• Title/Summary/Keyword: 적용범위

Search Result 7,178, Processing Time 0.037 seconds

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Experiment for Various Soils on Economic Duty of Water in Paddy Fields (각종토성별 경제적용수량 결정시험연구)

  • Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1561-1579
    • /
    • 1969
  • In Korea, the duty of water in paddy fields was measured at the Agricultural Experimental Station in Suwon about 60 years ago. After that time some testing has been made in several places, but the key points in its experiment were the water depth of evapo-transpiration. Improved breeds, progress in cultivation and management techniques as well as development of measuring apparatus in recent years have necessitated the review of the duty of water in paddy fields. The necessity of reviewing the conventional methods has become even more important, as no source of information has been made available through survey of water utilization on a soil use basis which requires data on peculiar features of the water depth of evapo-transpiration. For example, the duty of water in paddy field is largely affected by the water depth of evapo-transpiration in connection with the wetted paddy field, whereas in connection with the normal paddy fields without this characteristic the vertical percolation become the predominant factor in measuring the decreasing depth of water. Therefore, it becomes important. that not only the water depth of evapotranspiration but also the vertical percolation process should also be observed in order to arrive at a realistic conclusion. As the vertical percolation has aclose relationship to the height of the underground water, the change of the latter can be measured. As the conclusion of this experiment, the following subjects are indicated. 1. In order to determine the economic duty of water in paddy fields on a basis of varying soil features, the varying soil features in the benifited area should be investigated thoroughly. The water depths of evapo-transpiration(ET) ratio to evaporation in the evaporator(V) on a basis of the varying soil features are as follows: clay loam ET/V = 1.11, loam ET/V = 1.64, sandy loam ET.V = 1.63 2. The decreasing depth of water consists of the water depth of evapotranspiration, the vertical per colation and the percolation of foot path. Among these three, the percolation of foot path can be utilized again. 3. As the result of this experiment, it shows the decreasing depth of water as follows. clay loam 9.3 mm/day, loam 13.5mm/daty, sandy loam 15.3mm/day 4. On a basis of the varying soil features and the height of the underground water, the vertical percolation varies. 5. The change of the vertical percolation on a basis of the varying soil features shows as follows: clay loam $1{\sim}2$ mm/day, loam $2{\sim}3$mm/day, sandy loam $3{\sim}4$mm/day 6. The level of the underground water changes sensibly by priority of clay loam, loam, sandy loam. When it rains, the level of the underground water rises fast and falls down slowly. 7. The level of the underground water changes within the scope of 25cm 8. The transpiration ratio is given in table 8 and their value are as follows: clay loam 168.8, loam 255.6, sandy loam 272.5

  • PDF

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

A Study on Modernization of International Conventions Relating to Aviation Security and Implementation of National Legislation (항공보안 관련 국제협약의 현대화와 국내입법의 이행 연구)

  • Lee, Kang-Bin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.201-248
    • /
    • 2015
  • In Korea the number of unlawful interference act on board aircrafts has been increased continuously according to the growth of aviation demand, and there were 55 incidents in 2000, followed by 354 incidents in 2014, and an average of 211 incidents a year over the past five years. In 1963, a number of states adopted the Convention on Offences and Certain Other Acts Committed on Board Aircraft (the Tokyo Convention 1963) as the first worldwide international legal instrument on aviation security. The Tokyo Convention took effect in 1969 and, shortly afterward, in 1970 the Convention for the Suppression of Unlawful Seizure of Aircraft(the Hague Convention 1970) was adopted, and the Convention for the Suppression of Unlawful Acts Against the Safety of Civil Aviation(the Montreal Convention 1971) was adopted in 1971. After 9/11 incidents in 2001, to amend and supplement the Montreal Convention 1971, the Convention on the Suppression of Unlawful Acts Relating to International Civil Aviation(the Beijing Convention 2010) was adopted in 2010, and to supplement the Hague Convention 1970, the Protocol Supplementary to the Convention for the Suppression of Unlawful Seizure of Aircraft(the Beijing Protocol 2010) was adopted in 2010. Since then, in response to increased cases of unruly behavior on board aircrafts which escalated in both severity and frequency,, the Montreal Protocol which is seen as an amendment to the Convention on Offences and Certain Other Acts Committed on Board Aircraft(the Tokyo Convention 1963) was adopted in 2014. Korea ratified the Tokyo Convention 1963, the Hague Convention 1970, the Montreal Convention 1971, the Montreal Supplementary Protocol 1988, and the Convention on the Marking of Plastic Explosive 1991 which have proven to be effective. Under the Tokyo Convention ratified in 1970, Korea further enacted the Aircraft Navigation Safety Act in 1974, as well as the Aviation Safety and Security Act that replaced the Aircraft Navigation Safety Act in August 2002. Meanwhile, the title of the Aviation Safety and Security Act was changed to the Aviation Security Act in April 2014. The Aviation Security Act is essentially an implementing legislation of the Tokyo Convention and Hague Convention. Also the language of the Aviation Security Act is generally broader than the unruly and disruptive behavior in Sections 1-3 of the model legislation in ICAO Circular 288. The Aviation Security Act has reflected the considerable parts of the implementation of national legislation under the Beijing Convention and Beijing Protocol 2010, and the Montreal Protocol 2014 that are the modernized international conventions relating to aviation security. However, in future, when these international conventions would come into effect and Korea would ratify them, the national legislation that should be amended or provided newly in the Aviation Security Act are as followings : The jurisdiction, the definition of 'in flight', the immunity from the actions against the aircraft commander, etc., the compulsory delivery of the offender by the aircraft commander, etc., the strengthening of penalty on the person breaking the law, the enlargement of application to the accomplice, and the observance of international convention. Among them, particularly the Korean legislation is silent on the scope of the jurisdiction. Therefore, in order for jurisdiction to be extended to the extra-territorial cases of unruly and disruptive offences, it is desirable that either the Aviation Security Act or the general Crime Codes should be revised. In conclusion, in order to meet the intelligent and diverse aviation threats, the Korean government should review closely the contents of international conventions relating to aviation security and the current ratification status of international conventions by each state, and make effort to improve the legislation relating to aviation security and the aviation security system for the ratification of international conventions and the implementation of national legislation under international conventions.

Evaluating Reverse Logistics Networks with Centralized Centers : Hybrid Genetic Algorithm Approach (집중형센터를 가진 역물류네트워크 평가 : 혼합형 유전알고리즘 접근법)

  • Yun, YoungSu
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.4
    • /
    • pp.55-79
    • /
    • 2013
  • In this paper, we propose a hybrid genetic algorithm (HGA) approach to effectively solve the reverse logistics network with centralized centers (RLNCC). For the proposed HGA approach, genetic algorithm (GA) is used as a main algorithm. For implementing GA, a new bit-string representation scheme using 0 and 1 values is suggested, which can easily make initial population of GA. As genetic operators, the elitist strategy in enlarged sampling space developed by Gen and Chang (1997), a new two-point crossover operator, and a new random mutation operator are used for selection, crossover and mutation, respectively. For hybrid concept of GA, an iterative hill climbing method (IHCM) developed by Michalewicz (1994) is inserted into HGA search loop. The IHCM is one of local search techniques and precisely explores the space converged by GA search. The RLNCC is composed of collection centers, remanufacturing centers, redistribution centers, and secondary markets in reverse logistics networks. Of the centers and secondary markets, only one collection center, remanufacturing center, redistribution center, and secondary market should be opened in reverse logistics networks. Some assumptions are considered for effectively implementing the RLNCC The RLNCC is represented by a mixed integer programming (MIP) model using indexes, parameters and decision variables. The objective function of the MIP model is to minimize the total cost which is consisted of transportation cost, fixed cost, and handling cost. The transportation cost is obtained by transporting the returned products between each centers and secondary markets. The fixed cost is calculated by opening or closing decision at each center and secondary markets. That is, if there are three collection centers (the opening costs of collection center 1 2, and 3 are 10.5, 12.1, 8.9, respectively), and the collection center 1 is opened and the remainders are all closed, then the fixed cost is 10.5. The handling cost means the cost of treating the products returned from customers at each center and secondary markets which are opened at each RLNCC stage. The RLNCC is solved by the proposed HGA approach. In numerical experiment, the proposed HGA and a conventional competing approach is compared with each other using various measures of performance. For the conventional competing approach, the GA approach by Yun (2013) is used. The GA approach has not any local search technique such as the IHCM proposed the HGA approach. As measures of performance, CPU time, optimal solution, and optimal setting are used. Two types of the RLNCC with different numbers of customers, collection centers, remanufacturing centers, redistribution centers and secondary markets are presented for comparing the performances of the HGA and GA approaches. The MIP models using the two types of the RLNCC are programmed by Visual Basic Version 6.0, and the computer implementing environment is the IBM compatible PC with 3.06Ghz CPU speed and 1GB RAM on Windows XP. The parameters used in the HGA and GA approaches are that the total number of generations is 10,000, population size 20, crossover rate 0.5, mutation rate 0.1, and the search range for the IHCM is 2.0. Total 20 iterations are made for eliminating the randomness of the searches of the HGA and GA approaches. With performance comparisons, network representations by opening/closing decision, and convergence processes using two types of the RLNCCs, the experimental result shows that the HGA has significantly better performance in terms of the optimal solution than the GA, though the GA is slightly quicker than the HGA in terms of the CPU time. Finally, it has been proved that the proposed HGA approach is more efficient than conventional GA approach in two types of the RLNCC since the former has a GA search process as well as a local search process for additional search scheme, while the latter has a GA search process alone. For a future study, much more large-sized RLNCCs will be tested for robustness of our approach.

Clinical and radiographic evaluation of $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface and external connection (SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 대한 임상적, 방사선학적 평가)

  • An, Hee-Suk;Moon, Hong-Suk;Shim, Jun-Sung;Cho, Kyu-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.125-136
    • /
    • 2008
  • Statement of problem: Since the concept of osseointegration in dental implants was introduced by $Br{{\aa}}nemark$ et al, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Neoplan^{(R)}$ implant, which features a sandblasted and acid-etched surface and external connection. Material and methods: 96 $Neoplan^{(R)}$ implants placed in 25 patients in Yonsei University Hospital were examined to determine the effect of the factors on marginal bone loss, through clinical and radiographic results during 18 to 57 month period. Results: 1. Out of a total of 96 implants placed in 25 patients, two fixtures were lost, resulting in 97.9% of cumulative survival rate. 2. Throughout the study period, the survival rates were 96.8% in the maxilla and 98.5% in the mandible. The survival rates were 97.6% in the posterior regions and 100% in the anterior regions. 3. The mean bone loss for the first year after prosthesis placement and the mean annual bone loss after the first year for men were significantly higher than that of women (P<0.05). 4. The group of partial edentulism with no posterior teeth distal to the implant prosthesis showed significantly more bone loss compared to the group of partial edentulism with presence of posterior teeth distal to the implant prosthesis in terms of mean bone loss for the first year and after the first year (P<0.05). 5. The mean annual bone loss after the first year was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. No significant difference in marginal bone loss was found in the following factors: jaws, type of prostheses, type of opposing dentition, and submerged /non-submerged implants (P<0.05). Conclusion: On the basis of these results, the factors influencing marginal bone loss were gender, type of edentulism, and location in the arch, while the factors such as arch, type of prostheses, type of opposing dentition, submerged / non- submerged implants had no significant effect on bone loss. In the present study, the cumulative survival rate of the $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface was 97.9% up to a maximum 57-month period. Further long-term investigations for this type of implant system and evaluation of other various domestic implant systems are needed in future studies.

A Study on Aviation Safety and Third Country Operator of EU Regulation in light of the Convention on international Civil Aviation (시카고협약체계에서의 EU의 항공법규체계 연구 - TCO 규정을 중심으로 -)

  • Lee, Koo-Hee
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.29 no.1
    • /
    • pp.67-95
    • /
    • 2014
  • Some Contracting States of the Chicago Convention issue FAOC(Foreign Air Operator Certificate) and conduct various safety assessments for the safety of the foreign operators which operate to their state. These FAOC and safety audits on the foreign operators are being expanded to other parts of the world. While this trend is the strengthening measure of aviation safety resulting in the reduction of aircraft accident. FAOC also burdens the other contracting States to the Chicago Convention due to additional requirements and late permission. EASA(European Aviation Safety Agency) is a body governed by European Basic Regulation. EASA was set up in 2003 and conduct specific regulatory and executive tasks in the field of civil aviation safety and environmental protection. EASA's mission is to promote the highest common standards of safety and environmental protection in civil aviation. The task of the EASA has been expanded from airworthiness to air operations and currently includes the rulemaking and standardization of airworthiness, air crew, air operations, TCO, ATM/ANS safety oversight, aerodromes, etc. According to Implementing Rule, Commission Regulation(EU) No 452/2014, EASA has the mandate to issue safety authorizations to commercial air carriers from outside the EU as from 26 May 2014. Third country operators (TCO) flying to any of the 28 EU Member States and/or to 4 EFTA States (Iceland, Norway, Liechtenstein, Switzerland) must apply to EASA for a so called TCO authorization. EASA will only take over the safety-related part of foreign operator assessment. Operating permits will continue to be issued by the national authorities. A 30-month transition period ensures smooth implementation without interrupting international air operations of foreign air carriers to the EU/EASA. Operators who are currently flying to Europe can continue to do so, but must submit an application for a TCO authorization before 26 November 2014. After the transition period, which lasts until 26 November 2016, a valid TCO authorization will be a mandatory prerequisite, in the absence of which an operating permit cannot be issued by a Member State. The European TCO authorization regime does not differentiate between scheduled and non-scheduled commercial air transport operations in principle. All TCO with commercial air transport need to apply for a TCO authorization. Operators with a potential need of operating to the EU at some time in the near future are advised to apply for a TCO authorization in due course, even when the date of operations is unknown. For all the issue mentioned above, I have studied the function of EASA and EU Regulation including TCO Implementing Rule newly introduced, and suggested some proposals. I hope that this paper is 1) to help preparation of TCO authorization, 2) to help understanding about the international issue, 3) to help the improvement of korean aviation regulations and government organizations, 4) to help compliance with international standards and to contribute to the promotion of aviation safety, in addition.

Different Uptake of Tc-99m ECD and Tc-99m HMPAO in the Normal Brains: Analysis by Statistical Parametric Mapping (정상 뇌 혈류 영상에서 방사성의약품에 따라 혈류 분포에 차이가 있는가: 통계적 파라미터 지도를 사용한 분석)

  • Kim, Euy-Neyng;Jung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.244-254
    • /
    • 2002
  • Purpose: This study investigated the differences between technetium-99m ethyl cysteinate dimer (Tc-99m ECD) and technetium-99m hexamethylpropylene amine oxime (Tc-99m HMPAO) uptake in the normal brain by means of statistical parametric mapping (SPM) analysis. Materials and Methods: We retrospectively analyzed age and sex matched 53 cases of normal brain SPECT. Thirty-two cases were obtained with Tc-99m ECD and 21 cases with Tc-99m HMPAO. There were no abnormal findings on brain MRIs. All of the SPECT images were spatially transformed to standard space, smoothed and globally normalized. The differences between the Tc-99m ECD and Tc-99m HMPAO SPECT images were statistically analyzed using statistical parametric mapping (SPM'99) software. The differences bgetween the two groups were considered significant ant a threshold of corrected P values less than 0.05. Results: SPM analysis revealed significantly different uptakes of Tc-99m ECD and Tc-99m HMPAO in the normal brains. On the Tc-99m ECD SPECT images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the basal ganglia and thalamus, and in the superior region of the cerebellum. On the Tc-99m HMPAO SPECT images, relatively higher uptakes was observed in subcortical areas of the frontal region, temporal lobe, and posterior portion of inferior cerebellum. Conclusion: Uptake of Tc-99m ECD and Tc-99m HMPO in the normallooking brain was significantly different on SPM analysis. The selective use of Tc-99m ECD of Tc-99m HMPAO in brain SPECT imaging appears especially valuable for the interpretation of cerebral perfusion. Further investigation is necessary to determine which tracer is more accurate for diagnosing different clinical conditions.

Developing the Process and Characteristics of Preservation of Area-Based Heritage Sites in Japan (일본 면형 유산 보존제도의 확산과정과 특성)

  • Sung, Wonseok;Kang, Dongjin
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.4
    • /
    • pp.32-59
    • /
    • 2020
  • South Korea's area-based heritage preservation system originates from the "Preservation of Traditional Buildings Act" enacted in 1984. However, this system was abolished in 1996. As there was a need for protection of ancient cities in the 1960s, Japan enacted the Historic City Preservation Act in 1966, and 'Preservation Areas for Historic Landscapes' and 'Special Preservation Districts for Historic Landscapes' were introduced. For the preservation of area-based heritage sites, the 'Important Preservation Districts for Groups of Traditional Buildings' system introduced as part of the revision of the Cultural Heritage Protection Act in 1975 was the beginning. Then, in the early-2000s, discussions on the preservation of area-based heritage sites began in earnest, and the 'Important Cultural Landscape' system was introduced for protection of the space and context between heritage sites. Also, '33 Groups of Modernization Industry Heritage Sites' were designated in 2007, covering various material and immaterial resources related to the modernization of Japan, and '100 Beautiful Historic Landscapes of Japan' were selected for protection of local landscapes with historic value in the same year. In 2015, the "Japanese Heritage" system was established for the integrated preservation and management of tangible and intangible heritage aspects located in specific areas; in 2016, the "Japanese Agricultural Heritage" system was established for the succession and fostering of the disappearing agriculture and fishery industries; and in 2017, "the 20th Century Heritage," was established, representing evidence of modern and contemporary Japanese technologies in the 20th century. As a result, presently (in September 2020), 30 'Historic Landscape Preservation Areas', 60 'Historic Landscape Special Districts,' 120 'Important Preservation Districts for Groups of Traditional Buildings," 65 'Important Cultural Landscapes,' 66 'Groups of Modernization Industry Heritage Sites,' 264 "100 Beautiful Historic Landscapes of Japan,' 104 'Japanese Heritage Sites,' and 15 'Japanese Agricultural Heritage Sites' have been designated. According to this perception of situations, the research process for this study with its basic purpose of extracting the general characteristics of Japan's area-based heritage preservation system, has sequentially spread since 1976 as follows. First, this study investigates Japan's area-based heritage site preservation system and sets the scope of research through discussions of literature and preceding studies. Second, this study investigates the process of the spread of the area-based heritage site preservation system and analyzes the relationship between the systems according to their development, in order to draw upon their characteristics. Third, to concretize content related to relationships and characteristics, this study involves in-depth analysis of three representative examples and sums them up to identify the characteristics of Japan's area-based heritage system. A noticeable characteristic of Japan's area-based heritage site preservation system drawn from this is that new heritage sites are born each year. Consequently, an overlapping phenomenon takes place between heritage sites, and such phenomena occur alongside revitalization of related industries, traditional industry, and cultural tourism and the improvement of localities as well as the preservation of area-based heritage. These characteristics can be applied as suggestions for the revitalization of the 'modern historical and cultural space' system implemented by South Korea.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.