• Title/Summary/Keyword: 전기IT

Search Result 23,959, Processing Time 0.044 seconds

The effect of the process parameters on the electrical properties of Ni/Cr/Al/Cu alloy thin film (공정변수에 의한 Ni/Cr/Al/Cu계 박막의 전기적 특성)

  • 이붕주;박상무;박구범;박종관;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.725-728
    • /
    • 2001
  • We have fabricated thin films using the DC/RF magnetron sputtering of 74wt%Ni-l8wt%Cr-4wt%Al-4wt%Cu alloy target and studied the effect of the process parameters on the electrical properties for low TCR(Temperature Coefficient of Resistance) films. In sputtering process, pressure, power and substrate temperature, are varied as controllable parameter. The films are annealed to 400$^{\circ}C$ in air and nitrogen atmosphere. The sheet resistance, TCR of the films increases with increasing annealing temperature. It abruptly increased as annealing temperature increased over 300$^{\circ}C$ in air atmosphere. From XRD, it is found that these results are due to the existence of NiO on film surface formed by annealing. As a results of them, TCR can be controlled by variation of sputter process parameter and annealing of thin film.

  • PDF

A study on Fabrication of Harden Carbon for Electrical Application (전기재료장 경질탄소 제조에 관한 연구)

  • 지명학;임대영;김종옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.198-201
    • /
    • 1995
  • Carbons are the materials which are known to be usable at highest temperature in existing materials and are being increased their mechanical Properties to 2000$^{\circ}C$. They have many advantageous characteristics such as electrical and thereat conductivity. But, inspire of their properties, this materials have covalant bonding that strong1y link their atoms. the covalant bondings are too strong to occur atomic diffusions or shirinkages during the sintering. because of this sintering mechanism, carbon materials must be produced by using some binders. To obtain a good carton material, it is important that the function of binders. And to obtain a good binder, it reqired the additive which can improve the properties of the binder, so called curing agent. In this study, we make a curing agent that can improve the properties of binders to evaluate the yield of carbon from binders and to shirink the substrate. and compared the carbon materials treated with the binder containing the curing agent to that treated with common binder.

  • PDF

A study on algorithm of AT feeding systems (AT 급전계통 전기철도 해석 알고리즘 연구)

  • Choo, Dong-Woog;Kim, Jae-Chul;Kim, Nak-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1226-1228
    • /
    • 2001
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train were proposed. To obtain terminal voltage of train by using equivalent circuit of the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the case study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.

  • PDF

Optimal Location of RC bank limiting Harmonics in Electric Railway System (전기철도 급전계통의 고조파 억제용 RC뱅크의 적정 위치에 관한 연구)

  • Lee, H.M.;Oh, K.H.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1254-1256
    • /
    • 2001
  • This paper composes the Electric Railway System with the common grounding based on the 5-port network model. We compare the magnification ratio of harmonic currents according to locations of RC bank(i.e s/s. sp, and pp). It takes a lot of costs to equip the RC-bank at all location. And it is NOT effective that RC-bank is equipped at S/S. Finally, this paper proposes SP as the optimal site of RC-bank aspect reducing harmonic.

  • PDF

Electrical and Chemical characteristics of Zn(II)-Porphyrin Langmuir-Blodgett(LB) Films (Zn(II)-Porphyrin LB막의 전기, 화학적 특성에 관한 연구)

  • Koo, Ja-Ryong;Lee, Ho-Sik;Kim, Young-Kwan;Kim, Jung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.752-755
    • /
    • 2002
  • Since Metallo-Porphyrin (MP) is very interesting compound due to its unique electronic and redox properties and it is also chemically and thermally stable, MP has been studied for potential memory and switching devices. In this study, thin films of 5,10,15,20 - Tetrakis - Octadecyloxymethylphenyl - Porphyrin - Zn(II) (Zn-TPP) were prepared by the Langmuir-Blodgett (LB) method and characterized by using UV/vis absorption spectroscopy and cyclic voltammetry. It was found that the proper transfer surface pressure for film deposition was 25 mN/m and the limiting area per molecule was $135{\AA}^2$/molecule. The current-voltage (I-V) characteristics of these films were investigated.

  • PDF

COMPUTERIZED CALL RESPONSE SYSTEM DEVELOPMENT AND OPERATION FOR DISTRIBUTION SERVICES (전기고장접수 처리 자동화장치 개발운용)

  • Lee, Yong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.265-269
    • /
    • 1989
  • Computerized to techniques have been applied to outage call processing system for rapid restoration of power to customers. This paper presents computer aided outage call processing system called '123' system, which has been in operation since 1987. And, also describes its origins, design conception to be considered and its operation effects. From a positive point of view, it shows the functions needs to be added and some problems to be improved. Additionally, it describes the integrated system which has functions of detecting distribution failure, locating failure position by logical computer processing, and although ADS (Automatic Distribution System) has yet to be built up, the primary purpose of the system is to improve service to the customer by means of rapid restoration of electricity outage.

  • PDF

Experimental investigation of electric currents flowing through human body in electirc shock (전기충격시인체에 흐르는 전류의 실험적 고찰)

  • 김완배;안광윤;윤태원
    • 전기의세계
    • /
    • v.29 no.1
    • /
    • pp.21-27
    • /
    • 1980
  • The effect of electric shock on human body is enormousness, which leads to warmth, tingling, and even death. The mean values of perception currents obtained on 91 men and 39 women are about 0.77(mA) for men and 0.57(mA) for women. The mean value for women is approximately seven tenths that of men. An individual can tolerate, with no adverse effects, repeated exposure to the reactions associated with currents of his let-go level, and the mean value of let-go currents obtained from 27 normal men is 6.29(mA). Lethal currents flowing human body is very dangerous even for a short time. So, it is necessary to have recourse to animal experiments ot determine lethal current for human. An analysis of experimental data indicates that body weight and shock duration are important factors in determining the lethal current. It is suggested that the relationship between current and shock duration is given by I=K/.root.T, and lethal current is proportional to body weight, where I is the current in milliampere, and T is the time in seconds.

  • PDF

Luminance Control for a Given Gray Level by the Asymmetric Sustain Pulse Amplitude in AC PDP (주어진 계조 하에서 불평형 서스테인 펄스를 이용한 AC PDP의 휘도제어)

  • Lee Sun-Hong;Park Chung-Hoo;Choi Joon-Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.161-165
    • /
    • 2005
  • Need of a dimmer function becomes more important with increasing interest on a HDTV for home theater applications. In a conventional AC PDP, a possible method to reduce luminance of a whole Panel is to reduce a total number of sustain pulses and then to change the gray level. However, the reduction of the total sustain number causes the step of luminance to be rough. Moreover, it is impossible to control the luminance of the panel for a given gray level. In this paper, a simple and robust method is proposed to control linearly the luminance of whole panel by applying the asymmetric sustain pulses in the display period of the ADS driving scheme. As the range of luminance control by the proposed method is about $50\%$ for a given gray level. Moreover, it is experimentally verified that the proposed method shows similar dynamic margin performances compare with the conventional method.

A Pulse Power Supply for Metal Vapor Lasers (금속 증기 레이저용 펄스 전원 장치)

  • Cha Byung Heon;Lee Heung Ho;Jin Jeong Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.190-197
    • /
    • 2005
  • A reliable and compact pulse power supply using a thyratron and a magnetic pulse compression (MPC) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a conventional thyratron-discharge type pulse power supply. A thyratron generated a long pulse of its conduction pulse width 500 ns and then it was compressed to less than 80 ns of its output voltage rise time by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 30 mm inner diameter and 1.5 m discharge length. It was operated several hundreds hours without any troubles.

A Study Algorithm of AT Feeding Systems (AT 급전계통 해석 알고리즘 연구)

  • Chu, Dong-Uk;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.174-179
    • /
    • 2002
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train system were proposed. To obtain terminal voltage of train by using equivalent circuit or the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the carte study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.