds

Steel Fibers Efficiency as Shear Reinforcement in Concrete Beams (섬유보강콘크리트 보의 전단거동에 미치는 강섬유의 효과)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.118-128
    • /
    • 1994
  • There have been conducted a lot of works on shear behavior of steel fiber reinforced concrete beams. Fiber reinforced concrete beams without shear reinforcement were tested to determine their cracking shear strengths and ultimate shear capacities. Results of tests on 14 reinforced concrete beams (including 11 containing steel fibers) are reported. Two parameters were varied in the study, namely, the volume fraction of fibers and shear span-to-depth ratio.The effects of fiber incorporation on failure modes, deflections, cracking shear strength, and ul~imate shear strength have been examined. Resistance to shear stresses have been found to be improved by the inclusion of fibers, The mode of failure changed from shear to flexure when the shear span-to-depth ratio exceeds 3.4. Based on these investigations, a method of computing the shear strength of steel fiber reinforced concrete beam is suggested. The comparisons between computed values and expenmentally observed values are shown to verify the proposed theoretical treatment and steel fibers efficiency.

Shear Strength of PC-CIP Composite Beams with Shear Reinforcement (횡 보강된 프리캐스트와 현장타설 콘크리트 합성보의 전단강도)

  • Kim, Chul-Goo;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.189-199
    • /
    • 2014
  • Currently, in the precast concrete construction, Precast Concrete (PC) and Cast-In-Place (CIP) concrete with different concrete strengths are frequently used. However, current design codes do not specifically provide shear design methods for PC-CIP hybrid members using dual concrete strengths. In the present study, simply supported composite beams with shear reinforcement were tested. The test variables were the area ratio of the two concretes, spacing of shear reinforcement, and shear span-to-depth ratio. The shear strengths of the test specimens were evaluated by current design codes on the basis of the test results. The results showed that the shear strength of the composite beams was affected by the concrete strength of the compressive zone and also proportional to the flexural rigidity of un-cracked sections. Furthermore, the contribution of shear reinforcements varied according to the concrete strength of the compressive zone.

An Experimental Study on the Behavior of T-type Modular Composite profiled Beams (T형 모듈단면 합성 프로파일보의 거동에 관한 실험적 연구)

  • Ahn, Hyung Joon;Lee, Seong Won;Ryu, Soo Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.539-548
    • /
    • 2008
  • This study aims to determine the applicability of the previously published T-type modular profile beam in the manner of producing specimens designed specially for the said purpose, determining their bending and shear behaviors depending on the presence of shear reinforcement, and analyzing the results in comparison with the theoretical equation of plastic deformation. The modular profile beam contributes to bending and shear resistance with the addition of the profile to the form function, and enhances the molding performance through the modular concept. The experimental results showed that the TS series specimens with shear reinforcement have bending behaviors superior to those of the T series specimens without shear reinforcement, which suggests that the used shear reinforcement appropriately bears the shear force. However, it was considered that all the specimens except for the T1-1 specimen failed to have adequate bending performance because of the intermodular slipping caused by the shear failure of the bolts. It is expected that further studies on the T-type modular profile beam, in which shear connectors will be considered as a variable,be performed to develop optimal intermodular connection methods.

Nonlinear Analysis of Stress-strain for RC Panel Subjected to Shear (순수전단이 작용하는 RC Panel의 응력-변형률 비선형해석)

  • Cha, Young-Gyu;Kim, Hak-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.175-181
    • /
    • 2010
  • The three truss models(equilibrium truss model, Mohr compatibility truss model, and the soften truss model) based on a rotating angle is called the rotating-angle model. The three rotating-angle models have a common weakness: they are incapable of predicting the so-called "contribution of concrete". To take into account this "contribution of concrete", the modern truss model(MCFT, STM) treats a cracked reinforced concrete element as a continuous material. By combining the equilibrium, compatibility, and the softened stress-strain relationship of concrete in biaxial state, MTM is capable of producing the nonlinear analysis of reinforced concrete structures composed of membrane element. In this paper, an efficient algorithm is proposed for the solution of proposed model incorporated with failure criteria. This algorithm is used to analyze the behavior of reinforced membrane element using the results of Hsu test.

Evaluation of Shear Performance of Rectangular NRC Beam (직사각형 NRC 보의 전단성능 평가)

  • Lee, Ha-Seung;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.81-88
    • /
    • 2022
  • In the NRC (New paradigm Reinforced Concrete) beam, steel forms, main angles used as main reinforcements, and shear angles used as basic shear reinforcements are welded and assembled in the form of vierendeel truss structures in a steel factory. After the NRC truss frame is installed at the site, additional main reinforcement and shear reinforcement are distributed. In this study, the shear performance evaluation of the NRC beam was conducted through shear tests in accordance with the type of shear reinforcement of the NRC beam (shear angle, inclined shear reinforcing bar, and U-type cover bar). As a result of the test, the initial stiffness was similar before the initial cracking of each specimen, and all specimens were shear fractured.The shear reinforcements of the specimens exhibited a yielding behavior at the time of the maximum sheat force, and the shear strengths of the specimens increased as the amount of reinforcement of the shear reinforcement increased. These results show that NRC shear reinforcements exhibit shear performance corresponding to their shear strength contribution. As a result of calculating the nominal shear strengths according to KDS 14 20 22, the experimental shear strengths of the NRC beam specimens with shear reinforcement was 37~146% larger than the nominal shear strengths, so It was evaluated as a safety side.

Shear Performance on SFRC Beam Using Recycled Coarse Aggregate (순환골재를 사용한 SFRC 보의 전단성능)

  • Kim, Seongeun;Jeong, Jaewon;Kim, Seunghun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.189-196
    • /
    • 2018
  • Degraded shear performance of reinforced concrete members with recycled coarse aggregate (RCA) compared to flexural strength is a problem. To address this, steel fibers can be used as concrete reinforcement material. In this study, the strength and deformation characteristics of SFRC beams using RCA were to be determined by shear tests. Major experimental variables include the volume fraction of steel fiber (0, 0.5%, 1%), the replacement rate of RCA (0%, 100%), and the shear span ratio (a/d = 1, 2). As a result of the experiment, the shear strength of the specimen increased as the rate of mixing steel fiber increased. For specimens with RCA and 1% steel fiber, the maximum shear strengths increased by 1.77 - 6.25% compared to specimens with normal coarse aggregate (NCA). On the other hand, at 0-0.5% steel fiber, the shear strengths of RCA specimens were reduced by 24.2% to 49.2% compared to NCA specimens. This indicates that reinforcement with 1% volume fraction of steel fiber greatly contributes to preventing shear strength reduction due to the use of RCA.

A study on the selection of sensing locations for a high-rise building using displacement participation factor and strain energy density (변위기여도 및 변형에너지밀도를 활용한 고층 건물의 센싱 위치 선정에 관한 연구)

  • Lee, Hong-Min;Park, Sung-Woo;Park, Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.217-220
    • /
    • 2009
  • 고층 건물에 대한 구조 안전성 모니터링은 건물 특성상 계측 대상 부재가 많고 하중과 구조반응의 관계가 복잡하기 때문에 센싱 위치 선정의 어려움으로 그 적용에 한계가 있다. 본 논문에서는 고층 건물의 구조 건전도 모니터링을 위한 구조반응 계측위치를 선정하기 위해서 에너지 이론에 근거한 부재의 변위기여도 및 변형에너지밀도 개념을 도입하였다. 보, 기둥, 코어 전단벽, 그리고 아웃리거로 구성된 고층 건물을 대상으로 풍하중에 대한 부재 종류별 부재의 변위기여도 및 변형에너지밀도를 확인하고 전체 구조물의 거동과의 관계를 분석하여 고층 건물의 구조 건전도 모니터링을 위한 센싱 위치를 예상해보았다.

  • PDF

The Branching Effects of Pectic Polysaccharides on Viscoelastic Properties (펙틴 다당류의 측쇄가 점탄성에 미치는 영향)

  • Jozef L. Kokini
    • The Korean Journal of Rheology
    • /
    • v.7 no.2
    • /
    • pp.120-127
    • /
    • 1995
  • 중량비가 측쇄의 함량이 각각 4.37%(시료I)와 8.97%(시료II)인 두종류의 사과 펙틴을 이용하여 측쇄가 펙틴용액의 점탄성에 미치는 역할에 대하여 연구하였다. 시료II가 시료 I보 다 동일한 농도에서 더높은 전단속도에서는 오히려 시료 I의 전단점도가 시료 II보다 높은 값을 보였다. 시료I과 시료 II의 η0는 농도에 대하여 각각 η0 C4.23의 관계를보여 시료II가 더높은 농도의존성을 보였다. 한편 용액의 탄성특성을 나타내는 저장탄성계수(G')와 zero-shear recoverable compliance(Jeo)의 경우에는 시료II가 시료I보다 높은 값을 보였는데 이는 측쇄가 탄성과 밀접한 관계가 있다는 것을 의미한다. 펙틴용액의 전단점도와 복소점도 를 비교했을 때 거의 비슷한 값을 보였으나 예외적으로 고측쇄의 시료 II의 경우 고농도에 서 서로 상이한 값을 보였다. 본연구의 결과는 진한 용액하에서 측쇄가 분자간의 상호엉킴 에 상당한 기여를 하고 있음을 나타내었다.

  • PDF

The Distribution of Chironomids by Flow Mechanisms (흐름 메카니즘에 의한 깔따구들의 분포(I) - 실험)

  • Kim, Tae Won;Lee, Sang Ho;Lee, Kil Seong;Park, Jong Pyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.399-403
    • /
    • 2004
  • 생태 수리학적 측면에서 수질 개선에 기여하는 깔따구들이 흐름 구조에 따라서 어떻게 분포하는지를 파악하기 위해 수리 실험을 수행하였다. ADV로 유속을 측정하였으며, 자기 다른 유속 조건하에서 유기물질과 깔따구들을 투입하였다. 취득한 유속자료를 이용하여 흐름구조를 파악하였으며, 난류특성인 난류 전단응력을 분석하였다. 유기물질과 깔따구들은 상대적으로 유속이 느리고 전단응력이 작게 나타나는 지점에 분포하였다. 깔다구들이 굴을 파고 서식을 하였더라도 흐름에 의해 서식처가 옮겨짐을 확인 하였으며, 서식처 역할을 할 수 있는 반구 구조물 주위에 서식하였다. 유기물질의 퇴적 및 깔따구들의 서식은 주로 흐름 방향 유속 분포에 영향을 받으며, 이차류도 이것들의 분포에 중요한 역할을 하고 있다.

  • PDF

Structural Behavior of Reinforced Concrete Beam Strengthened in Shear by Carbon Fiber Mesh and Mortar (탄소섬유메쉬와 모르터로 전단 보강된 RC보의 거동에 관한 연구)

  • Seo, Soo-Yeon;Yoon, Seung-Joe;Lee, Woo-Jin;Lee, Jong-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.205-211
    • /
    • 2004
  • The purpose of this study is to investigate shear strengthening effects and behaviour of RC beams strengthened in shear by Carbon Fiber Mesh(CFM) and mortar for fixing CFM to concrete. Test parameters in experiment are shear span-to-depth ratio, layout of CFM and number of clip. From the test, it was shown that the governing failure patten was the bond failure between cover mortar and RC beam initiated at about 60% of maximum strength. And the strength of CFM was developed up to 19.6% of it's maximum tensile strength when the specimen reached to failure. The most effective enhancement using CFM and mortar were to attach CFM diagonally to concrete in a/d of 1.0 and increase the number of cilps in a/d of 1.5, respectively.