• Title/Summary/Keyword: 전기화학 센서

Search Result 351, Processing Time 0.019 seconds

Electrocatalytic activity of the bimetallic Pt-Ru catalysts doped TiO2-hollow sphere nanocomposites (Pt-Ru@TiO2-H 나노구조체촉매의 합성 및 전기화학적 특성평가)

  • Lee, In-Ho;Kwen, Hai-Doo;Choi, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.42-50
    • /
    • 2013
  • This paper describes the electrocatalytic activity for the oxidation of small biomolecules on the surface of Pt-Ru nanoparticles supported by $TiO_2$-hollow sphere prepared for use in sensor applications or fuel cells. The $TiO_2$-hollow sphere supports were first prepared by sol-gel reaction of titanium tetraisopropoxide with poly(styrene-co-vinylphenylboronic acid), PSB used as a template. Pt-Ru nanoparticles were then deposited by chemical reduction of the $Pt^{4+}$ and $Ru^{3+}$ ions onto $TiO_2$-hollow sphere ($Pt-Ru@TiO_2-H$). The prepared $Pt-Ru@TiO_2-H$ nanocomposites were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), and elemental analysis. The electrocatalytic efficiency of Pt-Ru nanoparticles was evaluated via ethanol, methanol, dopamine, ascorbic acid, formalin, and glucose oxidation. The cyclic voltammograms (CV) obtained during the oxidation studies revealed that the $Pt-Ru@TiO_2-H$ nanocomposites showed high electrocatalytic activity for the oxidation of biomolecules. As a result, the prepared Pt-Ru catalysts doped onto $TiO_2$-H sphere nanocomposites supports can be used for non-enzymatic biosensor or fuel cell anode electrode.

Study on Porous Silicon Sensors to Measure Low Alcohol Concentration (저농도 알코올 측정을 위한 다공질 실리콘 센서에 관한 연구)

  • Kim Seong-Jeen
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.130-133
    • /
    • 1999
  • In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to apply for breath alcohol measurement and its characteristics are estimated at room temperature. Current alcohol sensors using metal oxides such as tin-oxide are not only difficult to measure low alcohol concentration, but also should heat at $200\;to\;400^{\circ}C$ to improve the sensitivity. But the sensor using porous silicon layer has good sensitivity even at room temperature by very large effective surface area and suitable structure to fabricate integrated micro sensors. In the experiment, the capacitance was measured for the range of 0 to $0.5\%$ alcohol concentration with the interval of $0.05\%$, in which alcohol solution was kept at 25, 36, and $45^{\circ}C$ by a heater. As the result, good linearity was observed and the capacitance increased about 1.1, 2.6 and $4.6\%$ per the increment of $0.1\%$ alcohol concentration each temperature, respectively, at the frequency of 120 Hz.

Electrochemical Determination of GABA using a 3-D Nanoporous Gold Thin Film (3차원 구조의 다공성 금 박막을 이용한 GABA의 전기화학적 측정)

  • Pyo, Su-Hyun;Lee, Jin-Ho;Oh, Byeung-Keun
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.575-578
    • /
    • 2011
  • We fabricated a novel simple and rapid method of three dimensional nanoporous gold thin film (NPGF) onto a Au substrate using electrochemical deposition method. The NPGF-modified electrode analysis by scanning electron microscope and reveals the formation of nanopores, approximately 30~50 nm in diameter. differential pulse voltammetry was measured for the determination of ${\gamma}$-aminobutiric acid in the concentration range of ($10{\sim}100{\mu}M$ using a NPGF. The high sensitivity feature of NPGF is expected to be applied for real sample biosensor applications.

Development of Voltammetric Nanobio-incorporated Analytical Method for Protein Biomarker Specific to Early Diagnosis of Lung Cancer (폐암 조기 진단을 위한 단백질 바이오마커 측정용 전압-전류법 기반의 나노바이오 분석법 개발)

  • Li, Jingjing;Si, Yunpei;Nde, Dieudonne Tanue;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.461-466
    • /
    • 2021
  • In this article, a portable and cost-effective voltammetric biosensor with nanoparticles was developed for the measurements of heterogeneous nuclear ribonucleoprotein A1 protein (hnRNP A1) biomarker which can potentially be used for lung cancer diagnosis. Gold nanoparticles were first electrodeposited onto screen printed carbon electrode (SPCE) followed by immobilizing a single stranded DNA aptamer specific to hnRNP A1 onto the electrode surface. Ethanolamine was also used when immobilizing DNA aptamer on the surface to prevent signals from non-specific adsorption events. Sequential injection of hnRNP A1 biomarker and anti-hnRNP A1 conjugated with alkaline phosphatase (ALP) onto the aptamer chip surface allows to form the sandwich complex of DNA aptamer/hnRNP A1/ALP-anti-hnRNP A1 on the electrode surface which further reacted with 4-aminophenyl phosphate (APP). The electrocatalytic reaction of the enzyme, ALP, and the substrate, APP, resulting in the oxidative current response changes at -0.05 and -0.17 V (vs. Ag/AgCl) against the hnRNP A1 concentration was measured using cyclic and differential pulse voltammetry, respectively. The Au nanoparticles-integrated voltammetric biosensor was applied to analyze human normal serum solutions possibly suggesting potential applicability for lung cancer diagnosis.

Electrochemical Behavior of UCl3 and GdCl3 in LiCl-KCl Molten Salt (LiCl-KCl 고온 용융염 내 UCl3 및 GdCl3의 전기화학적 거동 연구)

  • Min, Seul-Ki;Bae, Sang-Eun;Park, Yong-Joon;Song, Kyu-Seok
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.3
    • /
    • pp.276-281
    • /
    • 2009
  • Electrochemical behaviors of $U^{3+}$ and $Gd^{3+}$ were investigated in LiCl-KCl eutectic molten salt by using various electrochemical techniques. The electrodeposition and dissolution currents for uranium show the maximum at -1.51V and -1.35V, respectively while, for gadolinium,at -2.15V and -1.9V, respectively. In case of LiCl-KCl molten salt containing both of $U^{3+}$ and $Gd^{3+}$, the peak potential of electrodeposition of gadolinium shifts to more positive potential than in the solution without $U^{3+}$. The potentials in chronopotentiometric data suddenly dropped to negative value as soon as the reduction currents were applied and became constant at the potential around which the $U^{3+}$ and $Gd^{3+}$ are electrodeposited. The results of normal pulse voltammetry (NPV) and square wave voltammetry show that those methods can be used to qualitatively analyze the elements in the melts. Especially, the differentiation of NPV result was found to be useful for the separation of the peaks of which potentials are close each other.

Introduction of Various Amine Groups onto Poly(glycidyl methacrylate)-g-MWNTs and their Application as Biosensor Supports (폴리(글리시딜 메타크릴레이트)가 그래프트된 다중벽 탄소나노튜브에 다양한 아민 그룹의 도입과 바이오센서 지지체로서의 응용)

  • Chung, Da-Jung;Kim, Ki-Chul;Choi, Seong-Ho
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.470-477
    • /
    • 2012
  • A tyrosinase-immobilized biosensor was developed based on various amine-modified multi-walled carbon nanotube (MWNT) supports for the detection of phenolic compounds. MWNTs with various amine groups were prepared by radiation-induced graft polymerization of glycidyl methacrylate (GMA) onto MWNT supports and the subsequent amination of poly(GMA) graft chains. The physical and chemical properties of the poly(GMA)-grafted MWNT supports and the aminated MWNT supports were investigated by SEM, XPS, and TGA. Furthermore, the electrochemical properties of the prepared tyrosinase-modified biosensor based on MWNT supports with amine groups were also investigated. The response of the enzymatic biosensor was in the range of 0.1-0.9 mM for the concentration of phenol in a phosphate buffer solution. Various parameters influencing biosensor performance have been optimized: binder effects, pH, temperature, and the response to various phenolic compounds. The biosensor was tested on phenolic compounds contained in two different commercial red wines.

Chemical Sensors Using Polymer/Graphene Composite and The Effect of Graphene Content on Sensor Behavior (고분자/그래핀 복합재료의 센서 응용 및 그래핀 함량이 센서 거동에 미치는 영향)

  • Bae, Joonwon
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.25-29
    • /
    • 2020
  • In this study, a polymer/graphene hybrid composite was prepared by a simple roll-method and a simple sensor was produced by a convenient surface engineering procedure. The sensor performance was examined and the effect of graphene content on the sensing behavior was monitored. A polymer (polydimethylsiloxane, PDMS) paste containing graphene powder was prepared by a three-roll apparatus and polymer/graphene hybrid composite was produced by a two-roll technique. The sensing medium, cyclodextrin (CD) was introduced by a convenient bio-conjugation method. The efficacy of surface modification was confirmed by FT-IR spectroscopy and the ohmic relation was observed on composite surfaces. An analyte (e.g., methyl paraben, MePRB) at a 10 nM concnetration could be detected. When the graphene loading was low, the sensor performance was relatively poor. This was attributed to the absence of graphene alignments, which were observed for the composites having a high graphene loading. This indicates that the sensor performance was influenced by physical alignments of the filler. This article can provide important information for future research on developing sensing devices.

Biosensor Electrode Manufacturing Technology Using Nano-carbon Materials (나노 탄소물질을 이용한 바이오센서 전극제조 기술)

  • Kim, Ji-Hyun;Bae, Tae-Sung;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Due to human life expectancy of the recent development of medical technology recently, it leads to increase the desire for improving the quality of human life, and grow health concerns and needs. Therefore, in order to prevent the occurrence of disease and to check up a disease quickly, research on the development of a biosensor has been actively processed. One of them, the nano-carbon materials, are very suitable for manufacturing biosensor due to their excellent electrical/mechanical properties. In this review, we introduced the recent studies about preparation methods of carbon electrodes using the carbon nano-materials for biosensors as well as its technological applications.

Vacuum packaging of MEMS (Microelectromechanical System) devices using LTCC (Low Temperature Cofired Ceramic) technology (LTCC 기술을 이용한 MEMS 소자 진공 패키징)

  • 전종인;최혜정;김광성;이영범;김무영;임채임;황건탁;문제도;최원재
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.195-198
    • /
    • 2002
  • 현재의 광통신, 이동통신 및 디지털 시대에서는 보다 소형화되고, 대용량의 데이터 저장 및 다기능 소자에 대한 요구가 많아지고 있다. 이러한 전자 산업 환경에서 MEMS 소자는 여러 요구조건을 만족시킬 수 있는 특징을 갖추고 있으며 실제 소자의 제작에 있어서 MEMS 소자를 이용하여 여러 물리 및 화학 센서 및 Actuator 제작에 응용이 되어지고 있고 Optical switch, Gyroscope, 적외선 어레이 센서, 가속도 센서, 위치 센서 등 여러 분야에서 실용화가 진행되어지고 있다. MEMS 구조물의 packaging 방법에 있어서는 내부 MEMS 소자의 동작을 위한 외부 환경으로부터의 보호를 위하여 Hermetic sealing에 대한 요구를 만족시켜야 한다. 본 발표에서는 이와 같은 MEMS device의 진공 패키지를 구현함에 있어서 기판 내부에 수동소자를 실장할 수 있는 LTCC 기술을 이용하여 진공 패키징하는 방법에 대하여 소개한다. 본 기술을 이용하는 경우 기존의 Hermetic sealing 이외에 향후 적층 기판 내부에 수동소자를 내장시켜 배선 길이 및 노이즈 성분을 감소시켜 더욱 전기적 성능을 향상시킬 수 있는 장점이 있게된다. 본 논문에서는 LTCC 기판을 이용하여 패키징 시킨 후, 내부 진공도에 영향을 줄 수 있는 계면들에서의 시간에 따른 진공도 변화의 특성치를 측정하여 LTCC 기판의 Hermetic sealing 특성에 관하여 조사하였다.

  • PDF

Electrochemical Properties of Tobacco Peroxidase Incorporated Enzyme Electrode Bound with CSM Rubber (CSM 고무로 결합된 담배 과산화효소 고정 효소전극의 전기화학적 특성)

  • Yoon, Kil Joong
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.538-543
    • /
    • 2014
  • In order to substitute for the marketed horseradish peroxidase, a hydrogen peroxide sensor embedded with tobacco leaf in carbon pastes was constructed and its sensing ability was electrochemically evaluated. Ten and more electrode parameters obtained implied that the enzyme electrode exerts its remarkable specificity quantitatively in the experimental range of potential. Especially the small symmetry factor (${\alpha}$, 0.21) showed that the electrode kinetics is very sensitive to the change of electrode potential. The experimental facts above suggested that our enzyme electrode functions as a hydrogen peroxide sensor normally and tobacco peroxidase can be used in the place of the marketed one as an alternative to marketed ones.