• Title/Summary/Keyword: 전관 방송

Search Result 14, Processing Time 0.022 seconds

Power Line Communication Based Public Address System (전력선 통신 기반 전관방송 시스템)

  • Kim, Seok;Kim, Dae-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1035-1042
    • /
    • 2017
  • In this paper, we implement a public address system using power line communication in order to operate, extend, and expand the complicated public address devices and cables easily. Power line communication based public address system implemented consists of a public address control board and public address speaker boards which are suitable to digital streaming modulation. It can be noticed that we met satisfied results from performance measurement such as maximum audio output, audio channel response time, audio output SNR, and audio output THD+N.

A Study on the Problems and Improvement of the Interface of Indoor Alarm Broadcasting System (옥내경보방송시스템 연계의 문제점 및 개선방안 연구)

  • Lee, Seung-Hyung;Ahn, Byung-Dug;Lee, Won-Seok;Min, Se-Hong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.285-287
    • /
    • 2018
  • 최근 우리나라에서도 지진이 발생하는 등 각종 재난의 발생 빈도가 증가하고 있어 이에 대비하는 사회적 필요성이 대두되고 있다. 특히, 재난발생 시 일반 대중들에 전달되는 경보와 방송에 대한 관심이 높아지고 있다. 국내 재난경보방송시스템은 오랜 역사를 거쳐 정부와 지자체가 관심을 가지고 구축해 왔으며, 인구가 밀집되어 있는 장소나 여름철 집중호우가 예상되는 유원지 등에 집중적으로 설치되어 있다. 옥외를 중심으로 경보방송을 서비스하고 있었으나 건물 내부에는 경보나 방송이 전달되지 못하여 재난발생 시 대규모 피해가 예측되므로 옥내경보방송 서비스의 필요성이 중요하게 인식되었고 최근에는 지자체 별로 활발하게 시스템 설치가 진행되고 있다. 옥내경보방송은 구내방송시설인 전관방송시스템과 연계되어 서비스하는 방향으로 진행되고 있으며 본 저자도 이에 동의하는 바이다. 그러나 전관방송시스템은 오랜 동안 이와 같은 필요성이 없는 상태에서 구축되어 왔고 제조사 별로 외부장비의 연계 방식에 대하나 규격이 다르게 발전해 왔다. 따라서 옥내경보방송장치와 전관방송시스템을 연계하기 위해서는 장비의 제어와, 오디오 인터페이스(interface)가 필수적 요소이므로 이를 반드시 연계하여야 한다. 본 논문에서는 옥내경보방송장치와 전관방송시스템들의 인터페이스를 위해 문제점들을 분석하고 이들의 개선방안에 대해 연구한다. 또한 연계 규격의 표준화에 대한 필요성을 강조하여 각 제조사들이 연계 규격을 준수하고 보다 많은 국민들이 재난경보방송 서비스를 누릴 수 있도록 제언한다.

  • PDF

Performance comparison of PA(public address) power amplifier with different output level (출력 레벨에 따른 전관방송용 파워앰프의 성능 비교)

  • Kim, Hyeryoung;Im, ChaeHun;Kwon, DongHyun;Jeong, Inmyoung
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.151-154
    • /
    • 2013
  • 본 논문에서는 전관방송 시스템에 사용되는 전관방송용 파워앰프에 대해 TTA에서 개발한 시험규격을 설명하고, 주요 시험항목에 대해 출력 레벨에 따라 어떠한 특성이 나타나는지 시험 결과를 분석하였다. 시험을 위해 현재 상용으로 판매되는 정격출력이 260 W, 360 W, 480 W, 600 W 인 앰프를 사용하였고, 각각의 앰프에 대해 정격출력, 1/2 정격, 1/4 정격, 1/8 정격, 10W, 1W 일 때 주파수 응답, 신호대잡음비, THD+N 비를 측정하여 비교하였다. 향후 본 논문의 시험 데이타가 전관방송용 앰프의 성능을 가늠할 때 중요 지표가 될 것으로 기대한다.

  • PDF

Firmware and UI for Power Line Communication Based Public Address System (전력선 통신 기반 전관 방송시스템의 펌웨어와 UI)

  • Kim, Seok;Kim, Dae-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.127-136
    • /
    • 2019
  • The public address system should be easily operated and managed by the users, and guaranteed to serve stable working in an emergency and a crisis. In this paper, In this paper, to provide power line communication based public address system users with convenience and efficiency, we implement a firmware to control communication between a PLC(: Power Line Communication) controller of the public address system and UI(: User Interface) and between a PLC controller of the public address system and PLC speakers, and develop a UI software.

Development of an Intelligent Digital Public Address System with Sensing and Unicasting (센싱과 개별 방송이 가능한 지능형 디지털 전관 방송 시스템 개발)

  • Kim, Jung-Sook;Jung, Jun-Ho;Chung, Jang-Young;Song, Chee-Won
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.193-194
    • /
    • 2012
  • 현재 자연재해 증가와 응급 상황 발생이 빈번해짐에 따라 정부에서 소방법을 강화하였다. 따라서 대부분의 빌딩에서는 응급 상황이나 자연 재해 발생이 발생할 경우, 신속한 대피를 위한 안내 방송을 할 수 있는 전관 방송 시스템 설비를 반드시 갖추어야 한다. 이에 본 연구에서는 빌딩에 설비되어 있는 각종 다양한 센서들로부터 센싱된 정보를 네트워크를 통해 전달 받아 이들을 실시간으로 분석하여 빌딩 상황에 맞는 안내 방송과 응급 상황시 대피를 위한 안내 방송뿐만 아니라 빌딩에 있는 각 호수별로 ID를 부여하고, 이를 통해 방송이 필요한 장소에만 개별 방송을 할 수 있는 디지털 전관 방송 시스템을 개발하였다.

  • PDF

Development of Integrated Public Address System for Intelligent Building (지능형 빌딩을 위한 디지털 통합 전관 방송 시스템 개발)

  • Kim, Jung-Sook;Song, Chee-Won
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.2
    • /
    • pp.212-217
    • /
    • 2011
  • In this paper, we developed an intelligent minimized integrated digital public address which can provide context awareness of various events occurring in future intelligent buildings. It is able to recognize both voices and sounds, such as a fire bell and a disaster bell, which signal to escape in emergence situations and it can sense information which is sent from various sensors, for example, the inner temperature, humidity, and environment status in an intelligent building. Also, the intelligent digital integrated public address can broadcast information to individual places, according to context awareness that is from sensing information, by using network with an ID. And we are developing a minimized integrated digital public address system that has facilities such as external input, Mic., CD, MP3 and Radio. Developing an integrated digital public address system with operational MICOM will make it possible to control the facilities of digital devices centrally. The operational MICOM is composed of 3 layers which are a control layer, a processing layer and a user interface layer.

Development of Integrated Mixer Controller for Digital Public Address (디지털전관방송을 위한 통합믹서컨트롤러 개발)

  • Cho, Juphil;Kim, Kwan-Woong;Kim, Daeik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Nowadays, based on the advancement of IT techniques, innovative products combining IT techniques to PA system are developing. In this paper, we presented the hybrid mixer controller for digital PA system. We develop the integrated mixer controller which includes the digital mixer composing an existing digital PA system and function of digital integrated controller. Developed integrated mixer controller consists of multichannel mixer function with 16 audio input channels, 8 output channels. And, it has an equalizer for processing digital audio signal, matrix and limiter. Also, the developed controller has some features such as internet connection for controlling of overall PA system and remote monitoring of mixer process condition.

Redundancy operation method for a distributed public address system (분산형 전관방송 시스템의 이중화 운영 방법)

  • Ryu, Taeha;Kim, Seungcheon
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.47-53
    • /
    • 2020
  • In the case of a failure due to equipment deterioration in the public address system or a worker's mistake during construction, broadcasting becomes impossible. In this situation, we have designed a more advanced management broadcast system that can broadcast. The broadcasting service is operated using main broadcasting device, and local broadcasting device operates separately only in the local area. If the main broadcasting device becomes inoperable, the procedure for transferring the control activates the device with the local broadcasting devices based on data backed up by the main controller. This paper proposes an improved method of the conventional emergency broadcasting device duplication method. The existing method could not use the standby equipment in the normal state, but in the proposed method, the standby equipment can be used as local broadcasting equipment in usually. This method enables stable system operation while minimizing resource waste due to redundant configuration of expensive devices.

Development of an Operational MICOM for efficient Central Control of Public Address System (통합 전관 방송 시스템의 효율적인 중앙 집중 제어를 위한 운용 MICOM 개발)

  • Kim, Jung-Sook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.325-329
    • /
    • 2011
  • We are developing a minimized integrated public address system that has facilities such as external input, Mic., CD, MP3 and Radio. In this paper, developing an integrated public address system with operational MICOM will make it possible to control the facilities of digital devices centrally. The operational MICOM is composed of 3 layers which are a control layer, a processing layer and a user interface layer. The control layer controls digital devices in the integrated public address and the processing layer is for processing voice data editing, controlling signals of devices and providing status information of the device. The user interface layer displays the status of control devices and the data processing of a user. A remote control is used for the central control.

The development of Intuitive User Interface and Control Software for Audio Mixer in Digital PA System (디지털전관방송시스템을 위한 오디오믹서의 직관적인 사용자 인터페이스 및 제어 소프트웨어 개발)

  • Kim, Kwan Woong;Cho, Juphil
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.3
    • /
    • pp.307-312
    • /
    • 2018
  • In this paper, we can confirm the result of intuitive interface software implementation for operating a digital PA(Public Address) controller and the performance of audio mixer control part. Developed user interface software provides the maintaining management and control function of digital hybrid mixer. This SW loaded in the integrated control server controls an sound status of the audio mixer TAD-168M and checks the device status for Public Address integrated system. Also, this SW enables the integrated control and the continuous upgrade. Developed SW is connected to TAD-168M with Ethernet and linked to PC Lan port and the 4-port switch, located in the backside of TAD-168M, by LAN cable for communicating with operating PC. Integrated control including system management, audio control and uplink broadcasting control for broadcasting system will be made available with this novel developed system.