• Title/Summary/Keyword: 저항 시험

Search Result 2,143, Processing Time 0.026 seconds

The Effects of Substrate Bias Voltage on the Formation of $(ZnS)_{1-x}-(SiO_2)_x$ Protective Films in Phase Change Optical Disk by R.F. Sputtering Method. (R.F. 스퍼터링법에 의한 상변화형 광디스크의 $(ZnS)_{1-x}-(SiO_2)_x$ 보호막 제조시 기판 바이어스전압의 영향)

  • Lee, Tae-Yun;Kim, Do-Hun
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.961-968
    • /
    • 1998
  • In order to investigate the effects of substrate bias voltage on the formation of$ZnS-SiO_2$ protective film in phase change optical disk by R.F. magnetron sputtering method, thin dielectric film was formed on Si wafer and Corning glass by using ZnS(80mol%)-$SiO_2$(20mol%)t arget under argon gas. In this study, the Taguchi experimental method was applied in order to obtain optimum conditions with reduced number of experiments and to control numerous variables effectively. At the same time this method can assure the reproducibility of experiments. Optimum conditions for film formation obtained by above method were target RF power of 200 W. substrate RF power of 20 W, Ar pressure of 5 mTorr. sputtering time of 20 min.. respectively. The phase of specimen was determined by using XRD and TEM. The compositional analysis of specimen was performed by XPS test. In order to measure the thermal resistivity of deposited specimen, annealing test was carried out at $300^{\circ}C$ and $600^{\circ}C$. For the account of void fraction in thin film, the Bruggeman EMA(Effective Medium Approximation) method was applied using the optical data obtained by Spectroscopic Ellipsometry. According to the results of this work, the existence of strong interaction between bias voltage and sputtering time was confirmed for refractive index value. According to XRD and TEM analysis of specimen, the film structure formed in bias voltage resulted in more refined structures than that formed without bias voltage. But excess bias voltage resulted in grain growth in thin film. It was confirmed that the application of optimum bias voltage increased film density by reduction of void fraction of about 3.7%.

  • PDF

Partial Drainage Characteristics of Clayey Silt with Low Plasticity from the West Coast (서해안 저소성 점토질 실트 지반의 부분배수 특성)

  • Kim, Seok-Jo;Lee, Sang-Duk;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.9
    • /
    • pp.17-27
    • /
    • 2016
  • Parial drainage characteristics of clayey silt with low plasticity from the west coast (Incheon and Hwaseong) was analyzed using CPTU based existing correlation equations and compulsory replacement method. Generally, the estimated $OCRs={\kappa}{\cdot}((q_t-{\sigma}_{vo})/{\sigma}^{\prime}_{vo})$ using Powell and Quartman(1988) were higher than those obtained by the oeodometer tests. These trends were noticeable for the layers containing a lot of silty and sand soils. The assessment of partial drainage conditions was performed through Schnaid et al. (2004)'s equation; it is based on plotting the normalized cone resistance, $Q_t$ versus the pore pressure parameter, $B_q$ in combination with the strength incremental ratio, $s_u/{\sigma}^{\prime}_{vo}$ to the CPTU data. It is evident that more than half of the data fall in the range where $B_q$ < 0.3, corresponding to the domain in which the partial drainage prevails when testing normally consolidated soils at a standard rate of penetration (2 cm/s). To estimate the replacement depth of clayey silt with low plasticity, back analysis was carried out to evaluate the internal friction angle based on where the design depths are equal to the checked depths using bearing capacity equation. The internal friction angels obtained from the back analysis tended to increase as the plasticity index decreases, which is ranged approximately from ${\varphi}^{\prime}=2^{\circ}$ to ${\varphi}^{\prime}=7^{\circ}$.

Manufacturing of Metal Micro-wire Interconnection on Submillimeter Diameter Catheter (서브-밀리미터 직경의 카테터 표면 위 금속 마이크로 와이어 접착 공정)

  • Jo, Woosung;Seo, Jeongmin;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.29-35
    • /
    • 2017
  • In this paper, we investigated a manufacturing process of metal micro-wire interconnection on submillimeter diameter catheter. Over the years, flexible electronic researches have focused on flexible plane polymer substrate and micro electrode manufacturing on its surface. However, a curved polymer substrate, such as catheter, is very important for medical application. Among many catheters, importance of submillimeter diameter steerable catheter is increasing to resolve the several limitations of neurosurgery. Steering actuators have been researched for realizing the steerable catheter, but there is no research about practical wiring for driving these actuators. Therefore we developed a new manufacturing process for metal micro-wire interconnection on submillimeter diameter catheter. We designed custom jigs for alignment of the metal micro-wires on the submillimeter diameter catheter. An UV curing system and commercial products were used to reduce the manufacturing time and cost; Au micro-wire, UV curable epoxy, UV lamp, and submillimeter diameter catheter. The assembled catheter was characterized by using an optical microscope, a resistance meter, and a universal testing machine.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

Durability Characteristics of Ternary Cement Matrix Using Ferronickel Slag According to the Alkali-Activators (알칼리 활성화제 종류별 페로니켈슬래그를 사용한 3성분계 시멘트 경화체의 내구특성)

  • Cho, Won-Jung;Park, Eon-Sang;Jung, Ho-Seop;Ann, Ki-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.190-197
    • /
    • 2020
  • This paper evaluates the mechanical properties and durability of cement matrix blended with mineral admixtures and ferronickel slag(FNS) powder which is an industrial b y-product during ferronickel smelting process. The hydration heat, pore structure, compressive strength, length change, rapid chloride penetration test(RCPT), and freezing and thawing resistance of ternary blended cement matrix were investigated and compared with ordinary portland cement matrix. The result showed that the compressive strength of ternary blended cement matrix using ferronickel slag powder and mineral mixture was low in strength compared to the reference concrete, but recovered to a certain extent by using alkali activator. Length change of cement mortar using FNS powder have shown less shrinkage occurs than the reference specimen. In addition, irrespective of using the alkali-activators, all ternary mix are indicative of the 'very low' range for chloride ion penetrability according to the ASTM C 1202, and the freeze-thaw resistance also showed excellent results.

A Study on the Resistance of Stress Corrosion Cracking due to Expansion Methods for Steam Generator Tubes in Nuclear Power Plants (원전 증기발생기 전열관의 확관방법에 따른 응력부식균열 저항성 연구)

  • Kim, Young Kyu;Song, Myung Ho
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.149-157
    • /
    • 2014
  • The steam generator tubes of nuclear power plants have various types of corrosion failures during the plant operation. The stress corrosion cracking which occurs on the outer surface of tube is called the secondary side stress corrosion cracking and mainly occurs in the expansion-transition area of tube. The causes are the concentration of impurities by the sludge pile-up related to the geometry of its region and the residual stress by tube expansion in the process of steam generator manufacturing. Especially the directionality and sizes of residual stresses are differed according to the tube expansion methods and the direction and the frequency of tube cracks depend on their characteristics. In bases on the plant experiences, it is notified that circumferential cracks of tubes expanded with explosive expansion method are dominantly occurred compared to those of tubes done with hydraulic expansion one. Therefore in this study, according to tube expansion methods frequencies and sizes of tube cracks with specific direction are compared by means of accelerated immersion test and also the crack morphology and the specific chemicals from water-chemistry environment are observed through the fracture surface examination.

Characterization of Physical Factor of Unsaturated Ground Deformation induced by Rainfall (강우를 고려한 불포화 지반변형의 영향인자 평가)

  • Kim, Man-Il;Jeon, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.18 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • Geophysical survey for establishing a wide site for the distribution of water content, wetting front infiltration due to the rainfall, and distribution of groundwater level has been performed by using 8round penetration radar (GPR) method, electrical resistivity method, and so on. On the other hand, a narrow area survey was performed to use a permittivity method such as time domain reflectometry, frequency domain reflectometry, and amplitude domain reflectometry methods for estimating volumetric water content, soil density, and concentration of contaminant in surface and subsurface. The permittivity methods establish more corrective physical parameters than different found survey technologies mentioned above. In this study for establishment of infiltration behaviors for wetting front in the unsaturated soil caused by an artificial rainfall, soil physical parameters for volumetric water content, pore water pressure, and pore air pressure were measured by FDR measurement device and pore water pressure meter which are installed in the unsaturated weathered granite soil with different depths. Consequently, the authors were proposed to a new establishment method for analyzing the variations of volumetric water content and wetting front infiltration from the responses of infiltrating pore water in the unsaturated soil.

Influence of Deep Flooding on Rice Growth and Yield in Dry-seeded Paddy Field (벼 건답직파 재배시 심수관개가 생육과 수량에 미치는 영향)

  • 원종건;최충돈;이외현;김칠용;이상철
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.2
    • /
    • pp.166-172
    • /
    • 1997
  • This experiment was carried out to clarify the effect of the deep water irrigation on dry-seeded rice cultivation at the three different water managements-deep continuous flooding(DCF), water saving irrigation(WSI), ordinary irrigation(OI). The highest tillering numbers per $m^2$ of rice were 551, 466 and 455 in OI, WSI and DCF, respectively. The tillering number of rice plants were significantly reduced in DCF. Heading date was delayed and the total chlorophyll content in leaf after heading was higher in DCF than those in other irrigation methods. For the characteristics associated with lodging, the culm length in DCF was slightly elongated and the diameter of culm in DCF was thicker than that in WSI and OI. The breaking weight and bending moment in DCF also were higher than those in others. As the result, although the culm length in DCF was long, the lodging index was comparatively low. The panicle length in DCF was longer than in OI and WSI. The spikelet number per $m^2$ and 1,000-grain weight were the most in WSI, while panicle number, ripened grain ratio and grain weight were not significantly different. Longer panicle length and more spikelet number resulted in higher yielding capacity in DCF.

  • PDF

Evaluation of Thermal Insulation and Hypothermia for Development of Life Raft (해상 구명정의 단열성능평가 및 저체온증 예측 수치해석 연구)

  • Hwang, Se-Yun;Jang, Ho-Sang;Kim, Kyung-Woo;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.485-491
    • /
    • 2015
  • The technology review about risk of hypothermia of victim according to heat transfer characteristic of life raft and sea state can use accident correspondence of standing and sinking of ship. This study studied heat transfer characteristics required for the design of life raft and thermal insulation property analysis and evaluation methods. In addition, it is study for comprehend the risk of hypothermia and suggest analysis result that is experiment of thermal insulation property and body temperature property for decide of prediction the body temperature decline Thermal Analysis apply the finite element analysis method is comprehended the property of heat conductivity, convective effect of sea water and properties changes according to property of insulation material. it measure the heat flux with attach temperature sensor on body in order to comprehend the variation of body temperature with boarding a life raft experiment on a human body. This study validate results by comparing variation of temperature measured from experiment on a body with variation of temperature from finite element analysis model. Also, the criteria of hypothermia was discussed through result of finite element analysis.

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.