• Title/Summary/Keyword: 저항 함수

Search Result 476, Processing Time 0.029 seconds

Study on Electrical Resistivity Pattern of Soil Moisture Content with Model Experiments (토양의 함수율에 따른 전기비저항 반응 모형 실험 연구)

  • Ji, Yoonsoo;Oh, Seokhoon;Lee, Heui Soon
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2013
  • Geophysical investigation in non-destructive testing is economically less expensive than boring testing and providing geotechnical information over wide-area. But, it provides only limited geotechnical information, which is hardly used to the design. Accordingly, we performed electrical resistivity experiments on large scale of soil model to analyze the correlation between electrical resistivity response and soil water contents. The soils used in the experiments were the Jumunjin standard sand and weathered granite soil. Each soil particle size distribution and coefficient of uniformity of experimental material obtained in the experiments were maintained in a state of the homogeneous. The specifications of the model used in this study is $160{\times}100{\times}50$(cm) of acrylic, and each soil was maintained at the height 30 cm. The water content were measured using the 5TE sensors (water contents sensors) which is installed 7 ~ 8 cm apart vertically by plugging to floor. The results of the resistivity behavior pattern for Jumunjin standard sand was found to be sensitive to the water content, while the weathered granite soil was showing lower resistivity over the time, and there was no significant change in behavior pattern observed. So, it results that the Jumunjin standard sand's particle current conduction was better than the weathered granite soil's particle through contact with the distilled water. This lab test was also compared with the result of a test bed site composed of similar weathered soil. It was confirmed that these experiments were underlying research of non-destructive investigation techniques to improve the accuracy to estimate the geotechnical parameter.

Determining Kernel Function of Apparent Earth Resistivity Using Linearization (선형화를 이용한 대지저항률의 커널함수 결정)

  • Kang, Min-Jae;Boo, Chang-Jin;Lee, Jung-Hoon;Kim, Ho-Chan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.454-459
    • /
    • 2012
  • A kernel function of apparent earth resistivity can be estimated using the apparent earth resistivity measured with Wenner's 4 point method. It becomes to solve a nonlinear system to estimate the kernel function of apparent earth resistivity. However it is not simple to get solution of nonlinear system with many unknown variables. This paper suggests the method of estimating kernel function by linearizing this nonlinear system. Finally, various examples of earth structure have been simulated to evaluate the proposed method in this paper.

DC 마그네트론 스퍼터법으로 Al 박막의 형성 시 실시간 전기저항 측정에 대한 연구

  • Gwon, Na-Hyeon;Ha, Sang-Hun;Park, Hyeon-Cheol;Jo, Yeong-Rae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.238-238
    • /
    • 2010
  • 최근 전자산업의 발전은 형상 면에서 경박 단소화로 급속하게 진행되고 있으며, 전자소자 내부에서의 배선재료로 사용되고 있는 알루미늄(Al) 박막의 두께 역시 얇아지고 있다. 두께가 20 nm 이하로 작은 극박막 범위에서 박막의 두께 증가에 따라 전기가 잘 흐르기 시작하는 박막의 최소두께로 정의 되는 유착두께를 실시간으로 측정하는 방법을 구현하고 임의의 금속박막과 기판의 조합에 있어서 각각의 재료에 대한 유착두께를 제공함으로써 향후 미세전자소자의 제작시 배선 재료의 선택에 대한 기초자료를 축적할 수 있다. 또한 금속박막의 증착공정 직전에 기판을 표면처리 하여 기판을 활성화시킬 때 표면처리가 박막의 유착두께에 미치는 영향에 대해 박막의 미세구조 변화 관점에서 연구함으로써 여러 가지 금속박막에 대한 유착두께를 줄일 수 있는 방법을 도출 할 수 있다. 본 연구에서는 유리 기판 위에 사진 식각 공정으로 패턴을 형성하고 패턴이 형성된 유리 기판은 스퍼터에 연결된 4 point probe에 구리 도선으로 연결한 후 DC 마그네트론 스퍼터법으로 Al을 증착하면서 실시간으로 시간에 따른 전기저항을 측정을 하였다. 이때 스퍼터 내부 진공도는 $4.6\;{\times}\;10^{-5}\;torr$ 까지 낮춰준 후 Al을 증착 할 때 진공도는 $1.1\;{\times}\;10^{-2}\;torr$로 맞춰주고 Ar 가스를 20 sccm 넣어준다. 1초 간격으로 전기저항을 측정한 결과 25초대에 전기저항이 급격히 감소하였으며 이때 Al 박막의 두께는 $120{\AA}$ 이고 이 두께에서부터 전류의 흐름이 좋은 것을 알 수 있다. 박막 두께에 따른 특성을 알기위해 UV 영역의 빛을 사용하는 광전자 분광기(Photoelectron Spectrometer)를 이용해 일함수를 측정하였다. Al 의 일반적인 일함수는 4.28 eV 이며, 두께가 $120{\AA}$일 때의 일함수는 4.2 eV로 거의 비슷한 값을 얻었다. 전류가 잘 흐르기 전인 12초대에서 두께가 $60{\AA}$일 때 일함수는 4.00 eV 이고 전류가 흐르기 시작한 후 50초대에서 Al 박막 두께가 $200{\AA}$ 일 때 일함수는 4.28 eV 로 일반적인 Al의 일함수와 같은 값을 얻을 수 있었다. 광전자 분광기술은 전자소자에서 중요한 전자의 성능예측에 도움을 줄 수 있으며 물질의 표면에서 더욱 다양한 정보를 얻을 수 있다. 또한 실시간 전기저항 측정을 통한 금속박막의 전기전도 특성과 미세구조에 대한 기초 자료를 제공함으로써 신기술 발전에 공헌할 것이다.

  • PDF

A Study on the Correlation between Electrical Resistivity and Properties of Contaminated Soils (오염지반의 전기비저항치와 토성과의 상관성 연구)

  • 윤길림;이영남
    • Geotechnical Engineering
    • /
    • v.14 no.2
    • /
    • pp.79-92
    • /
    • 1998
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and properties of contaminated soils. Three kinds of sandy soils sampled and leachate from an industrial waste landfill were mired to model the contaminated soils. Electrical resistivity of soils was measured by using a simulated resistivity cone penetrometer probe. In the experiments. the electrical resistivity was observed by changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

Analysis of the Electromagnetic Scattering of Resistive Strip Grating with Uniform Resistivity on a Grounded Dielectric Layer - H-Polarization Case - (접지된 유전체 위의 저항율이 일정한 저항띠 격자구조에 대한 전자파 산란 해석 - H-분극인 경우 -)

  • Tchoi Young-Sun;Yang Seung-In
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.3A
    • /
    • pp.321-327
    • /
    • 2006
  • In this paper, when a H-polarized plane wave is incident on the grating consisting of uniform resistive strips, electromagnetic scattering is analyzed using the moment of methods (MoM). The current density of each resistive strip on a grounded dielectric plane is fixed by zero at both edges. To satisfy the condition at both ends of each resistive strip, the induced surface current density is expanded in a series of cosine and sine functions. The scattered electromagnetic fields are expanded in a series of floquet mode functions. The boundary conditions are applied to obtain the unknown current coefficients. According to the variation of the involving parameters such as strip width and spacing and angle of the incident field, numerical simulations are performed by applying the Fourier-Galerkin moment method. The numerical results of the normalized reflected power for resistive strips case for zero and several resistivities are obtained.

A Study on the Secure Double Pipe Hash Function (안전한 이중 파이프 해쉬함수에 관한 연구)

  • Kim, Hie-Do
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.201-208
    • /
    • 2010
  • The classical iterated hash function is vulnerable to a multi-collision attack. Gauravaram et al. proposed 3C and 3C+ hash functions, in which an accumulation chain is added to usual Merkle-Damgard changing. Their goal is to design composition schemes resistant to generic attacks of Joux's type, but Joscak and Tuma have shown that 3C and 3C+ schemes are not better than Merkle-Damgard scheme in term of security against multi-collision attacks under some mild assumptions. In this dissertation, in order to increase security of 3C hash function, we proposed secure double pipe hash function which was effectively using XOR and XNOR operations per blocks of message. We seek to improve on the work of Lucks in a way. Proposed secure double pipe hash function takes resistance to multi-block collision, fixed point and pre-image attacks.

Kiln Drying Schedule Modification for Pitch Pine Using Drying Resistance (리기다소나무의 건조저항(乾燥抵抗)을 이용한 건조(乾燥)스케쥴 개량(改良))

  • Lee, Kyung-Sub;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.69-78
    • /
    • 1988
  • For the modification of kiln drying schedule, rela ons between drying resistance R and moisture content or drying times were found 2.5cm-and 5.0cm-thick pitch pine (Pinus rigida Mill.) board and dimension lumber by the conventional kiln drying schedule until the average moisture content was 10%. The results of this study were as follows. 1. Drying resistance increased curvilinearly as moisture content decreased, and was higher for dimension lumber than for board at a given moisture content. The relationships between drying resistance and moisture content for the conventional kiln drying schedule and thickness of lumber were 1) $R_{2.5}=6.795\times10^3M^{-1.27^{**}}$ for 2.5cm-thick board by the conventional kiln drying schedule. 3) $R_{5.0}=5.206\times10^4M^{-1.55^{**}}$ for 5.0cm-thick dimension lumber by the conventional kiln drying schedule. 2. As drying time increased, moisture content decreased and drying resistance increased at the same time. Gradient of slope for dimension lumber was gentler than board. 3. The predicted drying times to 10% moisture content with the conventional kiln drying schedule were a little shorter than actual drying times with relatively small error. 4. It is necessary for the conventional kiln drying schedule to be modified to provide the desired final moisture content at minimum drying time with no significant degrade under severe drying conditions. 5. The kiln factors for 2.5cm-thick board and 5.0cm-thick dimension lumber with the conventional kiln drying schedule were 1.112, 1.136, respectively.

  • PDF

Analytical Expressions of Temperature Dependent Breakdown Voltage and On-Resistance for Si Power MOSFETs (실리콘 전력 MOSFET의 온도 관련 항복 전압과 ON 저항을 위한 해석적 표현)

  • 정용성
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.5
    • /
    • pp.290-297
    • /
    • 2003
  • Analytical Expressions of temperature dependent breakdown voltage and on-resistance for silicon power MOSFETs are induced by employing the temperature dependent effective ionization coefficient extracted from temperature dependent ionization coefficients for electron and hole, and electron mobility in silicon. The analytical results for temperature dependent breakdown voltage are compared with experimental results for tile doping concentration, 4x10$^{14}$ cm$^{-3}$ , 1x10$^{15}$ cm$^{-3}$ , 6x10$^{16}$ cm$^{-3}$ respectively. The variations of temperature dependent on-resistance and breakdown voltage dependent ideal specific on-resistance are also compared with the ones reported previously. Good fits with the experimental results ate found for the breakdown voltages within 10% in error for the temperature in the range of 77~300K at each doping concentration.

Apparent Soil Resistivity Calculation Using Complex Image Method (복소수이미지 방법을 이용한 겉보기 대지저항률 계산)

  • Kim, Ho-Chan;Boo, Chang-Jin;Kang, Min-Jae
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.318-321
    • /
    • 2019
  • The apparent soil resistivity is used for estimating multilayer soil parameters, such as, layer's depth and soil resistivity. The apparent soil resistivity can be measured, and also can be calculated if soil parameters are given, becacuse the apparent soil resistivity is a function of these parameters. Therefore, any optimization algorithms can be used to find these parameters which make the calculated apparent soil resistivity close to the measured one. The equation for calculating the apparent soil resistivity is complicated and time consumed, because it is composed of an infinite integral which includes a zero order Bessel's function of the first kind. In this paper, a fast algorithm for calculating the apparent soil resistivity of horizontal multilayer earth structure has been presented using complex image method.