• Title/Summary/Keyword: 전기적 센서

Search Result 1,500, Processing Time 0.028 seconds

A Study on the Improvement of Reliability of Line Conversion Monitoring System using CCTV Camera (CCTV카메라를 활용한 선로전환감시시스템의 신뢰성 향상에 관한 연구)

  • Moon, Chae-young;Kim, Se-min;Ryoo, Kwang-ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.400-402
    • /
    • 2019
  • The electric point machine, which is used for the control of the turnout used to change the track of the train, is very important in the railway system. Various wired and wireless real-time monitoring systems are used to check the status of the point machine, but there is a possibility of malfunction due to sensor or network error. In this paper, a redundant monitoring system was designed that incorporates the point machine monitoring system and the CCTV camera control system to double check the operation of the point machine. In the point machine monitoring system, the operating state of the railway converter is monitored, alarmed and transmitted over the network. The CCTV camera control system, which received this information, was required to record the status of the turnout and the point machine in question and send it to the administrator. The manager of the railway line can check the conversion status of the railway through the monitoring screen for the railway line switcher first, and then confirm the switching status directly through the CCTV camera image, thereby improving the reliability of the point machine operation. It will also enable the safe and efficient operation of personnel for management. It is expected to contribute to preventing a derailment caused by a malfunction of the point machine.

  • PDF

Development of Synthetic Signal Generator and Simulator for Performance Evaluation in Multiple Sonobuoy System (다중 소노부이 체계의 신호합성기 및 성능검증용 시뮬레이터 개발)

  • Lee, Su Hyoung;Park, Sang Bae;Han, Sang-Gyu;Kown, Bum Soo
    • Journal of the Korea Society for Simulation
    • /
    • v.30 no.2
    • /
    • pp.11-22
    • /
    • 2021
  • Sonobuoy is widely used as a very important sensor in combat management system using P-3 patrol aircraft due to its advantages of rapid searching into wide exploration range. It is necessary to verify the performance of developed sonobuoy system using various maritime test data in order to be successfully applied in combat management system. But it is difficult to acquire various real maritime data because it needs much time and effort. Therefore we have developed in this paper a synthetic signal generator and a simulator that they can verify the performance of sonobuoy system and evaluate its operational effectiveness without conducting maritime test. We have synthesized target signals based on the characteristics of underwater sound sources, and then developed the synthesized signal generator which consider to sound propagation etc. like as underwater environment. And in the simulator development we use a HMI technique to enhance the convenience of operator, and design to verify the performance of sonobuoy system. The developed signal generator and simulator can be used as useful tools to evaluate the operational effectiveness such as optimal deployment of sonobuoy in combat management system using P-3 patrol aircraft.

Analysis on Optical and Water Quality Measurements for Red Tide Waters (적조 해수의 광학 및 수질변수 관측자료 분석)

  • Koh, Sooyoon;Baek, Seungil;Lim, Taehong;Jeon, Gi-Seong;Jeong, Yujin;Kim, Phillip;Lee, Min-young;Son, Moonho;Kim, Yejin;Kim, Wonkook
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1541-1555
    • /
    • 2022
  • Red tide has potential to harm marine ecology and aquaculture. Research on detecting red tide using various optical remote sensors has been conducted, but most of existing algorithms for detecting red tide has limitations, especially in shallow coastal waters with high levels of suspended sediment. For enhanced understanding of the optical behavior of red tide waters, analysis on remote sensing reflectance and water constituent is becoming increasingly important. This study analyzed the optical remote sensing data and water quality variables(Chl-a(Spec), SPM, aph, ad, Turbidity, Chl-a(HPLC), Dominant species) of red tide waters. The data were collected from ship-based campaigns. In addition to the research on detecting red tide, the remote sensing reflectance and extinction coefficients for mesodinium and cochlodinium species were also analyzed. Through the analysis, it was possible to estimate the red tide chlorophyll concentration based on a specific wavelength of the remote sensing reflectance. The study found that chlorophyll concentration and phytoplankton absorption coefficient were highly correlated(R2=0.9), and that the REdiff formula provided a more accurate estimate of red tide concentration than the B-G ratio.

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

Progress in Nanofiltration-Based Capacitive Deionization (나노여과 기반 용량성 탈이온화의 진전)

  • Jeong Hwan Shim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.87-95
    • /
    • 2024
  • Recent studies explore a wide array of desalination and water treatment methods, encompassing membrane processes such as reverse osmosis (RO), nanofiltration (NF), and electrodialysis (ED) to advanced capacitive deionization (CDI) and its membrane variant (MCDI). Comparative analyses reveal ED's cost-effectiveness in low-salinity scenarios, while hybrid systems (NF-MCDI, RO-NF-MCDI) show improved salt removal and energy efficiency. Novel ion separation methods (NF-CDI, NF-FCDI) offer enhanced efficacy and energy savings. These studies also highlight the efficiency of these methods in treating complex wastewater specific to various industries. Environmental impact assessments emphasize the need for sustainability in system selection. Additionally, the integration of microfabricated sensors into membranes allows real-time monitoring, advancing technology development. These studies underscore the variety and promise of emerging desalination and water treatment technologies. They provide valuable insights for enhancing efficiency, minimizing energy usage, tackling industry-specific issues, and innovating to surpass conventional method limitations. The future of sustainable water treatment appears bright, with continual advancements focused on improving efficiency, minimizing environmental impact, and ensuring adaptability across diverse applications.

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF

Monitoring of Concrete Deterioration Caused by Steel Corrosion using Electrochemical Impedance Spectroscopy(EIS) (EIS를 활용한 철근 부식에 따른 콘크리트 손상 모니터링)

  • Woo, Seong-Yeop;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.651-662
    • /
    • 2022
  • The electrochemical impedance spectroscopy(EIS) method was used to evaluate the concrete deterioration process related to chloride-induced steel corrosion with various corrosion levels(initiation, rust propagation and acceleration periods). The impressed current technique, with four total current levels of 0C, 13C, 65C and 130C, was used to accelerate steel corrosion in concrete cylinder samples with w/c ratio of 0.4, 0.5, and 0.6, immersed in a 0.5M NaCl solution. A series of EIS measurements was performed to monitor concrete deterioration during the accelerated corrosion test in this study. Some critical parameters of the equivalent circuit were obtained through the EIS analysis. It was observed that the charge transfer resistance(Rc) dropped sharply as the impressed current increased from 0C to 13C, indicating a value of approximately 10kΩcm2. However, the sensitivity of Rc significantly decreased when the impressed current was further increased from 13C to 130C after corrosion of steel had been initiated. Meanwhile, the double-layer capacitance value(Cdl) linearly increased from 50×10-6μF/cm2 to 250×10-6μF/cm2 as the impressed current in creased from 0C to 130C. The results in this study showed that monitoring Cdl is an effective measurement parameter for evaluating the progress of internal concrete damages(de-bonding between steel and concrete, micro-cracks, and surface-breaking cracks) induced by steel corrosion. The findings of this study provide a fundamental basis for developing an embedded sensor and signal interpretation method for monitoring concrete deterioration due to steel corrosion at various corrosion levels.

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

A Study on the Improvement of User Value through the Analysis of the Status of Smart Home Service in Korea Based on the Internet of Things (사물인터넷 기반 국내 스마트 홈서비스 현황 및 사용 후기 분석을 통한 사용자 가치 제고방안에 관한 연구)

  • Yoon, Seong-Jeong;Kim, Min-Yong
    • Management & Information Systems Review
    • /
    • v.36 no.5
    • /
    • pp.45-60
    • /
    • 2017
  • This study aims to elucidate the key improvements through the current state of customer support for smart home services based on the Internet of things and the evaluation of user's usage. Smart home services typically provide a wide range of value in terms of security, safety, manageability (electricity and water use), convenience, and remote management accessibility. In this study, we analyzed the current state of smart home service based on Internet of Samsung, SKT and LG U + companies in Korea. However, since LG U+ is the only company providing user reviews, there is a limit to generalization, but we are trying to figure out whether the customer value is conveyed properly or not, and in which part the customer support is focused to support the service. As a result of analyzing the results of the study, we found that the smart home service is commercialized and marketed in various forms. However, it is questionable whether the technological level and user satisfaction level are sufficiently satisfied. The results of this study are as follows. First, although each company provides usage guidance, they still ask many questions about joining products and using products. Second, there are many defects in the product itself, and it is found that the companies are not satisfied with the overall response. Third, the three companies are focusing on switches, outlets, sensors, and lamps. This is an individual intelligent product rather than an interlocking or linking level, and it can be seen that there are many parts that are not compatible with the concept of the original Internet of things. In conclusion, this study shows that there are still many areas to improve on the level of customer service provision of smart home service, in particular, the ease of use is low and the quality of products is not reliable. We would like to present the improvement of this in detail through this study and reflect the companies that provide it and the service providers.

Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area - (큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 -)

  • Yoon Yong Cheol;Suh Won Myung;Yu Chan
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.217-225
    • /
    • 2004
  • This study was performed to provide the basic knowledge about the mushroom cultivation facilities. Classified current status of cultivation facilities in Gyeongnam province was investigated by questionnaire. The structure of Pleurotus eryngii cultivation facilities can be classified into the simple and permanent frame type. The simple frame structures were mostly single-span type, on the other hand, the permanent frame structures were more multi-span than simple structures. And the scale of cultivation facilities was very different regardless of structural type. But as a whole, the length, width and ridge height were prevailing approximately 20.0 m, $6.6\~7.0m$ and $4.6\~5.0m$ range, respectively. The floor area was about $132\~160\;m^2$, and floor was built with concrete to protect mushrooms from various harmful infection. The roof slope of the simple and permanent type showed about $41.5^{\circ}\;and\;18.6\~28.6^{\circ}$, respectively. The width and layer number of growing bed for mushroom cultivation were around $1.2\~1.6m$, 4 layers in common, respectively. Most of year round cultivation facilities were equipped with cooler, heater, humidifier, and ventilating fan. Hot water boiler was the most commonly used heating system, the next was electric heater and then steam boiler. The industrial air conditioner has been widely used for cooling. And humidity was controlled mostly by ultra-wave or centrifuging humidifier. But some farmers has been using nozzle system for auxiliary purpose. More then $90\%$ of the mushroom house had the independent environment control system. The inside temperature was usually controlled by sensor, but humidity and $CO_2$ concentration was controlled by timer for each growing stage. The capacity of medium bottle was generally 850 cc and 1100cc, some farms used 800 cc, 950 co and 1,250 cc. Most of mushroom producted has been usually shipped to both circulating company and joint market.