• Title/Summary/Keyword: 전기-열해석

Search Result 379, Processing Time 0.032 seconds

A Study on the Thermal Analysis of Induction Motors (유도 전동기의 열해석에 관한 연구)

  • Chun, Jang-Sung;Kim, Hyung-Sup;Lee, Cheol-Gyun;Won, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.961-964
    • /
    • 1993
  • The evaluation of the temperature of the motor in operation is necessary for smaller and lighter design of motors and for the determination of insulation class. The exact loss distribution modelling is absolutely necessary for the enact evaluation of the temperature. We calculated the temperature exactly by considering the loss distribution dependent on temperature. The comparison between the calculated results and the experiments is performed to verify the validity of the analysis.

  • PDF

The coupling field analysis of a thermal transfer phenomenon by an magnetic field (자계 분포시 열유동 현상 분석을 통한 결합계 해석)

  • Son, Rak-Won;Jang, Kwang-Yong;Bae, Jae-Nam;Kim, Sung-Ju;Choi, Sung-Gil;Ju, Lee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.862-863
    • /
    • 2007
  • In this article, we researched the characteristics of heat transfer of the bimetal for over-current protection device. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the heat transfer characteristics, by using a bimetal which has a single metal, we analyzed the temperature distribution when bimetal acts a switch. As usual, heat source is applied to the bimetal. But, in the over-current protection switch, the current become heat source. So, by using the current as source, we performed the magnetic analysis and thermal analysis together.

  • PDF

An Evaluation of Phase Array Influence using EMTDC (EMTDC를 이용한 송전선로 상배열 영향평가)

  • Han, Jeong-Yeol;Chang, Byung-Hoon;Yoon, Jong-Su;Kim, Soo-Yeol;Moon, Seung-Pil
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.483-484
    • /
    • 2007
  • 신설 선로와 기존 선로와의 계통 연계시 상 배치에 따라 연계 후 정상상태에서 과다한 영상전류의 발생으로 인하여 지락계전기의 동작 같은 계통에 악 영향을 미치는 현상이 일어난다. 이 논문은 새로운 계통연계 시 송전선로의 기설된 철탑을 이용한 역상배치 시행여부에 따른 실 계통을 해석하고 계통의 상시 불평형률을 간의 선로 신설 공사와 관련하여 분석하여, 이상적인 송전선로 상 배열을 제시한다.

  • PDF

Analysis and Optimal Design of Optical Pickup Actuator by 3-D EMCN method (3D-EMCN범을 이용한 광 픽업 엑츄에이터의 해석 및 최적설계)

  • Kim, Gin-A;Chung, Tea-Kyung;Choi, In-Ho;Hong, Sam-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.12-14
    • /
    • 2001
  • In this paper, three dimensional Equivalent Magnetic Circuit Method(3-D EMCN method), a numerical analysis method which supplements to magnetic equivalent circuit adding numerical technique, is proposed for analysis Optical Pickup Actuator. [3] This method provides better characteristics both in precision of the analysis and in computation time than other analysis method such as three-dimensional Finite Element Method. RCS Niching Genetic Algorithm are used for optimal design.

  • PDF

On Singularities of SISO Nonlinear Systems (단일 입출력 비선형시스템의 특이점의 성질에 관한 연구)

  • Jin, Ju-Wha;Cho, Seong-Il;Jung, Soo-Yul;Seo, Joong-Eon;Shin, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.1938-1939
    • /
    • 2001
  • 시스템을 입력과 출력간의 함수관계로 볼 때 출력에 대한 상대차수가 정의되지 않는 점을 특이점이라고 정의할 수 있다. 본 논문에서는 적절한 기하학적 조건을 만족하는 해석적인 시스템(analytic system)에 대하여 그러한 특이점의 성질을 살펴본다. 특이점을 지나는 궤적은 특이점의 특이도와 그에 관련된 함수 값의 부호에 의해서 특이점의 주변에서는 특이 매니폴드를 기준으로 한 영역에서 나머지 다른 영역으로 통과하거나 혹은 그를 기준으로 어느 한 쪽의 영역에만 머물러 있게 됨을 보임으로써 특이점과 이를 지나는 궤적의 상관관계를 명확히 규명하였다.

  • PDF

Analysis on Overvoltage induced on Power Distribution line by Lightning surge (배전선로의 유도뢰 해석)

  • Kim, H.J.;Choi, S.Y.;Jung, H.S.;Shin, M.C.;Park, N.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.279-281
    • /
    • 1998
  • This paper present overvoltage induced on distribution power line by lightning surge. It is important problem that overvoltage threatens credit and security of the power system. In this paper induced overvoltage was calculated. From the line being modeled in really actual practice. Also, the proper suppressing effects of a surge arrester against lightning induced voltages were suggested.

  • PDF

Effect of Microporous Structure of Al2O3/PVdF_HFP Ceramic Coating Layers on Thermal Stability and Electrochemical Performance of Composite Separators for Lithium-Ion Batteries (Al2O3/PVdF_HFP 세라믹코팅층의 미세기공구조가 리튬이차전지용 복합분리막의 열 안정성 및 전기화학특성에 미치는 영향)

  • Jeong, Hyun-Seok;Kim, Kyu-Chul;Lee, Sang-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.324-328
    • /
    • 2009
  • The internal short-circuit between cathodes and anodes has been known to be a critical concern for the safety failures of lithium-ion batteries, which is strongly influenced by the thermal stability of separators. In this study, to effectively suppress the internal short-circuit failures, we developed a new composite separator with the improved thermal stability compared to conventional polyolefin-based separators. The composite separators were prepared by introducing a ceramic coating layer ($Al_2O_3$/PVdF-HFP) onto both sides of a polyethylene (PE) separator. The microporous structure of ceramic coating layers is determined by controlling the phase inversion of coating solutions and becomes more developed with the increase of nonsolvent (water) content. This structural change of ceramic coating layers was observed to greatly affect the thermal stability as well as the electrochemical performance of composite separators, which was systematically discussed in terms of phase inversion.

Predictions of the Cooling Performance on an Air-Cooled EV Battery System According to the Air Flow Passage Shape (공기 유로 형상에 따른 공랭식 전기자동차 배터리 시스템의 냉각 성능 예측)

  • Jeong, Seok Hoon;Suh, Hyun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.801-807
    • /
    • 2016
  • This paper aims to compare and study the cooling performance of a battery system in accordance with the inlet and outlet geometry of the air passage in an EV. The arrangement and the heat source of the battery module were fixed, and the inlet/outlet area and its geometry were varied with the analysis of the cooling performance. The results of this study provide suggestions for the air flow stream line inside of a battery, the velocity field, and the temperature distributions. It was confirmed that the volume flow rate of air should be over $400m^3/h$, in order to satisfy conditions under $50^{\circ}C$, which is the limit condition for stable operation. It was also revealed that the diffuser outlet geometry can improve the cooling performance of battery system.

Numerical Modeling of Anodic Reaction of Carbon-Rich Fuel at Solid Oxide Fuel Cell (탄소연료를 이용하는 고체 산화물 연료전지의 연료극 반응 수치해석)

  • Lim, Ho;Kim, Jong-Pil;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.188-194
    • /
    • 2010
  • Direct Carbon Fuel Cell(DCFC), unlike gas turbines or engines, is a kind of fuel cell which directly generates electricity by electrochemical reaction from a carbon fuel. The advantages of DCFC are higher efficiency and lower emission in comparison with existing power generation facilities. In this study, the effects of CO and $CO_2$ on theoretical potential are examined using the thermodynamic equilibrium method, and the dependence of product on operating temperature is examined via two dimensional CFD method. As a result, when the reaction of CO production (Boudouard reaction) considered, theoretical potential is higher than that in only $CO_2$ reactions, and its value increases as temperature increases. Two dimensional results of computational fluid dynamics(CFD) confirm that the Boudouard reaction becomes more important to be considered as temperature increases and inert gas affects the equilibrium composition of the Boudouard reaction.

Development of Heating Device Using Concentrator Solar Cells (집광형 태양전지를 이용한 난방장치 개발)

  • Lee, Dong Il;Baek, Seung Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • In this study, the generation efficiency of the limited area of a concentrator solar cell was increased by using a solar concentrator and a tracking device. Heat generated by the solar cell was collected using a thermal absorber for supplying hot water or heating. Thus, the concentrator solar cell system provided electricity and heat simultaneously. Tracking of the sun by detecting the sun's position, repositioning of heating device towards the east after sunset, and shutting down of system after sunset were successfully implemented using an illuminance sensor (CdS) and Simulink, a commercial software package. We performed parametric analysis of the velocity, fin installation, and entrance location with respect to the operating temperature of the concentrator solar cell. A heat transfer simulation model was developed for comparing the actual temperature profiles of the concentrator solar cell and thermal absorber, and good agreement was found between the results of the simulations and the experiments.