• Title/Summary/Keyword: 전기절연파괴

Search Result 590, Processing Time 0.037 seconds

Surface Discharge Characteristics for Epoxy Resin in Dry-Air with Variations of Electrode Features and Epoxy Resin Size (Dry-Air 중의 전극 형상 및 에폭시수지의 크기변화에 따른 연면방전특성 연구)

  • Park, He-Rie;Choi, Eun-Hyeok;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.154-160
    • /
    • 2009
  • This paper shows a basic data of the surface discharge characteristics for epoxy resin in Dry-Air as being focused on environmentally friendly insulating Gas. Used electrodes are needle to plane, sphere to plane and KS M3015 electrodes. With the changing electrodes in same condition, we can obtain different creeping lengths, surface discharge voltages and surface dielectric strengths, respectively. Surface dielectric strengths of Needle to plane electrodes are more higher than the others. Moreover, it is considered that the surface discharge characteristics with variation of epoxy resin thickness and diameter. Surface discharge voltage increases as the thickness and the diameter of epoxy resin.

Evaluation of Insulation properites of Nano-filler XLPE (나노 충전제를 첨가한 XLPE의 절연 특성 평가)

  • Cho, Sung-Hoon;Kim, Yu-Min;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1519-1520
    • /
    • 2011
  • XLPE는 절연성 및 기계적, 열적 특성이 양호하여 1980년대부터 지중배선용 전력케이블의 절연재료로 사용되었다. 현재는 원재료의 성능 개선과 제조기술의 향상에 힘입어 초고압 교류 송배전 케이블용 절연재료로 적용 되고 있다. 절연파괴 강도에 대한 검토는 송전용량의 증대 및 초고압화가 가속됨에 따라 고전계하에서의 장기적인 절연성능을 좌우하는 중요한 요소이며, 절연 열화 현상을 진단하는 방법으로도 이용되고 있다. 본 연구에서는 HVDC용 나노복합 XLPE의 절연재료 평가기술 개발의 기초연구로써 최적의 나노 복합 재료를 확인하기 위하여 제작된 시편들의 전기적 특성 및 열적 특성을 평가하고자 한다.

  • PDF

절연매체로서의 $SF_{6}$가스

  • 곽영순
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.344-348
    • /
    • 1980
  • $SF_{6}$가스의 절연파괴특성 및 화학적특성에 관한 것을 종합해보면, 첫째, $SF_{6}$의 방전은 1개의 전자 avalanche중의 전자수가 임계치 Norit가 $10^{8}$정도에서 streamer에의 전이가 일어나므로서 이루어지며, 둘째, $SF_{6}$의 (.alpha.-.eta.)/.rho.와 E/.rho.의 관계는 .alpha.=.eta.근방에서 직선으로 상승되어 절연파괴에 극히 중요한 뜻을 가지며, 셋째, 두번째의 .alpha.=.eta.에 있어서의 구배는 보통의 기체보다 수 10배크기 때문에 최대전계를 부여하는 전극근방만이 공극의 방전개시를 지배하며, 넷째, 전기기구에 있어서 $SF_{6}$가스의 화학적변화의 energy원으로서는 arc, corona, 열을 들 수 있으며 특히 $SF_{6}$가스중과 공기중과의 내 Corona성을 구하기 위한 인가전압일내 Corona수명시간은 $SF_{6}$가스중이 공기중보다 길다는 것이다.

  • PDF

공기-절연유복합유도체의 절연파괴현상에 관하여 1

  • Chul Je Cho
    • 전기의세계
    • /
    • v.23 no.3
    • /
    • pp.60-66
    • /
    • 1974
  • This paper is to study on the phenomena that the compound dielectric strength through double layers of air-insulating oil dielectrics is much lower than that of air dielectrics only. the change of the dielectric strength by the variance of air gap depends on the characteristics of air gap discharge and, in case of commercial voltage, the degree of dependance is greeter than in case of direct current voltage.

  • PDF

Study on the measuring uncertainty of wide band PD measuring instrument (Wide band 측정기를 이용한 PD계측에서 측정신뢰도의 추정에 관한 연구)

  • Jeong, Jung-Il;Kim, Jong-Hyung;Shon, Hwa-Young;Kim, Kyu-Sub;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1896-1897
    • /
    • 2005
  • 보이드, 이물, 돌기 둥 고분자 절연체 내의 결함은 이곳에 전계가 가해질 때, 국부적 전계집중을 유발하며, 절연체 내의 미소 방전을 일으킨다. 이 때 발생한 미소 방전에 의해 보이드 표면의 고분자 물질은 기계적, 화학적 열화를 일으키며, 이에 따라 전기적 트리를 형성하게 된다. 이러한 트리는 결국 절연체의 절연파괴로 진전되므로, 고분자 물질을 절연물로 사용하는 전력기기의 경우에는 신뢰성에 큰 문제를 유발한다. 따라서, 이러한 방전(부분방전)이 일어날 때 생기는 전기적 신호를 검출하여, 절연물의 신회성을 평가하는 것은 매우 중요하다. 이러한 부분방전은 IEC둥 국제기술기준에 그 제한 값이 정하여져 있으며, 본 논문에서는 이러한 값을 수학적으로 평가하는 방법에 대해 연구하였다.

  • PDF

Treeing Phenomena of Epoxy-Layered Silicate Nanocomposites (Epoxy-Layered Silicate Nanocomposites Treeing 현상에 관한 연구)

  • Park, Jae-Jun;Cho, Dae-Ryng;Cho, Hog-Sok;Kim, Kyung-Tae;Hwang, Byung-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.371-372
    • /
    • 2008
  • 본 논문은 새롭게 초음파 분산기법을 이용하여 제조된 나노콤포지트 와 원형에폭시 수지에 대한 전기적 특성인 트리현상의 여러특성을 연구하였다. 나노필러인 Layered Silicate Particles가 에폭시수지 중에 Power Ultrasonic으로 분산된 나노콤포지트를 제조하였다. 충진된 혼합물에서 나노입자의 영향을 조사하기위해 열적, 구조적 특성을 연구하였고, 장시간 절연파괴 특성을 조사하기위해 침대평판 전극으로 원형에폭시수지와 나노콤포지트와 비교 측정하였다. 연구는 에폭시원형수지에 대한 인가전압레벌(교류 10, 15, 20kV)의 변화와 온도변화에 대한 (30,90,$130^{\circ}C$)의 트리특성을 연구하였다. 모든 전압레벨에서는 일정전압까지 1kV/s 로 승압 후 일정하게 인가되었고, 파괴에 이를 때까지 측정한 결과 10kV, 15Kv, 20KV의 경우 1042,75,488분후에 파괴에 이르렀다. 그러나 트리진행속도는 인가전압이 높을수록 빠르게 진행하였다. 온도 변화에 대한 트리특성으로서 15kV인가 후 파괴에 이르는 시간은 30,90,$130^{\circ}C$의 경우 75.3, 970, 226분으로 $90^{\circ}C$의 경우 절연성능이 가장 우수하였고, 트리진전속도는 $30^{\circ}C,130^{\circ}C,90^{\circ}C$ 순으로 나타났다. 이는 트리진전으로 파괴에 이르는 시간과 속도는 트리형태에 지배적으로 영향을 맡고 있음을 알 수 있었다. 또한 나노콤포지트 트리의 경우 15kV인가시 10902에 파괴에 이르렀고, 트리진전속도는 0.000729mm/min으로 원형에 비하여 53.36배의 트리진전시간이 느리고, 파괴시간은 145배 오래 견디는 절연내력을 측정할 수 있었다.

  • PDF

Influence of Combustion Flame on Breakdown Characteristics of Vertical-Model Power Lines (수직배열 모델 전력선의 절연파괴 특성에 미치는 화염의 영향)

  • Park, Kwang-Seo;Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.85-92
    • /
    • 2008
  • Occurring forest fire or burning bushes beneath overhead transmission lines have caused breakdown disturbances of the system in many countries. In this study, experiments for flashover characteristics in the simulated condition of vertical power lines were conducted so as to investigate the reduction in insulation strength caused by combustion flame. As the results of an experimental investigation, it is demonstrated that flame can reduce breakdown voltages of the model lines according to height(h) of flame. The breakdown voltages were decreased with decreasing the height(h) of flame it can be seen that the average reduction of flashover levels, in comparison with the no-flame case, are 46.2[%] for h=9[cm] and 62.5[%] for h=3[cm] when ac voltage is applied.

Weibull Plot of Electrical Breakdown Strength for Nano-and-Micro Mixture Composites (Nano-and-Micro Mixture Composites에대한 절연파괴 Weibull Plot 특성 연구)

  • Park, Jae-Jun;Lee, Chang-Hoon;Kim, Jung-Ho;Cho, Dae-Lyoung;Lee, Dae-Kyun;Lee, Sang-Hyup;Kim, Jae-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1378_1380
    • /
    • 2009
  • 절연파괴 강도에대한 특성분석을 위해 와이블 plot을 이용하였다. ENMMC에서 실란처리와 미처리특성에서 실란처리된 결과 형상파라미터가 상대적으로 높은 값을 나타내었다. 이는 절연파괴결과가 균질함을 분명하게 나타낸 결과이다. 또한 스케일파리미터에서도 처리된 결과가 상대적으로 높은 결과를 보이고 있다. 나노입자 충진함량에 대한 효과에서도 체적비로 6.2vol%가 24.87vol%보다 월등하게 높은 형상파리미터와 스케일 파리미터를 나타내었다. 현장에서는 B10의 수명이 누적확률(63.2%)보다 오히려 유효한 평가자료 라고 사료된다. 역시 실란처리 된 결과가 미처리된 것에 비하여 그리고 나노입자 충진함량이 적을수록 높은 결과를 나타내었다. 이로서 중전기기 산업절연재료로서 향후 전망을 크게 할 것으로 본다.

  • PDF

Degradation Diagnosis of Complex System Using Regression Analysis (희귀분석을 이용한 복합 시스템의 열화진단)

  • Kim, Seong-Hong;Song, Jae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.60-66
    • /
    • 2001
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

  • PDF

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2021
  • In this paper, we aimed to identify the insulation characteristics and reliability of Epoxy composites, which are widely used as insulation material for electrical & electronic components and electric appliance. To this end, it was necessary to predict variations of electric field due to the distribution of fillers that must be added by economic and mechanical factors. So, we verified the result using an electric field analysis Simulator. Furthermore, under the condtion of DC voltage application, an dielectirc breakdown test was performed according to ambient temperature changes and the distribution of fillers, and the changes were observed. Three types of specimens were manufactured by adding 0, 50 and 100[phr] filling to Epoxy resin. In all specimens, as temperature was increased, the strength of the dielectric strength was decreased. When comparing the simulation results with the actual dielectric breakdown test results, we was able to confirm the technical applicability required for Insulation design of electric appliance.