• Title/Summary/Keyword: 재카운터

Search Result 17, Processing Time 0.035 seconds

A Design of Lightweight RFID Authentication Protocol Errors Correction Using Re-Counter (재카운터를 이용해 오류를 수정하는 경량화 RFID 인증 프로토콜 설계)

  • OH, Gi-Oug
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.149-157
    • /
    • 2011
  • Passive tags are inferior to active tags in processing efficiency, so they have difficulty in largevolume processing. The proposed protocol reduces the volume of computation in passive tags and, at the same time, improves authentication for enhanced safety and security. That is, different from existing RFID protocols that return the same value even if an error happens when the reader reads a tag, the improved RFID security protocol returns a new value using a re-counter and processes the computation part of a tag in the reader or in a back.end system. Even if the information of a tag is acquired by an malicious way, it is not actual information but encrypted information that is not usable. In addition, even if tag information is read in sequence, it is changed in each read, so the protocol is safe from Location Tracking.

The Production of HBsAg in the Recombinant Yeast Cells (재조합 효모 세포내에서의 간염백신 생산)

  • Park, Cha-Yong;Lee, Hei-Chan
    • Microbiology and Biotechnology Letters
    • /
    • v.14 no.6
    • /
    • pp.455-460
    • /
    • 1986
  • Dane particle was prepared from the plasma of chronic HBsAg carrier with high levels of HBsAg activity. DNA extracted front Dane particle core after a DNA polymerase reaction with $\alpha$-($^{32}$P) dNTP, was identified as HBV DNA by liquid scintillation counter and agarose gel electrophoresis-G.M. counting. To produce Hepatitis B surface antigen for use as a vaccine against Hepatitis B virus infection, yeast strains harboring recombinant plasmid with Apase promoter was used. Recombinant plasmid was construced from pHBV 130 and pAN 82, transformed into E coli, and then transferred into yeast strains. HBsAg was produced by derepression in Burkholder minimal medium with controlled inorganic phosphate concentration. The kinetics of HBsAg production was also investigated. Total HBsAg activity increased rapidly between 3 and 6 hours after transfer to phosphate-free medium and reached a maximum at around 9th hour. The transfer into phosphate-free medium after 6 hours in high phosphate cell growth medium gave maximum activity.

  • PDF

The Importance and Performance Analysis of Service Encounter Quality by Types of Restaurants (레스토랑 유형별 서비스 인카운터 품질의 중요도 및 수행도 분석)

  • Jo, Mi-Na
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.8
    • /
    • pp.1076-1087
    • /
    • 2006
  • The purpose of this study was to identify critical control points of service encounter by types of restaurants in order to manage moment of truth when customers encounter services. Questionnaires were collected from 812 customers (aged 15 years or older) who had used restaurants in Seoul, from October 24, 2005 to November 6, 2005. The main results of this study were as follows: Statistically significant differences were shown between importance and performance of interaction quality, physical environment quality and outcome quality. Significant differences were also shown in importance and performance of interaction and physical environment quality, and performance of outcome quality by restaurant types but no significant difference was indicated in importance of outcome quality by restaurant types. That is, the importance of outcome quality, which means the quality of food, was regarded as important by customers who use restaurants regardless of types of restaurants. The result of examining interaction quality showed that family restaurants managed waiting customers quite well and provided information on the Internet homepage. Performance of responding to customers with complaints was rated the highest in family restaurants. Regarding physical environment quality, importance and performance scores significantly differed by types of restaurants in order of fine-dining restaurants, family restaurants, and fast-food restaurants. In terms of service encounter quality, items whose importance scores were high but performance scores were low in importance-performance analysis matrix were 'quality of provided food is always uniform' and 'the space between other tables is enough' for fine-dining restaurants. In family restaurants, 'size of chairs or tables is enough', and 'the space between other tables is enough' were included in the items, while 'interior facilities are attractive', 'size of chairs and tables is enough', and 'the space between other tables is enough' were included in the items in case of fast-food restaurants. A difference was indicated depending on types of restaurants.

Improving the Performance of TCP/RLP over CDMA Forward Link (CDMA 순방향 무선링크에서의 TCP/RLP 성능 향상에 관한 연구)

  • 송기영;박영근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5B
    • /
    • pp.369-380
    • /
    • 2003
  • In the CDMA wireless link, frame errors are correlated and burst because of fading. The implementation ability of RLP error recovery is dependent on the correlated frame errors. The (1,2,3) retransmission scheme, which is recommended as default in IS-707, is not adapted in high frame loss regime with strong correlations. By using the modified error recovery method, where the total number of retransmission attempts is the same and the retransmission is increased, the proposed retransmission scheme can efficiently recover frame errors than the (1,2,3) retransmission scheme. Since the modified scheme has longer transmission delay due to the increase of retransmission round, we propose the algorithm of retransmission failure prediction to improve the modified error recovery scheme. We simulate the modified error recovery scheme applying our algorithm and compare two schemes. (i.e. default scheme by IS-707 and modified scheme) not applying our algorithm. In the result, we show TCP performance improvement is better than default scheme by IS-707.

Efficient RFID Search Protocols Providing Enhanced User Privacy (강화된 사용자 프라이버시를 보장하는 효율적인 RFID 검색 프로토콜)

  • Lim, Ji-Hwan;Oh, Hee-Kuck;Nyang, Dae-Hun;Lee, Mun-Kyu;Kim, Sang-Jin
    • The KIPS Transactions:PartC
    • /
    • v.16C no.3
    • /
    • pp.347-356
    • /
    • 2009
  • In an RFID search protocol, a reader uses designated query to determine whether a specific tag is in the vicinity of the reader. This fundamental difference makes search protocol more vulnerable to replay attacks than authentication protocols. Due to this, techniques used in existing RFID authentication protocols may not be suitable for RFID search protocols. In this paper, we propose two RFID search protocols, one based on static ID and the other based on dynamic ID, which use counter to prevent replay attacks. Moreover, we propose a security model for RFID search protocols that includes forward/backward traceability, de-synchronization and forgery attack. Based on this model, we analyze security of our protocols and related works.

Static Corrective Controllers for Implementing Fault Tolerance in Asynchronous Sequential Circuits (정적 교정 제어기를 이용한 비동기 순차 회로의 내고장성 구현)

  • Yang, Jung-Min;Kwak, Seong Woo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2016
  • Corrective controllers enable fault diagnosis and tolerance for various faults in asynchronous sequential circuits without resort to redesign. In this paper, we propose a static corrective controller in order to decrease the size of the controller. Compared with dynamic controllers, static controllers can be made using only combinational circuits, as they need no inner states. We address the existence condition and design procedures for static corrective controllers that overcome state transition faults. To show the validity and advantage, the proposed controller is applied to an SEU error counter implemented on FPGA.

An Embedded Timing Loss Detector for Robust Data Transmission (데이터 전송을 위한 타이밍 손실 검출기)

  • 이용환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1404-1411
    • /
    • 1993
  • Unlike voice communication, data transmission, can be seriously affected by transient channel impairments. In some cases, timing synchronization between the transmitter and the receiver may not be recovered in the presence of these kinds of impairments without a forced reinitialization process. Therefore, it is highly desirable for data communication equipment to have an efficient timing loss detector for robust recovery. In this paper, one such detector is proposed for data transceivers haying a secondary channel embedded in the main channel. A known sequence multiplexed with the secondary channel data is repeatedly sent through the embedded secondary channel. For continuous watch-dog like operation, the detection is sequentially performed based on a modified up/down counter scheme. The performance of the proposed detector is analytically evaluated In closed form.

  • PDF

Satellite Battery Cell Voltage Monitor System Using a Conventional Differential Amplifier (종래의 차동증폭기를 사용한 인공위성 배터리 셀 전압 감시 시스템)

  • Koo, Ja-Chun;Choi, Jae-Dong;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.113-118
    • /
    • 2005
  • This paper shows a satellite battery cell voltage monitor system to make differential voltage measurements when one or both measurement points are beyond voltage range allowed by a conventional differential amplifier. This system is particularly useful for monitoring the individual cell voltage of series-connected cells that constitute a rechargeable satellite battery in which some cell voltages must be measured in the presence of high common mode voltage.

A Study on Counting Measurement of Cultural Infrastructure Visitors: Focused on the Wireless Signal-Based Measurement (무선신호기반 측정방식을 활용한 문화기반시설 이용자 현황 측정에 관한 연구)

  • Kim, Ji-Hak;Park, Geun-Hwa
    • Korean Association of Arts Management
    • /
    • no.59
    • /
    • pp.73-99
    • /
    • 2021
  • Free admission policies have been gradually extended for the public to use cultural facilities free of charge, which lowered the barriers to use those facilities and has a great effect on increasing visitor demands. However, the annual number of visitors which is open to the public isn't quite accurate and varies from institution to institution, which means just a head count. Especially people counter overestimates the number of visitors because it counts visitors in duplicate. Therefore, the purpose of this study is to prepare effective way of grasping the number of visitors using cultural infrastructure. First, comparable number of visitors should be measured by defining the notion of visitor clearly, which has been measured vaguely. Secondly, the problem of duplicate count, which is considered the most problematic, should be solved. Thirdly, the various analysis of visitor behavior should be conducted to provide a high-quality service. To work out the problems above, new measurement will be presented here. This study suggests a state-of-the-art wireless signal-based measurement that could eliminate the duplicate data by collecting MAC address -smart device's distinct signal value. And it also could analyze diverse visitor behaviors by understanding a flow of visitor traffic, duration of stay and revisitation. I would like to examine the possibility and effectiveness of this new measurement by testing it.

Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change. (IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석)

  • Kim, Jung In;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • Purpose The principle of nuclear medicine test is divided into two main categories: competition(radioimmunoassay, RIA) and noncompetitive reaction(Immunoradiometric assay, IRMA). It is known that the curve fitting method, which is commonly used in inspection field, uses Spline interpolation in RIA method and Linear interpolation method in IRMA method. Among them, the insulin test using the IRMA test showed a significant difference, especially at low concentrations, despite the same algorithm of linear interpolation between fully automated radio immunoassay analyzers. In this study, we aim to obtain results from applying two different of algorithm using fully automated radio immunoassay analyzers including Gamma pro, Gamma 10, Cobra, and SR300. Materials and Methods A total of 30 test samples were selected for the test of TSH, ferritin, C-peptide, and insulin serum levels. Test was performed by IRMA method. We compared the difference in the results of applying the linear interpolation method and the spline interpolation method to Gamma Pro, Gamma 10, Cobra, and SR300 equipment. Results Two-way ANOVA was used for statistical analysis. The significance level was applied as P <0.05. The results of TSH, ferritin, C-peptide, and insulin tests were compared between the fully automated radio immunoassay analyzers. There was a significant difference between ferritin, C-peptide, and insulin serum levels(P<0.001). TSH didn't show any significant different between the devices(P=0.29). In the difference between linear and spline interpolation, there was no significant difference between insulin test(P=0.08), TSH test(P=0.81), and Ferritin test(P=0.06). However, C-peptide test showed a significant difference(P=0.03). Especially, the insulin test showed significant difference in lower ranges. As a result of comparing and analyzing the difference between the two interpolation methods, the devices in the low concentration group showed significant difference(P<0.001). Conclusion In case of new equipment in the laboratory it is necessary to recognize that there is a difference in the curve fitting method for each automated radio immunoassay analyzers in the low concentration area when the principle of inspection is IRMA method.