• Title/Summary/Keyword: 전기자극 시스템

Search Result 75, Processing Time 0.025 seconds

Development of EMG-Triggered FES System and Optimal Electrode Location for Chronic Hemiplegic Patients (편마비 환자를 위한 근전도 유발 기능적 전기자극기의 개발과 이상적인 전극부착 위치)

  • 박병림;안상호;정호춘;진달복;김성곤;이상세;김영기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.151-156
    • /
    • 2004
  • The purpose of this study was to develop EMG triggered FES system for restoration of upper extremity function in chronic hemiplegic patients and to identify the optimal location of electrode application for the EMG triggered FES system which produces effective muscle contraction and detects EMG activity for extension in the wrist and finger joints. The stimulus system was composed of EMG measuring component, constant current component and the program for muscle contraction by EMG triggered FES and passive FES. Parameter of electrical stimulation was 35 ㎐ in frequency, 150 ${\mu}\textrm{s}$ in pulse width and symmetric bi-phasic wave. In 15 hemiplegic patients, EMG triggered FES was applied to the proximal half of forearm which was divided into 12 areas. The most sensitive area for measuring EMG activities during extension of the wrist and fingers was area 4, 5 and the optimal location of electrical stimulation for producing extension of the wrist and fingers was area 4, 5, 7, 8. These results suggest that the area 4 and 5 was considered as the most optimal location of electrode application for measuring EMG activities as well as producing extension of the wrist and fingers by EMG triggered FES system.

Residual Neuromuscular Sensing Platform Development using Sensor of Nerve Stimulation Response Measurement during Anesthesia (신경자극반응 측정 센서를 이용한 마취 시 잔여근이완 감지 플랫폼 구현)

  • Shin, Hyo-Seob;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.459-462
    • /
    • 2010
  • Response to nerve stimulation platform for implementing measures to detect finger movement has been functioning as an important factor. This stimulated finger on the nerve and muscle responses would vary. In other words, the finger movement of the muscle response to nerve stimulation and sensing Actuator for the H/W development is needed. In addition, a low power embedded CPU based on the top was used. H/W configuration portion of the isolation power, constant current control, High impedance INA, amplifier parts, and the stimulus mode and the Micro-control the status of current, AD converter Low Data obtained through the processing system is implemented.

  • PDF

Example Development of Medical Equipment Applying Power Electronics Technique (전력전자 기술을 응용한 의료장비 개발 사례)

  • 고종선;이태훈;김영일;김규겸;박병림
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.524-530
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement and skeletal muscle contract. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for- stimulation with horizontal, vortical and 3D patterns. The Off-vortical axis rotator is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

전기공학 분야에서의 컴퓨터 응용

  • 이수길;한기만;이준웅
    • 전기의세계
    • /
    • v.43 no.9
    • /
    • pp.31-38
    • /
    • 1994
  • 저자는 이 글을 통하여 현재의 컴퓨터 기술 동향에 대해서 간략하게 살펴보고 미래의 전력시스템에서 사용되어지리라고 사료되는 컴퓨터 응용 프로그램에 대해서 고찰해보았다. 미래의 전기공학계에서 쓰여질 이러한 프로그램들의 구체적이고 완전한 고찰은 이루어지기 힘들겠지만 미래 지향적인 사고를 자극하여 컴퓨터의 진보적인 발전으로부터 몇가지 잇점들을 얻을 수 있도록 전력케이블의 상태분석을 포함한 전력 시스템 공학 분야들의 현황과 미래의 발전상에 대해서 다루었다.

  • PDF

A Study on Neuroactive Response Measurement Platform using Mechano Sensor (Mechano sensor를 이용한 신경자극반응 측정 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.198-201
    • /
    • 2012
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls. The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation, Train-of-four, and Double Burst Stimulation in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

Suggestion on ubiquitous healthcare device on the basis of ECoG and Optogenetics (광유전학과 피질전도 측정 장치 기반 유비쿼터스 헬스케어 장치 제안)

  • Jeong, Jae-won
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.153-155
    • /
    • 2017
  • 최근 건강관리 및 질병관리 등에 대한 관심이 증가하면서 유비쿼터스 헬스케어 서비스와 관련 기기에 대한 개발이 활발히 진행 중이다. 또한, 관련 기기가 단순히 건강진단 및 질병진단과 더불어서 치료까지 하나의 기기에서 이루어지는 테라그노시스 방향으로 개발되고 있다. 또한 치료를 위해 광유전학 기술을 이용하여 광반응성 단백질인 ChR2로 뇌세포의 자극을 조절할 수 있다. 뇌세포의 자극을 조절함으로써 뇌 질환의 발현 시 유용하게 대처할 수 있다. 본 논문에서 뇌의 전기적 신호를 획득하는 기기와 연동되는 IoT 시스템을 통해서 유비쿼터스 헬스케어에 대한 방법론에 대해서 서술한다. 특히, 뇌의 전기적 신호를 획득하는 장치를 통한 뇌, 신경 질환인 뇌전증에 대한 진단과 치료의 유무를 판단하는 유비쿼터스 헬스케어 시스템에 대해서 서술한다. 이처럼 웨어러블 뇌파 신호 측정 장치와 연동되는 IoT 시스템을 통해 뇌파 신호를 지속적으로 모니터함으로써 사용자의 뇌전증의 발현 시 진단 및 치료, 긴급연락 서비스를 통해 사용자의 돌발 사태에 대해서 대처할 수 있는 방법론을 제시한다.

  • PDF

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF