• Title/Summary/Keyword: 재료 시험

Search Result 4,141, Processing Time 0.034 seconds

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

The effect of silane treatment timing and saliva contamination on shear bond strength of resin cement to porcelain (Silane의 처리시기와 타액오염이 도재-레진 시멘트의 전단 결합강도에 미치는 영향)

  • Ro, Young-Seon;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.61-69
    • /
    • 2009
  • Statement of problem: Porcelain veneers have become a popular treatment modality for aesthetic anterior prosthesis. Fitting porcelain veneers in the mouth usually involve a try-in appointment, which frequently results in salivary contamination of fitting surfaces. Purpose: An in vitro study was carried out to investigate the effect of silane treatment timing and saliva contamination on the resin bond strength to porcelain veneer surface. Material and methods: Cylindrical test specimens (n=360) and rectangular test specimens (n=5) were prepared for shear bond test and contact angle analysis. Whole cylindrical specimens divided into 20 groups, each of which received a different surface treatment and/or storage condition. The composite resin cement stubs were light-polymerized onto porcelain adherends. The shear bond strengths of cemented stubs were measured after dry storage and thermocycling (3,000 cycles) between 5 and $55^{\circ}C$. The silane and their reactions were chemically monitored by using Fourier Transform Infrared Spectroscopy analysis (FTIR) and contact angle analysis. One-way analysis of variance (ANOVA) and Dunnett's multiple comparison were used to analyze the data. Results: FT-IR analysis showed that salivary contamination and silane treatment timing did not affect the surface interactions of silane. Observed water contact angles were lower on the saliva contaminated porcelain surface and the addition of 37% phosphoric acid for 20 seconds on saliva contaminated porcelain increased the degree of contact angle. Silane applied to the porcelain, a few days before cementation, resulted in increasing the bond strength after thermocycling. Conclusion: Within the limitation of this study, it can be concluded that it would be better to protect porcelain prosthesis before saliva contamination with silane treatment and to clean the contaminated surface by use of phosphoric acid.

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

Retentive bond strength of fiber-reinforced composite posts cemented with different surface treatments (Fiber reinforced composite post의 표면 처리에 따른 접착 강도)

  • Roh, Hyunsik;Noh, Kwantae;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • This study will evaluate the effectiveness of various pretreatments when fiber-reinforced composite (FRC) post is bonded to endodontically treated tooth with resin cement. Materials and methods: Canal shaping of FRC post (DT Light post, Size 3, Bisco Inc., Schaumburg, IL, USA) was performed on endodontically treated premolars at 1.5 cm from CEJ. Samples were divided into 6 groups of surface treatment after conventional washing and drying to the canal. Total of 24 FRC posts were randomly divided into 6 groups of surface treatment as follows: Group C: control - no surface treatment, Group A: airborne-particle abrasion (Cojet sand, 3M ESPE), Group S: silanization (Bis-silane, Bisco Inc.), Group M: universal primer (Monobond-plus primer, Ivoclar Vivadent Inc.), Group AS: silanization after airborne-particle abrasion, Group AM: universal primer treatment after airborne-particle abrasion. Pretreated fiber posts were cemented with resin-based luting material and photo-polymerized and cut to the thickness of 1 mm. Push-out test using a universal testing machine was performed. Bonding failure strength of post dislodgement was measured and the type of bonding failure was classified. Data were analyzed with Kruskal-Wallis test and multiple comparison groups were performed using Tukey HSD value of rank test (${\alpha}=0.05$). Results: Group AS showed significantly highest bonding strength. Group S, group AM, group A, and group M showed lower bonding strength in order. The control group showed the lowest bonding strength. Conclusion: Surface treatment with silane showed to be the most effective of the surface pretreatment methods for cementation of FRC post. Surface treatment with universal primer showed no significant difference compared with no surface treatment group as for bonding strength.

Rheological properties of dental resin cements during polymerization (치과용 레진 시멘트의 유변학적 성질)

  • Lee, Jae-Rim;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.82-89
    • /
    • 2014
  • Purpose: The purpose of this study was to observe the change of viscoelastic properties of dental resin cements during polymerization. Materials and methods: Six commercially available resin cement materials (Clearfil SA luting, Panavia F 2.0, Zirconite, Variolink N, RelyX Unicem clicker, RelyX U200) were investigated in this study. A dynamic oscillation-time sweep test was performed with AR1500 stress controlled rheometer at $32^{\circ}C$. The changes in shear storage modulus (G'), shear loss modulus (G"), loss tangent (tan ${\delta}$) and displacement were measured for twenty minutes and repeated three times for each material. The data were analyzed using one-way ANOVA and Tukey's post hoc test (${\alpha}$=0.05). Results: After mixing, all materials demonstrated an increase in G' with time, reaching the plateau in the end. RelyX U200 demonstrated the highest G' value, while RelyX Unicem (clicker type) and Variolink N demonstrated the lowest G' value at the end of experimental time. Tan ${\delta}$was maintained at some level and reached the zero at the starting point where G' began to increase. The tan ${\delta}$and displacement of the tested materials showed similar pattern in the graph within change of time. The displacement of all 6 materials approached to zero within 6 minutes. Conclusion: Compared to other resin cements used in this study, RelyX U200 maintained plastic property for a longer period of time. When it completed the curing process, RelyX U200 had the highest stiffness. It is convenient for clinicians to cement multiple units of dental prostheses simultaneously.

Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown (완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구)

  • Jang, Soo-Ah;Kim, Yoon-Young;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.160-166
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. Materials and methods: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and $6^{\circ}$ taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$) and t-test (${\alpha}=.05$) were used. Results: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P<.05), and the value of the test 2.3.4.5 groups (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) increased as thickness increased, but no significant difference were found with the groups (P>.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). Conclusion: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.

Investigation on Korean Local Maize Lines VI. Use of a Korean Local Maize Line for Silage Production (재래종 옥수수 수집종에 대한 특성조사 제6보 청예를 위한 재래종 옥수수의 이용에 관한 연구)

  • Choe, B.H.;Park, J.S.;Kim, Y.R.;Chung, S.K.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.26 no.3
    • /
    • pp.251-256
    • /
    • 1981
  • Silage yield and nutritional values of a locally collected Korean corn line with high tillering and earing characteristics were investigated at plant densities from 2778 to 8333 plants/ l0a. This line and a non-tillering and nonprolific corn as a check were grown at four plant densities and at three planting dates. The Korean local line abbreviated as MET had the highest dry matter per l0a. The highest dry matter of the MET line compared with the check hybrid was due to the highest dry leaf weight of the MET line. The highest dry leaf weight of the MET line was due to the increased number of tillers of the MET line. Other plant parts such as ear weight, kernel weight and cob weight of the MET line were lower than those of the check hybrid. The dry husk weight per l0a of the MET line was higher than that of the check hybrid, probably due to the increased number of ears in the MET line. The total embryo production per 10 a of the MET line was significantly higher than that of the check hybrid. The increased portion of embryo of the MET line is probably responsible for the higher TON values of the MET line. No interaction between variety x planting dates or planting density was found, indicating that the MET line and check hybrid were both the same in effects of planting dates and densities. Both line and hybrid showed the highest dry matter production when the planting density was high and planting dates was early. When silage was made from either MET line or check hybrid the nutritional values in terms of crude protein, crude fat, fiber, and ash contents of the MET line were similar to those of the check hybrid. But the TON of the MET line was higher than that of the check hybrid, while the OCP of the MET line lower than that of the check hybrid. Amino acid contents of the MET line were also comparable to those of the check hybrid, while lysine content of the MET line was 10% higher than that of the check hybrid.

  • PDF

Assessment of Substantial Equivalence and Environmental Risk for Event Selection of Genetically Modified Chrysanthemum (국화의 GM 이벤트 선발을 위한 실질적 동등성 및 환경위해성 평가)

  • Lim, Jin Hee;Shim, Myung Syun;Oh, Kwan Hun;Seo, Ji Yeon;Lee, Su Young;Park, Sang Kun;Shin, Hak Ki;Cho, Myoung Rae
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.517-524
    • /
    • 2014
  • As an assessment of substantial equivalence and environmental risks of branchless chrysanthemum GM lines (LeLS69, LeLS76, LeLS80) developed in Korea, we investigated their degree of branchlessness and developmental characteristics including growth and flowering, as well as the stability of populations of insect pests and soil microbes. The GM lines were compared with a control variety, 'Jinba'. LeLS80 showed the highest level of branchlessness among the three GM lines, whereas abnormal axillary buds developed in lines LeLS76 and LeLS69. There were no significant differences between the growth characteristics of 'Jinba' and the GM lines. The branchlessness LeLS80 was increased during the summer season, suggesting that it is a useful germplasm for developing elite branchless cultivars. These GM lines showed no significant differences in the occurrence of five insect pests including aphids, mites, leaf miners, thrips, and whiteflies. Similarly, for soil microbes including bacteria and actinomycetes, there were no significant differences between 'Jinba' and the GM lines. However, there was a higher occurrence of fungi in the GM lines compared to 'Jinba'. Our findings suggest that 'Jinba' and the GM lines are substantially equivalent, although further monitoring studies are needed to confirm this.

Engineering Characteristics of Wet-mixing Solidified Soil in Pavement Surfacing (습식 경화교반토 포장의 공학적 특성)

  • Yoo, Ji-Hyeung;Shu, Dong-Hyuk;Lee, Seong-Won
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.1-7
    • /
    • 2004
  • Roads, like bikeways, parkways and walks, are to be just capable of supporting light traffic and traveling public, but they are required to be human friendly and environmental-oriented. Lately soil-solidifier mixture, a kind of soil-cement, has developed and has been applied to the recycling and environment-oriented pavement as the surfacing material. Soil-solidifier pavement structure has been designed by only experience. To design this pavement mechanically, it is necessary to find out basic engineering properties of soil-solidifier mixture. This study focuses on finding out mechanical characteristics of the mixture according to mixture proportions and aging. Test molds with various mixture proportions are made, and then unconfined strength tests are performed for test molds with aging of the mixture. As the result of this study, it is found that the strength of the mixture increases with amount of cement and that maximum strength is achieved at 6%$\sim$8% of the ratio of solidifier and water. The strength increase rapidly until 14 days, after then slowly. After 28 days the strength of the mixture approaches to the constant value. The heat of hydration during curing of the mixture is measured no significantly. It also shows that temperature characteristics of the mixture is similar to that of soil. Since this mixture is mixed with soil and is able to improve engineering problems in pavement due to temperature, this mixture is expected to use effectively in the environment-oriented pavement for light traffic.

  • PDF

Performance Test of the Iterative Method and Newly Developed True X Method (PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가)

  • Choi, Jae-Min;NamKung, Chang-Kyeong;Park, Seung-Yong;Nam, Ki-Pyo;Lim, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • Objective: In this study, the differences between two reconstruction methods were analyzed by comparing image uniformity and contrast according to Iteration and Subset, which were altered through the Iterative method and True X method, used in Siemens' PET/CT studies. Methods: The Phantom images were obtained by exposure for two minutes per one bed. To determine the image uniformity, the Coefficient of variance was used. Also, in order to compare the contrast value, we measured and analyzed the ratio of the SUV mean of Phantom image's hot spheres and the background. Results: Under the same reconstruction conditions (Iteration and Subset) of CV, the Iterative method was higher than the True X method. In the comparison of the SUV mean ratio of the background and hot sphere, the True X method had a closer rate than the Iterative method. Conclusion: The newly developed True X reconstruction method is better than the previously used Iterative method in terms of uniformity and contrast. However, the date for this study was only obtained using the Phantom device. In order to obtain more accurate and useful information from the experiment, further research should be conducted. Also, it is necessary to find the appropriate standards for Iteration and Subset for further experimentation.

  • PDF