• Title/Summary/Keyword: 저온열원

Search Result 72, Processing Time 0.027 seconds

Performance Analysis of a Vapor Compression Cycle Driven by Organic Rankine Cycle (유기 랭킨 사이클로 구동되는 증기압축 냉동사이클의 성능 해석)

  • Kim, Kyoung Hoon;Jin, Jaeyoung;Ko, Hyungjong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.521-529
    • /
    • 2012
  • Since the energy demand for refrigeration and air-conditioning has greatly increased all over the world, thermally activated refrigeration cycle has attracted much attention. This study carries out a performance analysis of a vapor compression cycle (VCC) driven by organic Rankine cycle (ORC) utilizing low-temperature heat source in the form of sensible heat. The ORC is assumed to produce minimum net work which is required to drive the VCC without generating an excess electricity. Effects of important system parameters such as turbine inlet pressure, condensing temperature, and evaporating temperature on the system variables such as mass flow ratio, net work production, and coefficient of performance (COP) are thoroughly investigated. The effect of choice of working fluid on COP is also considered. Results show that net work production and COP increase with increasing turbine inlet pressure or decreasing condensing temperature. Out of the five kinds of organic fluids considered $C_4H_{10}$ gives a relatively high COP in the range of low turbine inlet pressure.

Characteristics of Thermodynamic Performance of Organic Flash Cycle (OFC) (유기 플래쉬 사이클(OFC)의 열역학적 성능 특성)

  • Kim, Kyounghoon;Jung, Youngguan;Park, Sanghee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.91-97
    • /
    • 2013
  • Recently a novel cycle named organic flash cycle (OFC) has been proposed which has improved potential for power generation from low-temperature heat sources. This study carries out thermodynamic performance analysis of OFC using various working fluids for recovery of low-grade heat sources in the form of sensible energy. Special attention is focused on the optimum flash temperature at which the exergy efficiency has the maximum value. Under the optimal conditions with respect to the flash temperature, the thermodynamic performances of important system variables including mass flow ratio, separation ratio, heat addition, specific volume flow rate at turbine exit, and exergy efficiency are thoroughly investigated. Results show that the exergy efficiency has a peak value with respect to the flash temperature and the optimum working fluid which shows the best exergy efficiency varies with the operating conditions.

Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures (스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험)

  • Sim, Kyuho;Jeong, Min-Seong;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

Experimental Feasibility Study on Low-Temperature Differential Stirling Engines with Water Spray Heat Transfer (스프레이 열전달을 이용한 저온도차 스털링 엔진의 실험적 개념 연구)

  • Jang, Seon-Jun;Lee, Yoon-Pyo;Sim, Kyuho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the results of an experimental feasibility study on low-temperature differential Stirling engines with water spray heat transfer. The water spray enhances the efficiency of the heat transfer from heat sources to the engine and reduces the performance degeneration due to the dead volumes of conventional heat exchangers. A test Stirling engine was developed and an experiment was conducted to determine the characteristics for the initial start-up, steady-state operation, and power output for various flow rates and temperatures of hot supply water. The test results showed that larger flow rates led to reductions in the minimum working temperature of the hot water at start-up. During a series of steady-state operations, higher flow rates and temperatures increased the working speed. Furthermore, the work per cycle and power output were also increased. Eventually, the test Stirling engine had a power level of 0.05 W. Based on this, further research will be conducted to obtain a higher power output and investigate various applications.

Practical Usage of Low-Temperature Metal Catalyst for the Destruction of Volatile Organic Compounds (VOCs) (휘발성 유기화합물(VOCs) 제거를 위한 저온금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.397-405
    • /
    • 2012
  • In this study, performance evaluation of newly developed technology for the economical and safe removal of volatile organic compounds (VOCs) coming out from electronic devices washing operation and offensive odor induction materials was made. Metal oxidization catalyst has shown 50% of removal efficiency at the temperature of $220^{\circ}C$. Composite metal oxidization catalyst applied in this study has shown that the actual catalysis has started at the temperature of $100^{\circ}C$. Comprehensive analysis on the catalyst property using Mn-Cu metal oxidization catalyst in the pilot-scale unit was made and the removal efficiency was variable with temperature and space velocity. Full-scale unit developed based on the pilot-scale unit operation has shown 95% of removal efficiency at the temperature of $160^{\circ}C$. Optimum elimination effective rates for the space velocity was found to be $6,000hr^{-1}$. The most appropriate processing treatment range for the inflow concentration of VOCs was between 200 ppm to 4,000 ppm. Catalyst control temperature showed high destruction efficiency at $150{\sim}200^{\circ}C$ degrees Celsius in 90~99%. External heat source was not necessary due to the self-heat reaction incase of VOCs inflow concentration is more than 1,000 ppm. Equipment and fuel costs compared to the conventional RTO/RCO method can be reduced by 50% and 75% respectively. And it was checked when there was poisoning for sulfide and acid gas.

Moisture Gettering by Porous Alumina Films on Textured Silicon Wafer (실리콘 표면에 증착된 다공성 알루미나의 수분 흡착 거동)

  • Lim, Hyo Ryoung;Eom, Nu Si A;Cho, Jeong-Ho;Choa, Yong-Ho
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.401-406
    • /
    • 2015
  • Getter is a class of materials used in absorbing gases such as hydrogen and moisture in microelectronics or semiconductor devices to operate properly. In this study, we developed a new device structure consisting of porous anodized alumina films on textured silicon wafer, which have cost efficiency in materials and processing aspects. Anodic aluminum oxide (AAO) with controlled pore sizes can be applied to a high-efficiency moisture absorber due to the high surface area and OH- saturated surface property. The moisture sorption capacity was 2.02% (RH=35%), obtained by analyzing isothermal adsorption/desorption curve.

Performance Analysis of Direct Expansion and Organic Rankine Cycle for a LNG Cold Power Generation System (LNG냉열발전시스템에 있어서 직접팽창 및 유기랭킨사이클의 운전성능평가)

  • Cho, Eun-Bi;Jeong, Moon;Hwang, In-Ju;Kang, Choon-Hyoung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • The liquefaction to produce LNG (liquefied natural gas) is the only practical way for mass transportation of natural gas across oceans, which accompanies considerable energy consumption in LNG plants. Power generation is one of the effective utilization ways of LNG cold energy which evolves during the vaporization process of LNG with sea water. In this work, performance analysis of two cold energy generation processes, direct expansion and organic Rankine cycles, were carried out by using Aspen HYSYS simulation. The results show that the performance of the organic Rankine cycle is superior to the direct expansion.

Thermo-Fluid Simulation for Flow Channel Design of 7kW High-Voltage Heater for Electric Vehicles (전기차용 7kW급 고전압 히터 유로 형상 설계를 위한 열유동 시뮬레이션)

  • Son, Kwon Joong
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.191-196
    • /
    • 2022
  • Unlike an international combustion engine car, a battery-powered electric vehicle requires an additional heat source for its heating system. A high-voltage coolant heater has the advantages of high efficiency and a wide operating temperature range. In its development, the geometry design of the coolant flow path is essential. This paper presents the thermal flow simulations of a 7kW high-voltage heater with symmetric serpentine flow channels arranged parallelly. The heater performance was evaluated from the simulation results in terms of the pressure and temperature differences and the flow uniformity. The proposed design showed a greater flow resistance and similar heat exchanging capability than the existing parallel serpentine design. It has the advantage of a relatively wide low-temperature surface area, where the control circuit board susceptible to high temperatures can be located.

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (축열형 지열원 냉난방 시스템의 단기 성능 특성 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.119-119
    • /
    • 2010
  • 무한 지속 가능한 지열 에너지를 활용한 공조시스템인 지열원 냉난방 시스템은 기존의 공조 시스템보다 열원이 안정적이기 때문에 높은 효율과 우수한 성능을 가지므로, 기후변화협약 대응의 주요수단으로서 기술개발과 보급이 증대되고 있다. 본 연구에서는 대수층 축열 지열원 열펌프 시스템에 대한 실증 연구를 통하여 대수층 축열 지열원 열펌프 시스템의 하절기 냉방 성능을 분석하였다. 대수층 축열 냉난방 시스템은 주입정과 양수정의 2개의 우물공이 설치되어 있으며, 겨울 난방 운전 중에 한 개의 우물공으로부터 지하수를 열펌프로 유입한 후 낮은 온도의 지하수를 타 우물공에 축열하고, 하절기에 겨울에 저온으로 축열된 우물공으로부터 지하수를 열펌프로 유입하여 온도가 증가된 지하수를 타 우물공에 주입한다. 즉, 계절별로 열펌프에서 생성된 냉수와 온수의 대수층 축열을 위하여 계절별로 주입정과 양수정이 바뀌게 된다. 본 연구의 대수층 축열 지열원 열펌프 시스템의 2009년 8월의 주요일자별 시스템 운전 중의 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 각각 4.7과 3.4이상의 우수한 성능을 나타냈다. 또한, 모든 일자에 대하여 외기온도가 $31.6^{\circ}C$$22^{\circ}C$까지 변화가 크게 나타났지만 열펌프 유닛 COP와 시스템 COP의 변화는 미소하였다. 이는 양수정으로부터의 지중 순환수가 운전기간 중에 $17.5^{\circ}C$로 일정하게 유지되었기 때문이다. 양수정과 주입정 사이에 5개의 관측공을 설치하였으며, 양수정 측에 인접한 관측공의 온도는 거의 변화가 없었으며, 단기간이지만 널리 사용되고 있는 수직밀폐형 시스템과 달리 지속적인 냉방운전 중의 양수 온도의 증가는 발생하지 않아 안정적인 성능을 나타냈다. 주입정에 인접한 모니터링 홀의 온도는 심도가 깊은 곳의 온도가 낮은 곳보다 높게 나타났다. 이는 냉방 운전 시 열펌프 유닛의 실외열교환기에서 지중 순환수가 냉매로부터 열을 취득하여 온도가 상승하면서 주입정측에 온열이 축열이 진행되었기 때문으로 분석되며, 하절기의 냉방 운전 시간이 증가할 경우 축열 효과는 더욱 증가할 것으로 예상된다. 양수정과 주입정 중간의 모니터링 홀의 온도는 2009년 8월 가동 중에 온도변화는 없었는데, 이는 양수정과 주입정 사이의 열간섭이 발생하지 않았기 때문으로 분석된다. 일자별로 운전 중의 열펌프 유닛 COP는 차이가 없었지만, 운전 및 정지 시간을 모두 포함한 시스템 소비전력과 냉방용량을 모두 합산하여 산정한 일일 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 일자별로 다소 차이가 발생하였는데, 이는 각 일자별로 열펌프 유닛 가동율의 차이로 인하여 열펌프 유닛 가동 전에 먼저 작동되는 지중순환펌프의 운전 소비전력의 차이와 열펌프의 단속운전 시의 열손실과 추거 소비전력의 차이 때문이다.

  • PDF

The Heat Pump Application to the Food Concentration (열 펌프의 식품 농축에의 이용 연구)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Kang, Tong-Sam;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.486-491
    • /
    • 1987
  • The performance and applicability to food concentration of heat pump were investigated. During heating the water of spa from $43^{\circ}C$ to $51^{\circ}C$, COP's of heat pump (R-12, 150 HP) were 4.03 at heating part and 3.5 at cooling part. And, the efficiency of compressor (${\alpha}$) was 0.477 While the city water was heated to $39^{\circ}C$ by heat pump (R-22, 10 HP), its COP's were 3.0 at heating part and 1.87 at cooling part. During concentrations sucrose solution by centrifugal evaporator (ALFA-LAVAL CO, CTIB) with heat pump, heat capacity for condensating water vapor was required greater 15% than the latent heat for concentrating and then the overall heat transfer coefficient was $1196\;Kcal/m^{2}.\;h.\;^{\circ}C$. When low temperature concentration ($30-35^{\circ}C$, 28-40 Torr) of garlic extract was carried out by the water of $60^{\circ}C$ and $15^{\circ}C$ adjusted by heat pump, the ratio of heat capacity for concentrating vs. that for condensating of water vapor was 0.961.

  • PDF