• Title/Summary/Keyword: 저항 분포도

Search Result 936, Processing Time 0.025 seconds

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Suggestion of the Modified Archie's Formula for Calculating Water Saturation of Clean Sandstone and Carbonate Rocks (청결 사암 및 탄산염암의 물 포화도 산출을 위한 수정 Archie 경험식의 제안)

  • Lee, Sang-Hee;Ko, Eun-Ji;Kim, Jin-Hoo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2015
  • The water saturation ($S_w$), which is very important to estimate hydrocarbon reserves in the reservoir, has been determined from resistivity index (RI) by using the Archie's formula. However, in many cases, it has been reported that n is not constant for a given formation and it could be varied with water saturation. In addition, it frequently happens that the line obtained by linear regression analysis on log-log scale does not pass through the origin. In order to overcome these drawbacks, we suggested a modified Archie's formula, which can handle almost all the RI vs. $S_w$ cross-plots whether the trend is straight or curved and whether it passes through the origin or not. We also demonstrated that how to determine conductivity exponent ${\mu}$, critical water saturation $S_c$, and saturation distribution factor b in the laboratory to use the modified Archie's formula. Since the modified Archie's formula takes into account pore structure, pore water distribution, and wettability of reservoir such as clean sandstone and carbonate rocks, it might improve field applicability.

Distribution of Bacterial Angular Leaf Spot of Strawberry and Characterization of Xanthomonas fragariae Strains from Korea (한국의 딸기세균모무늬병 발생분포 및 딸기세균모무늬병균 특성조사)

  • Yoon, Myung-Ju;Myung, Inn-Shik;Lee, Jae-Yeon;Kim, You-Shin;Lee, Yong-Hwan;Kim, Dae-Young;Lee, Young-Ki
    • Research in Plant Disease
    • /
    • v.22 no.1
    • /
    • pp.9-17
    • /
    • 2016
  • Nationwide survey for angular leaf spot (ALS) of strawberry caused by Xanthomonas fragariae, a quarantine disease in Korea, was performed in November 2012. In the survey, ALS was observed in eighty eight farmers' fields of Sukok, Jinju and Okjong, Hadong in Gyeongnam Province, and one field in Namwon of Jeollabuk Province. The infected field of Namwon closed immediately after the disease diagnosed ALS. In detailed survey of Sukok and Okjong areas during February 2012 to January 2015, ALS occurrence decreased from 45% farmer's fields on December 2012 to 5% on January 2015, and from 38% on November 2013 to 5% on January 2015, respectively. Phenotypic characteristics of the Korean strains were similar to those of the type strain of X. fragariae. A multilocus sequence analysis of Korean strains of X. fragariae was conducted using four genes; dnaK, fyuA, gyrB, and rpoD. All the Korean strains had the same sequences of the four genes. The concatenated sequences of the Korean strains shared 100% with that of the type strain of X. fragariae. All strawberry cultivars tested were susceptible to the strains of X. fragariae two weeks after inoculation. The inoculated sites were necrosis and expanded, which were rated 4 based on evaluation of inoculation site.

레이저 유도 형광법(Laser Induced Fluorescence)을 이용한 플라즈마 방전 표시기(Plasma Display Panel)내의 전계 측정에 관한 연구

  • 김정훈;이준학;최영욱;양진호;황기웅
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.232-232
    • /
    • 1999
  • 교류형 플라즈마 방전 표시기(AC Plasma Display Panel, AC PDP)에 사용되는 플라즈마는 그 부피가 너무 작아서 플라즈마에 변화를 일으키지 않고 그 물성을 관측하기란 쉬운일이 아니다. 그래서 주로 PDP 내의 물성을 관측하는 데 시뮬레이션에 의존하게 된다. 그 물성중에 PDP내의 전계 분포에 대한 정보는 방전의 형성 및 소멸에 대한 많은 단서를 제공하고 있다. 특히 AC PDP의 경우, 유전체에 형성되는 벽적하(wall charge)가 방전의 형성 및 PDP 구동에 중요한 역할을 하는데, 이는 PDP 내의 전계 분포를 살펴봄으로써 대략 예측할 수 있다. 본 연구에서는 시뮬레이션에 의존하지 않고, 직접 레이저 유도 형광법을 이용하여 AC PDP 내의 전계를 측정하였다. 방전 가스인 헬륨(He)의 에너지 준위는 전계의 크기에 따라 에너지 준위가 변화하여, Rydberg(n$\geq$8) 준위가 여러 개의 준위로 나누어지는 현상이 일어나는데, 이를 Stack 효과라고 한다. 따라서 전계의 세기가 커짐에 따라서 각 준위와 준위 사이 값(splitting)이 커지는데, 이를 이용하면 전계를 측정할 수 있다. 즉, 헬륨 원자를 여기시키는 레이저 파장을 변화시키면서 관측되는 레이저 유도 형광 신호를 관측하면, 준위의 splitting을 관측할 수 있다. 본 연구에서는 PDP 내의 전계의 시간적 변화를 관측하였다. 50%, 40kHz의 구형파를 PDP의 두 전극에 가하였을 때, 플라즈마가 켜진 상태뿐만 아니라 플라즈마가 꺼진 후에도 전계에 의한 Splitting 신호가 관측이 되었는데, 전계로 환산하였을 때, 그 값은 대략 수 kV/cm의 값을 갖았는데, 이는 wall charge에 의한 값으로 사료된다.결과로 생각되어진다.플라즈마의 강도값을 입력하여 플라즈마의 radiation을 검출하고, 스퍼터링 공정중 실질적인 in-situ 정보로 이용하였다. PEM을 통하여 In/Sn의 플라즈마 강도변화를 조사하였다. 초기 In/Sn의 플라즈마 강도(intensity)는 강도를 100하여, 산소를 주입한 결과, plasma intensity가 35 줄어들었고, 이때 우수한 ITO 박막을 얻을 수 있었다. Pulsed DC power를 사용하여 아크 현상을 방지하였다. PET 상에 coating 된 ITO 박막의 표면저항과 광투과도는 4-point prove와 spectrophotometer를 이용하여 분석하였고, AES로 박막의 두께에 따른 성분비를 확인하였다. ITO 박막의 광투과도는 산소의 유량과 sputter 된 In/Sn ion의 plasma emission peak에 따라 72%-92%까지 변화하였으며, 저항은 37$\Omega$/$\square$ 이상을 나타내었다. 박막의 Sn/In atomic ratio는 0.12, O/In의 비율은 In2O3의 화학양론적 비율인 1.5보다 작은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인 모양을 가지는 성장의 경우도 cluster 밀도, cluster 모양, cluster의 양 축 방향 길이 비, 양 축 방향의 평균 팔 넓이로부터 각 축 방향의 분산 장벽을 얻어낼 수 있을 것으로 보인다. 기대할 수 있는 여러

  • PDF

Protein Composition of Domestic and Glyphosate-Tolerant Soybean (국내산 및 제초제 내성 콩의 단백질 조성 분석)

  • Wei, Chun-Hua;Sok, Dai-Eun;Yang, Yun-Hyoung;Oh, Sang-Hee;Kim, Hyoung-Chin;Yoon, Won-Kee;Kim, Hwan-Mook;Kim, Mee-Ree
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.4
    • /
    • pp.470-475
    • /
    • 2006
  • In order to elucidate the differences of protein profiles among soybean cultivars, the protein composition of three conventional domestic soybean cultivars and two imported ones including glyphosate-tolerant HS2906 was analyzed by total nitrogen measurement, amino acid analysis and PAGE/densitometry. There were no statistically significant differences in the levels of any amino acid, including aromatic amino acids, between glyphosale-tolerant soybean and the conventional soybean WS82. In the extraction of protein, the SDS/buffer system was more efficient than the defatting/water system. The SDS-PAGE/densitometry analysis showed that there was a similar profile of proteins among cultivars, although the amount of total protein ranged from 380.2 mg/g to 423.9 mg/g. In addition, there was no discernable difference of protein profile between glyphosate- tolerant soybean (total protein amount, 380.2 mg/g) and the conventional soybean WS82 (390.2 mg/g), although the amount of ${\beta}$-conglycinin (55 kDa) was lower in glyphosate-tolerant soybean. Meanwhile, the amount of 25 kDa protein was greater in domestic soybean cultivars than imported ones. Thus, normal PAGE/ densitometry method would be useful to analyze the difference in protein profiles of soybean proteins, and furthermore Evaluate the protein profile of proteins between GMO and conventional soybean.

Corrosion Monitoring of Reinforcing Bars in Cement Mortar Exposed to Seawater Immersion-and-dry Cycles (해수침지-건조 환경에 노출된 모르타르속 철근의 부식속도 평가)

  • Kim, Je-kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.10-18
    • /
    • 2018
  • The primary purposes of this study are to understand a fundamental aspect of current uniformity around a reinforcing bar (rebar) in cement mortar, and to develop an accurate monitoring method in a wet-dry cycling process with the alternative current (AC) impedance method. Three cement mortar specimens with two embedded rebars were prepared in the laboratory. As a main variable, the distance between two rebars was designed to be 10, 20 and 30 mm with the same thickness of 20 mm. To simulate the corrosion of rebars in concrete structures in a marine environment, three cement mortar specimens were exposed to 15 wet-drying cycles (24-hour-immersion in seawater and 48-hour-drying in a room temperature) in the laboratory. It was observed that the potential level shifted to a noble value during corrosion potential monitoring, which is attributed to acceleration of dissolved oxygen diffusion at the drying process. AC impedance was measured in a frequency range from 100 kHz to 1 mHz on a wet-drying process. A theoretical model was proposed to explain the interface condition between the rebars and cement mortar by using the equivalent circuit consisting of a solution resistance, a charge transfer resistance and a CPE (constant phase element). It was observed that the diffusion impedance appeared in a low frequency range as corrosion of rebars progresses. At the drying stage of the wet-drying cycles, the currents line for monitoring tended to be non-uniform at the interface of rebar/mortar, being phase shift, ${\theta}$, close to $-45^{\circ}$.

Sheet Resistance of Ion Implanted Si(100) at Various Doses, Energies and Beam Currents (Si(100)에 이온 주입 시 에너지, 조사량과 빔 전류에 따른 면저항의 변화)

  • Kim, Hyung-In;Jeong, Young-Wan;Lee, Myeung-Hee;Kang, Suk-Tai
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.100-105
    • /
    • 2011
  • Simulations were performed using Crystal TRIM software under the same conditions used by previous researchers in order to clarify the mechanism that determines sheet resistance various doses, energies and beam currents. The results showed that the peak of the depth profile (Rp) in the same sample gradually shifts inward and damage increases near the surface as the energy increases for $As^+$ equal dose of $1{\times}10^{15}/cm^2$ implanted into Si(100) energies of 5, 10, and 15 keV. From a theoretical calculation of B+ ion implantation processes at energy of 20 keV using parameters that correspond to 1 mA and 7 mA beam currents with the same dose of $5{\times}10^{15}/cm^2$, it was found that the higher beam currents resulted in more damage near the surface (<100 nm). Likewise, In the simulations employing sets of doses ($1{\times}10^{15}$, $3{\times}10^{15}/cm^2$) and beam currents (0.8 mA, 8 mA), more damage was produced at larger doses and higher current. Thus, sheet resistance at the surface was reduced by the intensified damage from increases in beam energy, dose and beam currents.

Pullout Behavior of Mechanically Stabilized Earth Wall Abutment by Steel Reinforcement and Backfill Properties (금속 보강재와 채움재 특성에 따른 보강토교대의 인발거동 분석 연구)

  • Kim, Taesu;Lee, Soo-Yang;Nam, Moon S.;Han, Heuisoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.750-757
    • /
    • 2018
  • The mechanically stabilized earth wall abutment is an earth structure using a mechanically stabilized earth wall and it uses in-extensional steel reinforcements having excellent friction performance. In order to analyze the pullout behavior of in-extensional steel reinforcements usually applied on the mechanically stabilized earth wall abutment, effects of stiffness and particle-size distributions of backfills and also horizontal spacings were considered in this study. As a result of parametric analyses, the highest pulling force acted on the uppermost reinforcement, and the stiffness and the particle-size distributions of the backfill significantly affected the pulling resistance of the reinforced soils. The internal friction angle of backfills should be at least 25 degrees, the coefficient uniformity factor should be at least 4, and the horizontal spacing of the uppermost steel reinforcement should be less than 25cm. Therefore, in order to secure the pullout resistance of the reinforced soil, it is necessary a properly spacing of reinforcement and more strict quality control for the backfill.

Electrochemical Characteristics of Electrode by Various Preparation Methods for Alkaline Membrane Fuel Cell (알칼리막 연료전지용 전극의 제조방법에 따른 전기화학적 특성 분석)

  • Yuk, Eunsung;Lee, Hyejin;Jung, Namgee;Shin, Dongwon;Bae, Byungchan
    • Journal of the Korean Electrochemical Society
    • /
    • v.24 no.4
    • /
    • pp.106-112
    • /
    • 2021
  • Catalyst poisoning by ionomers in membrane electrode assemblies of alkaline membrane fuel cells has been reported recently. We tried to improve the membrane electrode assembly's performance by controlling the solvent's ratio during electrode manufacturing. 4 Different mixing ratios of N-Methyl-2-pyrrolidone (NMP) and ethylene glycol (EG) gave four different cathode electrodes with platinum and Fuma-Tech ionomers. The electrode with higher EG improved polarization performance by about 36% compared to the NMP-based commercial ionomer. The dependence of the ionomer's dispersibility on the solvent seems responsible for the difference, which means that the non-uniform distribution of ionomers improves the performance of the electrode. High-frequency resistance, internal resistance corrected polarization curve, Tafel slope, mass activity, and impedance spectroscopy characterized the electrode. We can find that the existence of poor solvent improves cathode electrode performance. It seems to be the result of reduced poisoning of the catalyst according to the particle size distribution of the ionomer.

Monitoring the Structural Behavior of Reinforced RC Slabs Using Optical Fiber-embedded CFRP Sheets (광섬유 매립 CFRP 시트를 활용한 RC 슬래브의 구조적 거동 모니터링 기술 개발)

  • Kim, Jaehwan;Jung, Kyu-San;Kim, Byeong-Cheol;Kim, Kun-Soo;Park, Ki-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.311-322
    • /
    • 2022
  • This study performed 4-point flexural tests of reinforced concrete to which was attached a distributed optical fiber sheet and carbon fiber reinforced polymer (CFRP) sheets in order to assess the effect of the CFRP sheets and the applicability of a BOTDR sensor simultaneously. To evaluate the reinforcing effect, various degrees of CFRP sheet attachment were manufactured, and to evaluate the sensing ability, strains obtained from a BOTDR sensor were compared with strains measured from electric resistance strain gauges that were attached to the concrete surface. From the results, the reinforcing effects were evidently different according to the attachment type of the CFRP sheets, and it was confirmed that the main influencing factor on the reinforcing effect was the type of attachment rather than the attachment area. The reinforced concrete structural behavior was visualized with strains measured from the BOTDR sensor as load increased, and it was identified that load was concentrated in the CFRP reinforced area. Strains from the BOTDR sensor were similar to those from the electric resistance strain gauge; thereby a BOTDR sensor can be effective in the analysis of structural behaviorsof massive infrastructure. Finally, the strain from a BOTDR sensor was high where CFRP sheet fall-off occurs, and it would therefore be efficient to track local damage locations of CFRP sheets by utilizing a BOTDR sensor.