• Title/Summary/Keyword: 저항 요소

Search Result 933, Processing Time 0.031 seconds

Analytical Study on Structural Behaviors of Post-Tensioned Column-Base Connections for Steel Modular Structures (철골 모듈러 구조물의 포스트텐션 기둥-바닥 접합부 거동에 대한 해석적 연구)

  • Choi, Kyung-Suk;Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.6
    • /
    • pp.427-435
    • /
    • 2020
  • Modular structures are relatively lightweight compared to reinforced-concrete or steel structures. However, it is difficult to achieve structural integrity between the columns of unit modules in a modular structure, which causes undesirable effects on the lateral force resistance capacity against wind and earthquake loads. This is more prominent in modular structures whose overall heights are greater. Hence, a post-tensioned modular structural system is proposed herein to improve the lateral force resistance capacity of a typical modular structure. A post-tensioned column-base connection, which is the main component of the proposed modular structural system, is configured with shapes and characteristics that allow inducing self-centering behaviors. Finite element analysis was then performed to investigate the hysteretic behaviors of the post-tensioned column-base connection. The analysis results show that the hysteretic behaviors are significantly affected by the initial tension forces and beam-column connection details at the base.

A Study on the Identification of Equivalent Uniform Soil Model for Grounding Design of 500[tV] Transmission Towers (500[kV] 송전철탑 접지설계를 위한 다층토양구조의 균일매질 등가화에 관한 연구)

  • Choi, Jong-Kee;Lee, Sung-Doo;Lee, Dong-Il;Jung, Gil-Jo;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.22-28
    • /
    • 2005
  • The electrical characterstic of earth is the most dominant factor for grounding design and an earth is typically represented by a uniform medium with the specific earth resistivity, which is unique for a specific site. For a hand-working grounding design using a specific earth resistivity requires a process converting a real earth of complex medium into a simple uniform medium In this paper, we suggest a procedure to convert a multi-layered earth s into a simpler uniform earth for grounding design of Myanmar 500[kV] transmission towers.

Comparison of Grounding System Performance by Analysing Soil Laver Structures (대지지층구조의 분석유형에 따른 접지성능 비교 평가)

  • Cho, D.H.;Lee, K.S.;Jung, C.H.;Rhee, E.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.80-83
    • /
    • 2009
  • 현장 대지구조의 측정과 분석은 정확하고 신뢰성 있는 접지시스템의 설계와 시공에 매우 중요하며, 특히 대지 구조의 분석은 접지방식의 선정과 시공에 있어 절대적인 요소이다. 현장 측정 대지저항률의 실제적 분석을 통해 더 정확한 접지설계와 접지의 효율성을 높일 수 있으며, 시공 후 접지성능의 설계 오차를 최소화할 수 있게 된다. 대지는 다양한 형태의 지층과 구조로 이루어져 있으며, 접지설계의 신뢰성과 정확성은 대지 조건을 얼마나 현장 지질 조건에 가깝게 모델링 하는가에 달려있다. 현장 대지구조 및 지질 특성에 가깝게 분석하여 적용된 접지 설계는 시공 오류의 최소화, 성능의 안정화 그리고 비용의 절감은 물론 운용 설비의 운용 품질을 높여 주게 된다. 본 연구에서는 현장에서 측정된 대지저항률을 수직 지층와 수평지층 구조로 분석하여 그 결과를 비교하였고, 분석된 각각의 구조 대지저항률을 적용하여 접지시스템을 설계 비교하였다. 또한 설계된 접지시스템을 현장에 시공하여 측정된 결과값을 수직구조의 접지 설계치와 수평구조의 접지 설계치를 비교하므로써, 이를 통해 대지구조의 유형분석에 따른 접지설계의 신뢰성과 오류를 최소화하기 분석방안을 제시하였다.

  • PDF

Effects of deposition conditions on physical properties and stresses of $(AI, SI)_{1-x}O_x$ and Pt thin films (증착 조건이 $(AI, SI)_{1-x}O_x$박막과 Pt 박막의 물성 및 응력 변화에 미치는 영향)

  • Lee, Jae-Seok;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.6 no.9
    • /
    • pp.937-942
    • /
    • 1996
  • 박막 공정 및 마이크로머시닝(micromachining)기술에 의해 제작되는 마이크로 가스 센서는 고온 동작이 필수불가결하며 이 때 안정된 출력을 얻기 위해서 센서 저항 변화에 영향을 줄 수 있는 응집화 현상이 발생하지 말아야 한다. 본 연구에서는 고온 동작시 응집화의 구동력으로 작용하는 여러 요소중의 하나인 응력(stress)을 줄이기 위해서 인가 전력 밀도, 기판온도, 증착 압력 등을 증착 변수로 하여 증착 조건이 (AI, SI)1-xOx박막과 Pt 박막의 제반 물성 및 응력변화에 미치는 영향에 대하여 연구하였다. (AI, SI)1-xOx박막의 증착 속도와 굴절율 값은 O2분압과 기판 온도가 증가할수록 감소하였으며 응력은 O2분압이 증가함에 따라 인장에서 압축으로 전환된 후 증가하였다. Pt 박막의 경우, 인가 전력이 증가할수록 공정 압력이 감소할수록, 기판 온도가 감소할수록 증착 속도는 증가하였으며 전기 비저항은 감소하였다. Pt 박막의 응력은 인가 전력이 증가할수록, 공정 압력이 증가할수록, 기판 온도가 증가할수록 압축에서 인장의 방향으로 전환된 후 증가하였으며 박막의 전기비저항 및 증착속도에 크게 의존하는 것으로 분석되었다.

  • PDF

Annealing Effects on VOx Thin Film Deposited by DC Magnetron Sputtering Method

  • Park, Il-Mong;Han, Myeong-Su;Han, Seok-Man;Go, Hang-Ju;Kim, Hyo-Jin;Sin, Jae-Cheol;O, Tae-Seung;Kim, Dong-Il
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.223-223
    • /
    • 2011
  • 적외선 감지기로 사용되는 microbolometer 소자재료로 VOx 또는 비정질 Si이 가장 많이 사용된다. 그 중에서 VOx 물질은 온도저항계수 즉, TCR이 높고 감지도가 우수하기 때문에 비냉각 적외선 검출기에 많이 응용된다. Microbolometer 검출기는 그 응답도는 micromachining 공정에 의해 좌우되는 열 고립구조에 의해 좌우된다. 특히 TCR 값이 크고, 열시상수 값이 작을수록 양질의 감지도를 얻을 수 있으므로 재료의 선택 및 공정이 매우 중요하다. 따라서 본 연구에서는 비냉각 적외선 감지소자로 사용되는 VOx 박막을 DC Sputtering을 사용하여 증착하였으며, 그 특성을 조사하였다. MEMS 공정에 의한 센서의 제작은 적외선을 흡수하여 저항변화를 읽어내어 판독하는 Readout IC(ROIC) 위에 행해진다. Monolithic 공정에 의해 이러한 ROIC 위에서 공정이 동시에 행해지므로 공정온도는 매우 중요한 요소로 작용한다. 따라서 증착된 VOx 박막의 열처리 효과를 연구하였다. 열처리 온도는 $250^{\circ}{\sim}420^{\circ}C$, 열처리 시간은 20~80 min 까지 변화시켰다. 갓 증착된 VOx 박막의 저항은 약 200 $k{\Omega}$이였으며, TCR은 -1.5%/$^{\circ}C$로 나타났다. 열처리 온도가 증가함에 따라 TCR 값은 증가하였으며, 열처리 시간이 증가할수록 역시 TCR 값이 증가하는 경향을 보였다. 열처리 온도 320$^{\circ}C$, 열처리 시간 40 min에서 TCR 값은 약 -2%/$^{\circ}C$의 값을 얻을 수 있었다. 이러한 성능의 VOx 박막을 이용하여 비냉각형 microbolometer 검출소자를 열변형없이 공정을 수행할 수 있을 것으로 기대한다.

  • PDF

Design Comparison of Totally Prefabricated Bridge Substructure Systems Designed by Present Design and LRFD Methods (현행설계법 및 하중저항계수설계법에 의한 완전 조립식 교량 하부구조의 설계결과 비교)

  • Kim, Tae-Hoon;Kim, Young-Jin;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.11-22
    • /
    • 2011
  • The design comparison and nonlinear analysis of totally prefabricated bridge substructure systems are performed. The prefabricated bridge substructures are designed by the methods of present design and load and resistance factor design (LRFD). For the design, the current Korea Highway Bridge Code (KHBD), with DB-24 and DL-24 live loads, is used. This study evaluates the present design method of KHBD (2005) and AASHTO-LRFD (2007) for totally prefabricated bridge substructure systems. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures, was used.

Applicability of Existing Formulae for Composite Roughness (기존 복합 조도계수 산정식의 적용성)

  • Kim, Ji-Sung;Lee, Chan-Joo;Kim, Keuk-Soo;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1084-1088
    • /
    • 2010
  • 일반적으로 자연하천에서는 횡방향 흐름저항 요소가 매우 다를 수 있다. 이러한 하천은 흐름저항 요인에 따라 몇 개의 소단면으로 구분될 수 있으며, 1차원 해석을 위해서는 단면 전체를 대표하는 복합 조도계수(composite roughness coefficient)를 사용함으로써 수위 또는 평균유속의 계산이 가능해 진다. 복합 조도계수는 각 소단면의 면적(A), 윤변(P), 또는 동수반경(R)을 적절히 조합하여 각 소단면의 조도계수에 가중치를 부여하면서 계산되는데, 각 산정식들의 개발과정에 도입된 가정 조건에 따라 상이한 가중치를 부여하게 되며, 일부 산정식들에서는 횡방향으로 동일한 재료로 구성된 조건에서도 복합 조도계수 산정 결과는 하상재료에 의한 조도계수와 다른 값을 산정하게 된다. 본 연구에서는 13개의 기존 복합 조도계수 산정식을 이론적으로 검토하였고, 소규모 실내 수리실험자료로부터 실측 복합 조도계수와 계산된 값을 비교 분석하였으며, 소단면 분할방법에 의한 기존 산정식의 적용성을 분석하였다. 분석결과, 윤변을 가중치로 사용하는 경우는 실측 복합 조도계수 그리고 각 산정식에 의한 계산 복합 조도계수의 차이가 비교적 작게 나타났으나 각 산정식의 가정조건에 유의하여야 하는 것으로 나타났다. 한편 단면적 또는 윤변과 동수반경을 조합하여 가중치로 사용하는 경우는 방법별로 큰 차이를 보이는 것으로 분석되었고, 그 원인은 단면분할 방법에 기인하므로 이러한 방법을 적용할 경우에는 소단면 분할방법에 특히 주의하여야 함을 알 수 있다.

  • PDF

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.

A Study on Ship Motion Measurement System Using ADIS16480 Inertial Measurement Unit (ADIS16480 관성측정장치를 이용한 선체 운동 측정 시스템에 관한 연구)

  • Kim, Daejeong;Yim, Jeong-Bin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.270-270
    • /
    • 2019
  • Although the Inertial Measurement Unit is applied to a variety of applications such as ships, submarines, and aircrafts, it is mainly used in the attitude measurement area. But since such equipment is expensive, it has been used only in special fields. In this study, the ship's seaworthiness is verified by measuring the speed, direction, gravity, and acceleration of the ship in real time using a low-cost Inertial Measurement Unit. A research method for estimating fIuid force coefficients was devised. Therefore, this study measured ship motion factors at sea, processed and analyzed the measured data, and evaluated the overall safety of the ship and estimated the resistance and steering performance of the ship.

  • PDF

Electrical Resistivity Tomography for Inverse Problem Using FEM (유한요소법을 이용한 전기 비저항 탐사법의 저항역산)

  • Lim, Sung-Ki;Kim, Min-Kyu;Jung, Hyun-Kyo;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.154-156
    • /
    • 1996
  • A new method for electric resistivity tomography(ERT) is developed for geophysical inverse problems by adapting the sensitivity analysis. The outputs of the potential electrodes are computed using two dimensional finite element method in the wave number space by Fourier transforming the governing equations. The resistance distribution in the region of interests, which makes the computed potential distribution coincide with the measured potential, is found by minimizing the objective function using an optimization method. In this process the sensitivity analysis is introduced in order to compute the derivatives of the objective function. And an adjoint variable method is used to save the computational efforts for sensitivity coefficients.

  • PDF